JoVE Logo
Faculty Resource Center

Sign In

Abstract

Medicine

Användning av 3D robot ultraljud för In Vivo analys av mus njurar

Published: August 12th, 2021

DOI:

10.3791/62682

1Physiology & Biomedical Engineering, Mayo Clinic, 2Radiology, Mayo Clinic, 3Surgery, Mayo Clinic, 4SonoVol, Inc., 5Nephrology & Hypertension, Mayo Clinic
* These authors contributed equally

ERRATUM NOTICE

Important: There has been an erratum issued for this article. Read more …

Abstract

Vanliga metoder för in vivo imaging av gnagare inkluderar positron emission tomography (PET), datortomografi (CT), magnetisk resonans imaging (MRI) och ultraljud (USA). Varje metod har begränsningar och fördelar, inklusive tillgänglighet, användarvänlighet, kostnad, storlek och användning av joniserande strålning eller magnetfält. Detta protokoll beskriver användningen av 3D robot us för in vivo imaging av gnagare njurar och hjärta, efterföljande data analys och möjliga forskningsapplikationer. Praktiska tillämpningar av robotiska USA är kvantifiering av total njurvolym (TKV), liksom mätning av cystor, tumörer och vaskulatur. Även om upplösningen inte är lika hög som andra metoder, möjliggör robot-USA mer praktisk datainsamling med hög genomströmning. Med hjälp av amerikansk M-lägesavbildning kan hjärtfunktionen dessutom kvantifieras. Eftersom njurarna får 20-25% av hjärtproduktionen är bedömning av hjärtfunktionen avgörande för förståelsen av njurfysiologi och patofysiologi.

Erratum

Erratum: Use of 3D Robotic Ultrasound for In Vivo Analysis of Mouse Kidneys

An erratum was issued for: Use of 3D Robotic Ultrasound for In Vivo Analysis of Mouse Kidneys. An author name was updated, along with the Protocol and Representative Results.

The name of an author was updated from:

Ryan C. Gesser

to:

Ryan C. Gessner

Step 3.1 of the Protocol was updated from:

Turn on the US machine and the heat lamp above the US platforms. Turn on the appropriate anesthesia valves for the corresponding US bays that will be used.

to:

Turn on the US machine and the switch for the internal heating element for the US bays. Turn on the appropriate anesthesia valves for the corresponding US bays that will be used.

Figue 1 in the Representative Results was updated from:

Figure 1
Figure 1: Ultrasound system and mouse placement. (A) Diagram of ultrasound system and location of transducers. (B) View of mice in supine position on ultrasound platform with heat lamp. (C) Example of region of interest (ROI)s in place for area of interest (kidneys) with animal IDs. Please click here to view a larger version of this figure.

to:

Figure 1
Figure 1: Ultrasound system and mouse placement. (A) Diagram of ultrasound system and location of transducers. (B) View of mice in supine position on ultrasound platform. (C) Example of region of interest (ROI)s in place for area of interest (kidneys) with animal IDs. Please click here to view a larger version of this figure.

Explore More Videos

Medicin

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved