Podsumowanie

Quantitative and controlled investigations into insect biting behaviors are crucial for devising effective strategies to combat vector-borne diseases. In this context, a method for fabricating a bio-hybrid atomic force microscopy (AFM) probe is introduced.

Streszczenie

Mosquitoes, notorious as the deadliest animals to humans due to their capacity to transmit diseases, pose a persistent challenge to public health. The primary prevention strategy currently in use involves chemical repellents, which often prove ineffective as mosquitoes rapidly develop resistance. Consequently, the invention of new preventive methods is crucial. Such development hinges on a thorough understanding of mosquito biting behaviors, necessitating an experimental setup that accurately replicates actual biting scenarios with controllable testing parameters and quantitative measurements. To bridge this gap, a bio-hybrid atomic force microscopy (AFM) probe was engineered, featuring a biological stinger - specifically, a mosquito labrum - as its tip. This bio-hybrid probe, compatible with standard AFM systems, enables a near-authentic simulation of mosquito penetration behaviors. This method marks a step forward in the quantitative study of biting mechanisms, potentially leading to the creation of effective barriers against vector-borne diseases (VBDs) and opening new avenues in the fight against mosquito-transmitted illnesses.

Wprowadzenie

World Health Organization (WHO) reported that vector-borne diseases (VBDs) account for over 17% of all infectious diseases, which cause more than 7,00,000 deaths per year globally. For example, as the deadliest animal in the world, mosquitoes spread numerous pathogens, such as dengue, malaria, and Zika, through blood-feeding arthropods, resulting in 700 million infections each year1. Explorations toward the development of effective measures to prevent VBDs are of crucial importance, including mimicking the penetration behaviors of mosquitoes to investigate their biting mechanisms and studies of potential barriers to prove their efficacy in prev....

Protokół

The mosquito species used for this protocol is an uninfected adult female Aedes aegypti (A. aegypti), received frozen and stored in a -20 °C degree freezer. The species was provided by the NIH/NIAID Filariasis Research Reagent Resource Center for distribution through BEI Resources, NIAID, NIH: Uninfected Aedes aegypti, Strain Black Eye Liverpool (Frozen), NR-48920. The reagents and equipment used for the study are listed in the Table of Materials.

1. Dissecting the labium from the proboscis

  1. Using tweezers, place a dead mosquito on a glass slide under the microscop....

Reprezentatywne Wyniki

Scanning electron microscopy (SEM) images of the fabricated bio-hybrid AFM probe can be found in Figure 7. The end of the labrum was successfully glued to the tipless cantilever beam. Due to the natural curvature of mosquito stingers and the manual operation of the presented protocol, it is extremely difficult to obtain a cantilever with a stinger tip perfectly perpendicular to the cantilever. The off-center angle between the stinger and an imaginary center line perpendicular to the cantilev.......

Dyskusje

Step 1 of the protocol is meant to clean the biological sample of the unwanted labium. To achieve this, an incision is made on the labium, but not on the fascicle, which rests directly beneath the labium (Figure 1). Because the fascicle and labium are not joined together at their interface (i.e., the labium is free to slide along the fascicle and is only kept in place by its attachment to the mosquito head), the performed incision is meant to separate part of the labium from the mosquito'.......

Ujawnienia

Authors have no conflict of interest to declare.

Podziękowania

The authors acknowledge the funding support from Canada's New Frontiers in Research Fund (NFRF), Natural Sciences and Engineering Research Council of Canada (NSERC) Discovery program, and Fonds de Recherche du Québec Nature et Technologies (FRQNT) master's training scholarships. The authors also would like to thank Prof. Yaoyao Zhao's group at McGill for their technical support on 3D printing of some components.

....

Materiały

NameCompanyCatalog NumberComments
 5-SA-SE Straight Tapered Ultra Fine-Pointed TweezersExceltaN/AFor manipulating/dissecting the proboscis.
C-4D Probe stationEverbeing Int’l Corp N/AUsed for AFM assembly.
Tipless Tapping Mode CantileverNanoAndMore USATL-NCHAFM cantilever used for mounting the labrum.
Specs are shown here:

Shape: Beam
Force Constant: 42 N/m (10 - 130 N/m)
Resonance Frequency: 330 kHz (204 - 497 kHz)
Length: 125 µm (115 - 135 µm)
Width: 30 µm (22.5 - 37.5 µm)
Thickness: 4 µm ( 3 - 5 µm)
UV ExpoxyLet's resinALR00146For stinger attachment.

Odniesienia

  1. World Health Organization. Global vector control response 2017–2030. World Health Organization. , (2017).
  2. Gurera, D., Bhushan, B., Kumar, N. Lessons from mosquitoes’ painless piercing. J Mech Behav Biomed Mater. ....

Przedruki i uprawnienia

Zapytaj o uprawnienia na użycie tekstu lub obrazów z tego artykułu JoVE

Zapytaj o uprawnienia

Przeglądaj więcej artyków

Bio hybridMosquitoStingerAtomic Force MicroscopyAFM ProbeBiting MechanismQuantitative StudyVector borne DiseasesPublic HealthPreventionMosquito ResistanceControllable TestingRealistic Testing Scenarios

This article has been published

Video Coming Soon

JoVE Logo

Prywatność

Warunki Korzystania

Zasady

Badania

Edukacja

O JoVE

Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone