Contact hypersensitivity (CHS) is a murine experimental model of allergic contact dermatitis (ACD). CHS is based on sensitization with reactive hapten by painting the shaved skin of the chest and abdomen, with a subsequent ear skin challenge with a diluted hapten, causing a swelling reaction that is assessed in various ways.
Contact hypersensitivity (CHS) is an experimental model of allergic contact dermatitis (ACD) that can be studied in mice. This study aims to present an objective laboratory method that may help to study the CHS reaction in mice, which can be measured and quantified by various tests. To induce CHS, on day "0", mice were sensitized on a previously shaved spot by abdominal skin painting with the hapten 2,4,6-trinitrochlorobenzene (TNCB) in an acetone-ethanol mixture, whereas negative control mice were sham sensitized with vehicle alone-acetone-ethanol mixture. On day "4", the baseline ear thickness was measured with a micrometer prior to the elicitation of CHS (challenge) by painting both ears with diluted TNCB both in the test and control groups. After 24 h, the ear swelling was measured with a micrometer. CHS is an example of a T cell-mediated immune response that causes swelling in inflamed tissue, peaking 24 h after the skin challenge with the same hapten. An increase in ear edema correlated with augmented ear weight, myeloperoxidase (MPO) activity, pro-inflammatory cytokine concentration in the ear extracts, increased thickening of the edematous dermis in the histological examination, and ear vascular permeability. There was also an increase in the concentration of TNP-specific IgG1 antibodies in the sera of the test group when compared with the control mice. Additionally, CHS can be successfully transferred with the CHS-effector cells obtained from donors previously sensitized with TNCB. The CHS-effector cells were administered intravenously into naïve recipient mice, which were subsequently challenged with the same diluted hapten. Ear swelling was measured with a micrometer 24 h later.
Allergic contact dermatitis (ACD) is a common skin inflammatory disease in industrialized countries caused by a type IV hypersensitivity reaction resulting from exposure to low molecular weight chemicals called haptens. The substances causing contact sensitization in humans include heavy metal ions (chromium, nickel, iron, cobalt), turpentine, fragrances, dyes, and preservatives present in cosmetics (e.g., p-phenylenediamine), some drugs (e.g., neomycin, benzocaine), β-lactam antibiotics (i.e., penicillin), chemicals produced by plants (pentadecacatechol, a substance present in poison ivy), as well as hydroquinone-used in the photographic industry
All experiments presented in this article were conducted according to the guidelines of the 1st Local Ethical Committee on Animal Testing in Krakow. All the procedures described were performed according to the local recommendations, especially regarding using ketamine/xylazine as an anesthetic, using both sides of the ears to apply the substance/hapten, cutting off the ear, and collecting blood by eyeball removal. BALB/c (haplotype H-2d), CBA/J (H-2k), and C57BL/6 (H-2b) male and female m.......
For CHS induction, the animals were sensitized via skin painting (abdominal) with 150 µL of 5% TNCB or sham sensitized with the vehicle alone. On day "4", the ear swelling responses of both ears were induced by contact painting (challenge) with 10 µL of 0.4% TNCB in both mice previously contact sensitized with TNCB (test group) and the control group mice (sham sensitized). The presented data depict that the mice sensitized with TNCB and challenged 4 days later developed significantly increased .......
CHS is induced via haptens, which bind to self-protein antigens in the skin, creating neoantigens. CHS is mediated by local extravascular recruitment of circulating antigen-specific CHS-effector T cells, which results in swelling in the challenged tissue, peaking 24 h after exposure of the secondary skin to the same hapten6. The swelling of the tissue is mainly caused by the infiltration of leukocytes and leukocyte-dependent fibrin deposition24. These changes can b.......
This study was supported by subvention SUBZ.A020.22.060 of the Medical University in Wroclaw, Poland, and by grants from the Ministry of Science and Higher Education N N401 545940 to MS and IP2012 0443 72 to MMS.
....Name | Company | Catalog Number | Comments |
70% ethanol | Merck KGaA, Darmstadt, Germany | 65350-M | for surface disinfection |
96-well flat-bottom plates, polypropylene | Greiner Bio-One GmbH, Kremsmunster, Austria | 655101 | for MPO and Evans blue measurement - plates should be made of polypropylene, that has a lower binding capacity so proteins or DNA will not bind |
Acetone (ACS reagent, ≥99.5%) | Merck KGaA, Darmstadt, Germany | 179124 | |
Aluminum foil | Merck KGaA, Darmstadt, Germany | Z185140 | |
Analytical balance | Sartorius Weighing Technology GmbH, Goettingen, Germany | PRACTUM224-1s, 29105177 | |
Automated tissue processor | MediMeas Instruments, Sarsehri, Haryana, India | MTP-E-212 | automatically prepare tissue samples by fixing, dehydrating, clearing, and infiltrating them with paraffin |
BD Vacutainer SST II Advance (tube with gel for obtaining serum) | Becton Dickinson (BD), Franklin Lakes, NJ, USA | BD 366882 | |
Bicinchoninic acid kit for protein determination | Merck KGaA, Darmstadt, Germany | BCA1-1KT | |
Biotin Rat Anti-Mouse IgG1 | Becton Dickinson (BD Biosciences), Franklin Lakes, NJ, USA | 553441 | |
BSA (bovine serum albumine) | Merck KGaA, Darmstadt, Germany | A9418 | protein assays & analysis, 2 mg/mL |
Cell strainer, pore size 70 μm | BIOLOGIX, China | 15-1070 | suitable for 50 mL tubes |
Coverslip | VWR, Radnor, Pennsylvania, United States | 631-1583 | 24 mm, but it possible to use different size |
Disposable pipettes capacity: 5 mL, 10 mL, 25 mL | Merck KGaA, Darmstadt, Germany | Z740301, Z740302, Z740303 | |
DPBS (Dulbecco′s phosphate buffered saline) | ThermoFisher Scientific, Waltham, Massachusetts, USA | 14190144 | no calcium, no magnesium, mammalian cell culture |
DPX Mountant for histology | Merck KGaA, Darmstadt, Germany | 6522 | mounting media for H-E, might be used some other e.g, Canada balsam |
Dumont 5 tweezers - straight | Animalab, Poznan, Poland | 11251-10FST | surgical instruments for procedures on mice (should be steriled) |
Dumont 7 tweezers - bent | Animalab, Poznan, Poland | 11272-50FST | surgical instruments for procedures on mice (should be steriled) |
Eosin Y solution, alcoholic | Merck KGaA, Darmstadt, Germany | HT110116 | |
Eppendorf Safe-Lock Tubes 1.5 mL | Eppenforf, Germany | 3,01,20,086 | polypropylene |
Eppendorf Safe-Lock Tubes, 2.0 mL | Eppenforf, Germany | 3,01,20,094 | polypropylene, round bottom (the homogenization beads can easily move) |
Ethanol 100% (absolute alkohol) | Merck KGaA, Darmstadt, Germany | 1.07017 | |
Ethanol 96% | Merck KGaA, Darmstadt, Germany | 1.59010 | |
Evans blue | Merck KGaA, Darmstadt, Germany | E2129 | |
FBS (fetal bovine serum) | ThermoFisher Scientific, Waltham, Massachusetts, USA | A3160802 | |
Formalin solution, neutral buffered, 10% | Merck KGaA, Darmstadt, Germany | HT501128 | |
Formamide 99.5% (GC) | Merck KGaA, Darmstadt, Germany | F7503 | |
Freezer -20 °C | Bosch, Germany | GSN54AW30 | |
Fridge +4 °C / freezer -20 °C | Bosch, Germany | KGV36V10 | mammalian Cell Culture, qualified, Brazil, 10 x 50 mL |
Glass microskope slides, SuperFrost Plus | VWR, Radnor, Pennsylvania, United States | 631-0108, 631-0446, 631-0447, 631-0448, 631-0449 | Slides that eliminates the need to apply adhesive materials or protein coatings, to preventing any tissue sections loss during staining. |
Graph Pad Prism | GraphPad Software Inc. | v. 9.4.0 | |
Grey soap | Pollena Ostrzeszów, Producent Chemii Gospodarczej Sp. Z.o.o. , Sp. K., Poland | Bialy jelen soap bar | grey Soap Bar Natural Hypoallergenic. Generally available product |
H2SO4 (sulfuric acid) 1 mol/l (1 M) | Merck KGaA, Darmstadt, Germany | 1.60313 | |
Harris hematoxylin solution | Merck KGaA, Darmstadt, Germany | HHS16 | |
Hemocytometer | VWR, Avantor, U.S.A | 612-5719 | manual counting chamber is recommend, which is more accurate |
Hexadecyltrimethylammonium bromide | Merck KGaA, Darmstadt, Germany | H5882 | |
Homogenizer | QIAGEN Hilden, Germany | Tissue Lyser LT, SN 23.1001/05234 | homogenizer with stainless steel beads (diameter 5 mm) for 2 mL centrifuge tubes |
Horseradish peroxidase streptavidin (HRP streptavidin) | Vector Laboratories, Inc., Burlingame, CA, USA | SA-5004-1 | |
Hydrogen peroxide solution (H202) | Merck KGaA, Darmstadt, Germany | H1009 | |
Incubator Heracell 150i | Thermo Electron LED Gmbh, Germany | 41071068 | 37 oC in the atmosphere of 5 % CO2, and 65 0C for deparaffinization the sections for histology |
Ketamine 100 mg/mL, solution for injection | Biowet Pulawy Sp. z o.o., Pulawy, Poland | cat.# not avaliable | |
KH2PO4 (potassium dihydrogen phosphate) 99.995% anhydrous basis | Merck KGaA, Darmstadt, Germany | 1.05108 | |
Laboratory Centrifuge | Heraeus Megafuge 1.0R, Thermo Scientific, Germany | B00013899 | speed to 300 x g, with cooling to 4 0C |
Laboratory Centrifuge | Heraeus Fresco 21, Thermo Scientific, Germany | 75002425 | speed to 3,000 x g, with cooling to 4 0C |
Mask (FFP2) | VWR, Radnor, Pennsylvania, United States | 111-0917 | for working with ortho-dianisine dihydrochloride |
Mice | Breeding unit of the Chair of Biomedical Sciences, Faculty of Health Sciences, Jagiellonian University Medical College, Krakow, Poland | CBA/J, C57BL/6 | |
Micrometer | Mitutoyo, Tokyo, Japan | 193-111 | digit Outside Micrometer, Ratchet Stop, 0-25mm Range, 0.001mm Graduation, +/-0.002mm Accuracy, https://shop.mitutoyo.pl/web/mitutoyo/pl_PL/all/all/Mikrometr%20analogowy%20/PR/193-111/index.xhtml |
microplate, 96 well, microlon, high binding (for ELISA test) | Greiner Bio-One GmbH, Kremsmunster, Austria | 655061 | with maxi-sorp binding surfaces for reliable and reproducible results in colormetric assays |
Microscope with objectives | Leica Microsystems CMS GmbH, Germany | DM1000, 294011-082007 | histology presented in the paper was performed under ThermoFisher Scientific EVOS M5000 Imaging System, with objectives: FL 20X LWDPH, 0.40NA/3.1WD and FL 40X LWDPH 0.65NA/1.79WD |
Myeloperoxidase from human leukocytes (MPO standard) | Merck KGaA, Darmstadt, Germany | M6908 | |
Na2HPO4 x 7 H2O (sodium phosphate dibasic heptahydrate) | Merck KGaA, Darmstadt, Germany | S9390 | |
Olive-oil | Merck KGaA, Darmstadt, Germany | 75343 | pure, natural |
OptEIA Mouse IFN-γ ELISA Set | Becton Dickinson (BD Biosciences), Franklin Lakes, NJ, USA | 555138 | |
Ortho-dianisine dihydrochloride | Merck KGaA, Darmstadt, Germany | D3252 | |
Paraffin wax | Merck KGaA, Darmstadt, Germany | 76242 | beads, waxy solid |
PBS (phosphate buffered saline) | ThermoFisher Scientific, Waltham, Massachusetts, USA | 20012027 | pH 7.2, mammalian cell culture |
ph meter | Elmetron, Poland | CP-401 | |
Pipettes, variable volume with tips | Merck KGaA, Darmstadt, Germany | EP3123000900-1EA | 3-pack, Option 1, 0.5-10 uL/10-100 uL/100-1000 uL, includes epT.I.P.S. |
Razor blade | VWR, Radnor, Pennsylvania, United States | PERS94-0462 | scraper and cutter blades, single edge, aluminium spine, 100 blades per box, individually wrapped |
Rotary microtome | MRC Laboratory-Instruments, Essex, CM20 2HU UK | HIS-202A | |
Scissors - straight, sharp / sharp | Animalab, Poznan, Poland | 14060-10FST | Surgical instruments for procedures on mice (should be steriled) |
Screw cap (open top) | Merck KGaA, Darmstadt, Germany | 27056 | black polypropylene hole cap, for use with 22 mL vial with 20-400 thread |
Spectrophotometer | BioTek Instruments, U.S.A | 201446 | universal microplate spectrophotometer: λ range: 200 - 999 nm, absorbance measurement range: 0.000 - 4.000 Abs |
Staining dish 20 slides with rack | Merck KGaA, Darmstadt, Germany | S6141 | e.g. 20 slide staining dishes complete with covers, slide rack and handle |
Sterile Disposable Biopsy Punch 6mm | Integra LifeSciences, Princeton, NJ, USA | 33-36 | |
Surgical scissors | Animalab, Poznan, Poland | 52138-46 | surgical instruments for procedures on mice (should be steriled) |
Tissue processing cassettes | Merck KGaA, Darmstadt, Germany | Z672122 | tissue processing/ embedding cassettes with lid |
TMB Substrate Reagent Set | Becton Dickinson (BD Biosciences), Franklin Lakes, NJ, USA | 555214 | |
TNCB (2,4,6-trinitrochlorobenzene) | Tokyo Chemical Industry CO., LTD, Japan | C0307 | |
TNP-BSA (bovine serum albumin conjugated with 2,4,6-trinitrophenyl) | Biosearch Technologies LGC, Petaluma, CA, USA | T-5050 | |
T-PER (tissue protein extration reagent) | ThermoFisher Scientific, Waltham, Massachusetts, USA | 78510 | |
Tubes 15 mL sterile | Merck KGaA, Darmstadt, Germany | CLS430055 (Corning) | polypropylene, conical bottom |
Tubes 50 mL, sterile | Merck KGaA, Darmstadt, Germany | CLS430290 (Corning) | polypropylene, conical bottom |
Tween 20 | Merck KGaA, Darmstadt, Germany | P1379 | |
Vials, screw top, clear glass (vial only) 22 mL | Merck KGaA, Darmstadt, Germany | 27173 | for the preparation of hapten, screwed on so that it does not evaporate |
Water bath | AJL Electronic, Poland | LW102 | |
Wax (paraffin) dispenser | VWR, Radnor, Pennsylvania, United States | 114-8737 | |
Xylazine (xylapan 20 mg/mL) solution for injection | Vetoquinol Biowet Sp. z o.o., Gorzow Wielkopolski, Poland | cat.# not avaliable | |
Xylene (histological grade) | Merck KGaA, Darmstadt, Germany | 534056 |