Accurate intracardiac echocardiography (ICE) shows significant accuracy in estimating the left atrial structure, a prospective and promising cardiac structure estimation method. Here we propose a protocol for three-dimensional modeling of the left atrium and pulmonary veins with ICE and fast anatomical mapping (FAM) catheter remodeling.
Intracardiac echocardiography (ICE) is a novel tool for estimating cardiac anatomy during pulmonary vein isolation procedures, particularly the left atrium (LA) anatomy and pulmonary vein structures. ICE is widely used to establish a three-dimensional (3D) left atrial structural model during ablation procedures. However, it is unclear whether using ICE in a precise 3D modeling method can provide a more accurate left atrial 3D model and the transseptal approach. This study proposes a protocol to model the left atrium and pulmonary veins with ICE and fast anatomical mapping (FAM) catheter remodeling. It evaluates the accuracy of the models produced using the two methods through observer scoring. We included 50 patients who underwent ICE-based 3D remodeling and 45 who underwent FAM 3D remodeling based on pulmonary vein isolation procedures. The pulmonary vein antrum remodeling is estimated by comparing the antrum area acquired by remodeling and left atrial computed tomography angiography (CTA). The observer scores for the modeling in the ICE and FAM groups were 3.40 ± 0.81 and 3.02 ± 0.72 (P < 0.05), respectively. The pulmonary vein antrum area obtained using the ICE- and FAM-based methods showed a correlation with the area acquired by left atrium CT. However, the 95% confidence interval bias was narrower in ICE-acquired models than in FAM-acquired models (-238 cm2 to 323 cm2 Vs. -363 cm2 to 386 cm2, respectively) using Bland-Altman analysis. Therefore, precise ICE possesses high accuracy in estimating the left atrial structure, becoming a promising approach for future cardiac structure estimation.
Atrial fibrillation (AF) is commonly associated with atrial remodeling, including mechanical remodeling, electrophysiologic remodeling, and structural remodeling1. Structural remodeling will dramatically affect the anatomy of the atrium. Hence, assessing the left atrial anatomy in AF patients is essential for AF ablation procedures and any procedure targeting the left atrium. For the FAM 3D modeling, the 3D modeling of the heart is reconstructed based on the spatial position change of its position corresponding to the fixed magnetic field by continuously displacing the magnetic catheter in the heart. In contrast, ICE 3D modeling integrates the ....
This research procedure closely adhered to the rules of human research ethics committee of China-Japan Union Hospital of Jilin University. Patients who underwent radiofrequency ablation of atrial fibrillation were searched on the Carto system (3D mapping system). Then, the PACS system was used to determine whether the patient underwent left atrial CT examination before surgery to ascertain that each selected patient had left atrial CT images for comparison. Soundstar is the ICE catheter used in this study, and a Cartosou.......
From January 2021 to June 2022, we selected 114 patients who underwent radiofrequency ablation of atrial fibrillation at our hospital. Patients were excluded based on the following criteria: no 3D volume reconstruction image of left atrial CT (n = 11), no transseptal puncture ICE image (n = 4), and incomplete reconstruction of the left atrium and pulmonary vein images (n = 4). Finally, 50 patients with ICE 3D modeling and 45 with FAM 3D modeling as control group was included in this study.
Two.......
Intracardiac echocardiography (ICE) is a noncontact three-dimensional reconstruction tool. It determines the appropriate ablation plane and reduces the incidence of pulmonary vein stenosis. Moreover, ICE improves the effectiveness of catheter ablation by assessing the distal position of the ablation catheter and its relative association with the anatomical structures. These structures include the left atrium and pulmonary vein and the diameter and morphology of the pulmonary vein.
ICE-guided a.......
We thank Junming Yan, consultant of Johnson&Johnoson, who is responsible for research grants.This work was funded by the Jilin Provincial Department of Science and Technology (20220402076GH).
....Name | Company | Catalog Number | Comments |
CARTO V6 | Johnson&Johnson | 6.0.80.45 | |
CARTO V7 | Johnson&Johnson | 7.1.80.33 | |
PACS system | Philips(China) Investment Co.,Ltd | N/A | |
Soundstar | Johnson&Johnson | N/A |