This protocol describes a simple method for concurrent recording of co-localized electroencephalography (EEG) and multi-laminar local field potential in an anesthetized rat. A burr hole drilled in the skull for the insertion of a microelectrode is shown to produce negligible distortion of the EEG signal.
Although electroencephalography (EEG) is widely used as a non-invasive technique for recording neural activities of the brain, our understanding of the neurogenesis of EEG is still very limited. Local field potentials (LFPs) recorded via a multi-laminar microelectrode can provide a more detailed account of simultaneous neural activity across different cortical layers in the neocortex, but the technique is invasive. Combining EEG and LFP measurements in a pre-clinical model can greatly enhance understanding of the neural mechanisms involved in the generation of EEG signals, and facilitate the derivation of a more realistic and biologically accurate mathematical model of EEG. A simple procedure for acquiring concurrent and co-localized EEG and multi-laminar LFP signals in the anesthetized rodent is presented here. We also investigated whether EEG signals were significantly affected by a burr hole drilled in the skull for the insertion of a microelectrode. Our results suggest that the burr hole has a negligible impact on EEG recordings.
It is generally accepted that LFPs recorded via microelectrodes primarily reflect the weighted sum of synchronized excitatory and inhibitory synaptic activities of local pyramidal neural populations1,2,3,4. Our recent research demonstrated that the profile of the LFP signal could be separated into components of excitation and inhibition5,6. However, as LFP is normally measured via an invasive procedure, it is not suited for most studies of the human brain.
On the other hand, EEG is a non-invasive technique for measuring the electrical activity of the brain. It is widely used as a diagnostic tool for certain types of neurological diseases such as epilepsy, and as a research tool in human cognitive studies. Despite its popularity, a major limitation of EEG is the inability to interpret its temporal profiles precisely in terms of the underlying neural signals7,8,9.
Increasingly, mathematical models of EEG are developed to enhance understanding of brain function10,11,12,13,14,15. Most of the existing EEG models are developed based on fitting frequency domain characteristics of the model predicted output to the EEG data spectrum during spontaneous activity, and very few EEG models can generate realistic sensory evoked potentials. In this context, concurrent recordings of EEG and LFP will provide important insight and constraints for developing more accurate mathematical models of EEG.
To address this need for concurrent recordings to further explore the neural origin of EEG, we developed a methodology to simultaneously record EEG and multi-laminar LFP signals in the neocortex of the anesthetized rat. The setup is similar to previous concurrent EEG/LFP studies conducted in primates16,17. We further investigated the effect of a burr hole drilled into the skull on EEG recordings surrounding the hole, by comparing bilateral EEG recordings (i.e., one hemisphere with a burr hole, the other hemisphere intact) in the absence of sensory stimulation. Our results demonstrate that concurrent EEG/LFP recordings can be conducted simply and effectively, with little EEG signal distortion from the burr hole in the skull.
All experiments were carried out in accordance with the British Home Office regulations (Animals (Scientific Procedures) Act, 1986) and approved by the Research Ethics Committee at the University of Reading, UK.
1. Animal Preparation
NOTE: Female Lister Hooded rats were used for all experiments. This is a non-survival procedure.
2. Surgical Procedure
3. Co-localized EEG/LFP Setup
Figure 1: General setup for concurrent EEG/LFP recording. (A) The setup consists of a modified nose cone for ease of whisker pad stimulation under isoflurane anesthesia, two stimulating electrodes inserted into the whisker pad, a spider electrode positioned on the skull above the barrel cortex contra-lateral to the stimulating electrodes, a multi-channel microelectrode inserted into the barrel cortex through the spider electrode, and reference electrodes placed inside an incision at the back of the rat's neck. (B) A view through the microscope of the spider electrode securely positioned onto the skull by EEG paste. The microelectrode is inserted into a burr hole drilled into the skull under the spider electrode. The scalp is held back by surgical thread (suture) tied to the stereotaxic frame. Please click here to view a larger version of this figure.
Figure 2. A signal flow diagram. The rat is placed inside a Faraday cage. The stimulating electrodes receive commands from the stimulator box controlled by the Data Acquisition Unit through its software installed on a PC. The neural signal recorded by the microelectrode is transmitted to a pre-amplifier inside the Faraday cage. The neural signal recorded by the EEG probe is transmitted to the pre-amplifier through a signal splitter. The pre-amplifier is connected to the Data Acquisition Unit outside the Faraday cage via a fiber optic cable. The neural data are then stored on a local drive on the PC, while they can also be displayed on a PC monitor. A mobile small animal isoflurane system administers isoflurane from outside the Faraday cage. Please click here to view a larger version of this figure.
4. Electrical Stimulation and Neural Recordings
NOTE: The sampling frequency for all neural data is 24.41 kHz with 16-bit resolution. A trial consists of a single electrical stimulation at the start of the trial. Each trial lasts 10 s, which is also the inter-stimulus interval (ISI). Each stimulus is a square current pulse of 1.2 mA lasting 0.3 ms. For bilateral experiments to study the effect of the burr hole, continuous resting state of 250 s is also recorded.
Figure 3. A display of the software GUI for the Data Acquisition Unit. It allows the appropriate circuit to be uploaded, stimulation parameters to be set, and data to be recorded and visualized. Please click here to view a larger version of this figure.
Figure 4: A display of the software GUI showing a registered data directory. Please click here to view a larger version of this figure.
Figure 5: The GUI on the pre-amplifier. It allows EEG recording parameters (e.g., sampling frequency and referencing preference) to be set. Please click here to view a larger version of this figure.
5. Data Analysis
Data from 4 rats were averaged to obtain mean time series where applicable. The amplitude of the evoked EEG response, also known as the event related potential (ERP), is typically much smaller than that of the LFP. Figure 6 shows the average ERP and LFP in the supragranular, granular, and infragranular layers of the barrel cortex, respectively. The error band in each plot is the corresponding standard error. It can be seen that ERP is approximately 10 times smaller than the evoked LFP.
Figure 6: Mean (n = 4) neural signals of ERP, supragranular, granular, and infragranular LFP. Shadow indicates standard error. Please click here to view a larger version of this figure.
Comparisons of the temporal dynamics of ERP and LFP are shown in Figure 7. Direct superposition of ERP and the supragranular LFP in Figure 7A illustrates the order of amplitude differences between these two types of neural signals. To compare the temporal dynamics, both ERP and LFP are normalized with respect to their negative peak amplitude. Figure 7B and 7C show the normalized ERP superimposed with the normalized supragranular LFP and normalized granular LFP, respectively.
It can be seen from Figure 7B that the peaks of P1 and N1 for ERP are more delayed than the corresponding peaks of LFP in the supragranular layer. However, the temporal profiles of these two neural signals are similar, with P1 preceding N1. On the other hand, the temporal profile of ERP is markedly different from that of the granular (layer IV of the barrel cortex) LFP (Figure 7C). Importantly they are not mirror images of each other, with granular LFP dominated by a single negative peak (reflecting a major sink in cortical layer IV), whereas ERP consisted primarily of two peaks with opposite polarity.
Figure 7: Comparison of the temporal dynamics of ERP and LFP. (A) ERP (solid line) superimposed with supragranular LFP (dashed line). Shadow indicates standard error. (B) Normalized ERP (solid line) superimposed with normalized supragranular LFP (dashed line). (C) Normalized ERP (solid line) superimposed with normalized granular LFP (dashed line). Please click here to view a larger version of this figure.
The ERP signal was measured via a spider electrode placed on the skull with a burr hole drilled into it. To investigate the effect of the hole on EEG recordings, another spider electrode was placed on the intact skull above the ipsi-lateral barrel cortex. Care was taken to ensure that the impedances of the two spider electrodes were comparable in magnitude by adjusting the amount of EEG paste used. Data from four rats (which were not the same rats used above) are presented here.
Figure 8 shows the concurrent resting state EEG recordings from both electrodes of one rat, with 100 s data displayed in Figure 8A, and the data in the rectangular frame (20 s) are expanded in Figure 8B. The two EEG signals largely co-vary, within similar range of amplitude. Figure 9 shows the PSD of the four rats, with the top row using a linear scale on the frequency axis, and the bottom row using a logarithmic scale on the frequency axis to provide an expanded view in the lower frequency range. From Figure 9, there does not appear to be consistent bias in the PSD across subjects. This was confirmed by performing one-sample t-tests on the normalized differences in the averaged PSD in the five frequency bands, shown in Figure 10. None of the normalized PSD differences in these frequency bands were significantly different from zero (p = 0.32, 0.46, 0.85, 0.69, and 0.97, respectively).
Figure 8: Bilateral EEG recordings. (A) Skull EEG recording during resting state with a burr hole in the skull (black) and a simultaneous EEG recording on the opposite hemisphere with the skull intact (grey). (B) Expanded view of the waveforms within the rectangular frame in (A). Please click here to view a larger version of this figure.
Figure 9: Power spectral density (PSD) of the contra- (blue) and the ipsi-lateral (red) EEG. Each column shows the PSD for one rat. The top panels use linear frequency scale, while the bottom panels use logarithmic frequency scale to allow the PSD in the lower frequency range to be visualized. Please click here to view a larger version of this figure.
Figure 10: Group analysis. Normalized difference between the contra- and the ipsi-lateral PSD with the five frequency bands: Delta, Theta, Alpha, Beta, and Gamma. Each bar shows the mean normalized differences within the frequency band, with the standard error shown as the error bar. Please click here to view a larger version of this figure.
We have described an experimental procedure for concurrent recording of co-localized EEG and LFP signals of an isoflurane anesthetized rat in response to whisker pad stimulation. A microelectrode was inserted into the neocortex through an opening in the EEG spider electrode which was aligned with a burr hole drilled into the skull. The electrode was secured to the skull by a conductive and adhesive EEG paste23. The nose cone used for the administration of isoflurane was modified so that stimulating electrodes could be inserted into the whisker pad with ease.
The EEG paste was effective at mounting the spider electrode securely to the skull, while providing excellent electrical conductivity throughout the experimental day without the need for additional application of paste. It replaced the undesirable use of glue to fix the periphery of the spider electrode to the skull, as glue is non-conductive and can increase the impedance of the electrode if it runs between the skull and the electrode. EEG paste has a number of advantages over EEG gel, which is difficult to shape around the burr hole and can dry out during experiment, resulting in poor EEG signals.
As the rat was placed inside a Faraday cage, electrical noise due to the environment was greatly attenuated. However, sometimes the neural signal was still quite noisy. In most cases, this was caused by the reference electrode not securely positioned and therefore needed to be re-adjusted or more EEG paste used. Another common problem was that the evoked LFP was small in amplitude. This could be due to the microelectrode not positioned at the center of the cortical region activated by the stimulating electrodes. Instead of re-inserting the microelectrode, which could cause more damage to the local neurons, we usually adjusted the position of the stimulating electrodes in the whisker pad until a reasonable amplitude of the LFP (>3 mV) could be observed.
One of the limitations of the technique is the poor spatial resolution of the spider electrode, which has a diameter of 6 mm. This is large compared with the size of the rat's skull. Unfortunately, the spider electrode used here is the smallest available to purchase. It will be desirable to reduce the diameter of the spider electrode to 2-4 mm, thus increasing the spatial specificity of EEG recordings, making the comparison between the EEG signal and the supragranular LFP signal less ambiguous.
Several critical steps in the protocol need special attention. The first is the insertion of the microelectrode through the burr hole. As the dura is otherwise intact, the precision of the insertion is crucial. A slight resistance at the tip of the electrode usually means the electrode is not positioned correctly. It must be raised, position adjusted, and re-inserted. The second is the position of the nose cone on the rat. It must not be too loose, as isoflurane will escape from the cone. It also must not be too tight, as this can obstruct the nostrils of the rat and cause difficulty breathing. Special attention is also required to ensure that the amplitude of the EEG recording is much smaller (usually 5 to 10 times smaller) than the LFP top channel recording. If they are similar, it is an indication that the EEG probe has come into direct or indirect contact with the microelectrode. An indirect contact is usually through the cerebral spinal fluid (CSF) that sometimes fills the hole drilled in the skull. The conductivity of CSF is typically 100 times that of the skull24,25. Thus, if the level of CSF inside the burr hole is sufficiently high, it can make contact with the spider electrode. To avoid this, the hole should be frequently cleaned with super absorbent cotton sponges such as the absorption spears.
The effect of a burr hole (diameter <2 mm) in the skull on the EEG recording surrounding the hole was studied by placing another spider electrode on the intact skull atop the ipsi-lateral barrel cortex so that bilateral EEG recordings could be compared. The results shown in Figure 9 and Figure 10, suggest the effect to be insignificant at the 0.05 level of significance. Other factors affecting the amplitude of the EEG include how well the EEG paste was in contact with the skull, how firm the electrode was pressed to the paste, and the spatial extent of the EEG paste on the skull.
It is also worthwhile to note that the protocol described here recorded skull EEG, which is different from scalp EEG used in human EEG studies. The scalp acts like a resistor or a low-pass filter, which will reduce the signal-to-noise ratio of the EEG recording further.
Finally, comparison of the temporal dynamics of the ERP and that of the evoked LFP across cortical layers suggest that somatosensory evoked potential reflects better the LFP in the supragranular layer of the cortex than that in the granular and infragranular layers. This is in agreement with our earlier work6, demonstrating that the initial segment (P1) of the ERP is related to the return current arising from the inflow of the excitatory synaptic current occurring in the granular layer, while the subsequent decrease (N1) in ERP may be related to the delayed arrival of thalamic afferent to cortical layers II/III and/or feedforward signals from deeper cortical layers. In conclusion, concurrent recordings of EEG/LFP can enhance understanding of the neural genesis of EEG, and facilitate the mathematical modeling of EEG in terms of neural signals across cortical layers.
The authors have nothing to disclose.
We would like to thank Andrew Cripps and the BioResource Unit at the University of Reading. This research was funded by the BBSRC (Grant number: BB/K010123/1). Data associated with this work is freely available from Y.Z. (ying.zheng@reading.ac.uk).
Name | Company | Catalog Number | Comments |
Female Lister Hood rats | Charles Rivers | ||
Spider electrode | Unimed Electrode Supplies Ltd | SCS24-426 | |
EEG paste: Ten20 | Unimed Electrode Supplies Ltd | 10-20-S | |
Stereotaxic holder with dual micromanipulator arms: Dual Manipulator Stereotaxic Frame with 18° Ear Bars | WPI (World Precision Instruments) | 502603 | |
Isoflurane | National Vet Services Limited | 50878 | |
Hard plastic nose cone: Anasthesia Gas Mask for Rat | WPI | 502054 | |
Small animal isoflurane anaesthetic system | WPI | EZ-B800A | |
Thermostatic heating pad: Rat Blanket System 230V | Harvard Apparatus UK | 50-7221-F | |
Ophthalmic ointment: Optixcare eye lube | Viovet | 203865 | |
Lidocaine Hydrochloride (Injection 2%) | Larkmead Vets | ||
Jacquette Scaler #1SSE, 18cm, Hollow | WPI | 503421 | |
Serrated and curved dissecting forceps | WPI | 15915 | |
Braided silk, non-absorbable suture: Mersilk Suture W502H | National Vet Services Limited | 153746 | |
Dental drill: BONE MICRO DRILL SYST 230 VAC | Harvard Apparatus UK | 72-4860 | |
Sterile Saline: Sodium chloride 0.9% | Animalcare Ltd | 14K26BT | |
Drill bit #4 : Ball Mill, Carbide, #4 | Harvard Apparatus UK | 72-4958 | |
Drill bit #4 : Ball Mill, Carbide, #1/4 | Harvard Apparatus UK | 72-4962 | |
Faraday cage | Newport Corporation | VIS-FDC-3600 | |
Vibration isolation workstation: Vision IsoStation | Newport Corporation | M-VIS3660-RG4-325A | |
Oximeter Control Unit and sensor: MouseOxPlus, Starr Life Sciences Corp. | WPI | O15001 | |
Transparent soft nose cone: Microflex Non-Rebreathing Unit with a Rat Nosecone | WPI | EZ-103A | |
Stainless steel stimulating electrodes | PlasticsOne | E363/1/SPC | |
Isolated current stimulator | Made in House | ||
16-channel micro-electrode, 100 μm spacing, area of each site 177 μm2 | NeuroNexus | A1x16-10mm-100-177-A16 | |
16-channel acute headstage | Tucker David Technologies Inc., TDT | RA16AC-Z | |
Pre-Amplifier: Z-Series 64-Channel Neuro-Digitizing Preamp | TDT | PZ5-64 | |
Passive signal splitter: 32-Channel Splitter Box for PZ5 | TDT | S-BOX_PZ5 | |
Data acquisition unit: RZ2 BioAmp Processor. Z-Series 4-DSP ultra high performance processor | TDT | RZ2-4 | |
Software for Neurophysiology: OpenEX | TDT | ||
Matlab | MathWorks | ||
Absorption spears | Fine Sicence Tools | 18105-01 |