Focused ultrasound with microbubble agents can open the blood brain barrier focally and transiently. This technique has been used to deliver a wide range of agents across the blood brain barrier. This article provides a detailed protocol for the localized delivery to the rodent brain with or without MRI guidance.
Stereotaxic surgery is the gold standard for localized drug and gene delivery to the rodent brain. This technique has many advantages over systemic delivery including precise localization to a target brain region and reduction of off target side effects. However, stereotaxic surgery is highly invasive which limits its translational efficacy, requires long recovery times, and provides challenges when targeting multiple brain regions. Focused ultrasound (FUS) can be used in combination with circulating microbubbles to transiently open the blood brain barrier (BBB) in millimeter sized regions. This allows intracranial localization of systemically delivered agents that cannot normally cross the BBB. This technique provides a noninvasive alternative to stereotaxic surgery. However, to date this technique has yet to be widely adopted in neuroscience laboratories due to the limited access to equipment and standardized methods. The overall goal of this protocol is to provide a benchtop approach to FUS BBB opening (BBBO) that is affordable and reproducible and can therefore be easily adopted by any laboratory.
Despite the many discoveries in basic neuroscience, the number of emerging treatments for neurodevelopmental and neurodegenerative disorders remains relatively limited1,2. A deeper understanding of the genes, molecules and cellular circuitry involved in neurological disorders has suggested promising treatments unrealizable in humans with current techniques3. Effective treatments are often limited by the need to be brain penetrable and site-specific4,5,6,7....
All experimental procedures were done in accordance with UAB Institutional Animal Care and Use Committee (IACUC) guidelines.
1. Focused ultrasound driving equipment setup
Here, we demonstrate that focused ultrasound with microbubbles can induce localized BBB opening using the parameters specified above with both the low-power immersion transducer (Figure 3) and the FUS transducer (Figure 4). First, in early experiments, the low-power immersion transducer was targeted to one brain hemisphere either anterior (Figure 3b) or medial (Figure 3a). Animals were then sacrificed 2.......
Here we described a benchtop approach to microbubble assisted FUS BBB opening with alternative approaches including, two different transducers and methods for intracranial targeting with and without MRI guidance. Currently, in order to establish MRI-guided FUS BBB opening in the lab, there is the option to purchase excellent ready-to use devices that provide highly standardized and reproducible results with user-friendly interfaces. However, many labs are not prepared for the cost of such instruments. Therefore, the main.......
This research was supported in part by an NSF EPSCoR Research Infrastructure grant to Clemson University (1632881). In addition, this research was supported in part by the Civitan International Research Center, Birmingham, AL. The authors gratefully acknowledge the use of the services and facilities of the University of Alabama at Birmingham Small Animal Imaging Shared Facility Grant [NIH P30 CA013148]. The authors acknowledge Rajiv Chopra for his support and guidance.
....Name | Company | Catalog Number | Comments |
Bubble shaker | Lantheus Medical Imaging | VMIX | VIALMIX, actiation device used to activate Definity microbubbles |
Catheter plug/ Injection cap | SAI infusion technologies | Part Number: IC | Catheter plug/ Injection cap |
Evans blue dye | Sigma | E2129-10G | Evans blue dye |
Function generator | Tektronix | AFG3022B | Dual channel, 250MS/s, 25MHz |
FUS transducer, 1.1MHz | FUS Instruments | TX-110 | 1 MHz MRI-compatible spherically focused ultrasound transducer with a hydrophone |
Heating pad for Mice and Rats | Kent Scientific | PS-03 | Heating pad- PhysioSuite for Mice and Rats |
Infusion pump | KD Scientific | 780100 | KDS 100 Legacy Single Syringe Infusion Pump |
Kapton tape | Gizmo Dorks | https://www.amazon.com/dp/B01N1GGKRC/ ref=cm_sw_em_r_mt_dp_U_GbR7Db56HKD91 | Gizmo Dorks Kapton Tape (Polyimide) for 3D Printers and Printing, 8 x 8 inches, 10 Sheets per Pack |
Low power immersion transducer, 1MHz | Olympus | V303-SU | Immersion Transducer, 1 MHz, 0.50 in. Element Diameter, Standard Case Style, Straight UHF Connector, F=0.80IN PTF |
Magnet sets | WINOMO | https://www.amazon.com/dp/B01DJZQJBG/ ref=cm_sw_em_r_mt_dp_U_JYQ7DbM32E5QC | WINOMO 15mm Sew In Magnetic Bag Clasps for Sewing Scrapbooking - 10 Sets |
RF amplifier | E&I | A075 | 75W |
Tail vein catheter | BD | 382512/ Fisher Item: NC1228513 | 24g BD Insyte Autoguard shielded IV catheters (non-winged) |
Ultrasound contrast microbubbles | Lantheus Medical Imaging | DE4, DE16 | DEFINITY (Perflutren Lipid Microsphere) |
Ultrasound gel | Aquasonic | https://www.amazon.com/dp/B07FPQDM4F/ ref=cm_sw_em_r_mt_dp_U_D6Q7Db3J9QP7P | Ultrasound Gel Aquasonic 100 Transmission 1 Liter Squeeze Bottle |
Winged infusion sets, 22ga. | Fisher Healthcare | 22-258087 | Terumo Surflo Winged Infusion Sets |
motor controller software | N/A | N/A | custom software written in LabView for controlling the Velmex motor controller |
runtime environment for the motor controller software | National Instruments | LabView runtime engine version 2017 or better | https://www.ni.com/en-us/support/downloads/software-products/download.labview.html |
3 axis Linear stage actuator (XYZ positioner) | Velmex | ||
bolts | Velmex | MB-1 | BiSlide Bolt 1/4-20x3/4" Socket cap screw (10 pack), Qty:3 |
motor controller | Velmex | VXM-3 | Control,3 axis programmable stepping motor control, Qty:1 |
mounting cleats | Velmex | MC-2 | Cleat, 2 hole BiSlide, Qty:6 |
mounting cleats | Velmex | MC-2 | Cleat, 2 hole BiSlide, Qty:2 |
usb to serial converter | Velmex | VXM-USB-RS232 | USB to RS232 Serial Communication Cable 10ft, Qty:1 |
x-axis linear stage | Velmex | MN10-0100-M02-21 | BiSlide, travel=10 inch, 2 mm/rev, limits, NEMA 23, Qty:1 |
x-axis stepper motor | Velmex | PK266-03A-P1 | Vexta Type 23T2, Single Shaft Stepper Motor, Qty:1 |
y-axis linear stage | Velmex | MN10-0100-M02-21 | BiSlide, travel=10 inch, 2 mm/rev, limits, NEMA 23, Qty:1 |
y-axis stepper motor | Velmex | PK266-03A-P1 | Vexta Type 23T2, Single Shaft Stepper Motor, Qty:1 |
z-axis damper | Velmex | D6CL-6.3F | D6CL Damper for Type 23 Double Shaft Stepper Motor, Qty:1 |
z-axis linear stage | Velmex | MN10-0100-M02-21 | BiSlide, travel=10 inch, 2 mm/rev, limits, NEMA 23, Qty:1 |
z-axis stepper motor | Velmex | PK266-03B-P2 | Vexta Type 23T2, Double Shaft Stepper Motor, Qty:1 |
3D printable files | |||
Immersion transducer mount and pointer | https://www.tinkercad.com/things/cRgTthGXSRq | ||
Stereotaxic frame | https://www.tinkercad.com/things/ilynoQcdqlH | ||
Stereotaxic frame holder | https://www.tinkercad.com/things/aZNgqhBOHAX | ||
9.4T small bore animal MRI | Bruker | Bruker BioSpec 94/20 | ParaVision version 5.1 |
AAV9-hsyn-GFP | Addgene | ||
Cream hair remover | Church & Dwight | Nair cream | |
gadobutrol MRI contrast agent | Bayer | Gadavist (Gadobutrol, 1mM/mL) | |
Stereotactic frame | Stoelting | #51500 | not MRI compatible |
turnkey FUS delivery device | FUS Instruments | RK-300 | ready to use MRI compatible FUS for rodents |