Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.

Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is the battery's terminal voltage. To accurately measure the emf, the internal resistance should be known, or the current could be made zero. However, standard voltmeters require current to operate; thus, an alternate technique is required.

A potentiometer is a null measurement device used for measuring unknown potentials more accurately than voltmeters. It consists of a voltage source connected to a long, uniform resistive wire of constantan or magnum. The battery maintains a constant current flow and a consistent potential gradient across the wire length. A rheostat is used to regulate the current across the wire. The unknown emf source is connected in series with a galvanometer and a jockey. A variable potential drop can be obtained across the wire by moving the contact to different points. In a balanced condition, the galvanometer shows zero deflection. This length is noted, and it corresponds to Rx. Next, the unknown source is replaced by a standard emf source, and the contact point is again adjusted to obtain zero deflection. This balanced length corresponds to Rs.

In both cases, as no current passes through the galvanometer, the current through the wire is the same. The ratio of the two relations gives the expression of unknown emf in terms of the resistances of the wire segments.

Equation1

With the measured resistance values, the unknown emf can be calculated. The potentiometer can also be used to measure the internal resistance of a cell or to compare the emfs of two voltage sources.

Tags
PotentiometerVoltage MeasurementCurrent MeasurementEmf MeasurementNull MeasurementInternal ResistanceResistive WireGalvanometerRheostatVoltage SourceVariable Potential DropUnknown EmfBalanced ConditionResistance CalculationElectrical Measurements

Du chapitre 27:

article

Now Playing

27.12 : Potentiometer

Direct-Current Circuits

397 Vues

article

27.1 : Force électromotrice

Direct-Current Circuits

3.7K Vues

article

27.2 : Résistances en série

Direct-Current Circuits

3.9K Vues

article

27.3 : Résistances en parallèle

Direct-Current Circuits

3.8K Vues

article

27.4 : Combinaison de résistances

Direct-Current Circuits

2.2K Vues

article

27.5 : Règles de Kirchhoff

Direct-Current Circuits

3.9K Vues

article

27.6 : Règles de Kirchoff : Application

Direct-Current Circuits

1.2K Vues

article

27.7 : Batterie CC

Direct-Current Circuits

614 Vues

article

27.8 : Sources de tension multiples

Direct-Current Circuits

958 Vues

article

27.9 : Galvanomètre

Direct-Current Circuits

2.0K Vues

article

27.10 : Ampèremètre

Direct-Current Circuits

1.9K Vues

article

27.11 : Voltmètre

Direct-Current Circuits

839 Vues

article

27.13 : Pont de Wheatstone

Direct-Current Circuits

339 Vues

article

27.14 : Puissance dissipée dans un circuit : résolution de problèmes

Direct-Current Circuits

861 Vues

article

27.15 : Circuits RC : Charge d’un condensateur

Direct-Current Circuits

3.0K Vues

See More

JoVE Logo

Confidentialité

Conditions d'utilisation

Politiques

Recherche

Enseignement

À PROPOS DE JoVE

Copyright © 2025 MyJoVE Corporation. Tous droits réservés.