Here, we describe a micro-drive design, surgical implantation procedure, and post-surgery recovery strategy that allow for chronic field and single-unit recordings from multiple brain regions simultaneously in juvenile and adolescent mice across a critical developmental window from postnatal day 20 (p20) to postnatal day 60 (p60) and beyond.
In vivo electrophysiology provides unparalleled insight into the sub-second-level circuit dynamics of the intact brain and represents a method of particular importance for studying mouse models of human neuropsychiatric disorders. However, such methods often require large cranial implants, which cannot be used in mice at early developmental time points. As such, virtually no studies of in vivo physiology have been performed in freely behaving infant or juvenile mice, despite the fact that a better understanding of neurological development in this critical window would likely provide unique insights into age-dependent developmental disorders such as autism or schizophrenia. Here, a micro-drive design, surgical implantation procedure, and post-surgery recovery strategy are described that allow for chronic field and single-unit recordings from multiple brain regions simultaneously in mice as they age from postnatal day 20 (p20) to postnatal day 60 (p60) and beyond, a time window roughly corresponding to the human ages of 2 years old through to adulthood. The number of recording electrodes and final recording sites can be easily modified and expanded, thus allowing flexible experimental control of the in vivo monitoring of behavior- or disease-relevant brain regions across development.
The brain undergoes large-scale changes during the critical developmental windows of childhood and adolescence1,2,3. Many neurologic and psychiatric diseases, including autism and schizophrenia, first manifest behaviorally and biologically during this period of juvenile and adolescent brain development4,5,6. While much is known regarding the cellular, synaptic, and genetic changes that occur across early development, comparatively little is known regarding how circuit- or network-level processes change throughout this time window. Importantly, circuit-level brain function, which ultimately underlies complex behaviors, memory, and cognition, is a non-predictable, emergent property of cellular and synaptic function7,8,9,10. Thus, to fully understand network-level brain function, it is necessary to directly study neural activity at the level of an intact neural circuit. In addition, to identify how brain activity is altered throughout the progression of neuropsychiatric disorders, it is critical to examine network activity in a valid disease model during the specific temporal window when the behavioral phenotypes of the disease manifest and to track the observed changes as they persist into adulthood.
One of the most common and powerful scientific model organisms is the mouse, with large numbers of unique genetic strains that model neurodevelopmental disorders with age-dependent onset of the behavioral and/or mnemonic phenotypes11,12,13,14,15,16,17,18,19,20,21. While it is challenging to correlate precise developmental time points between the brains of humans and mice, morphological and behavioral comparisons indicate that p20-p21 mice represent the human ages of 2-3 years old, and p25-p35 mice represent the human ages of 11-14 years old, with mice likely reaching the developmental equivalent of a human 20 year old adult by p603,22. Thus, to better understand how the juvenile brain develops and to identify how the neural networks of the brain become dysfunctional in diseases like autism or schizophrenia, it would be ideal to directly monitor brain activity in vivo in mice across the ages of 20 days to 60 days old.
However, a fundamental challenge in monitoring brain activity across early development in mice is the small size and relative weakness of juvenile mice. The chronic implantation of electrodes, which is necessary for longitudinal studies of brain development, typically requires large, bulky housing to protect the fine electrode wires and interface boards23,24, and the implants must be firmly attached to the mouse skull, which is thinner and less rigid in young mice due to reduced ossification. Thus, virtually all studies of in vivo rodent physiology have been performed in adult subjects due to their relative size, strength, and skull thickness. To date, most studies exploring in vivo juvenile rodent brain physiology have been performed in wild-type juvenile rats, which necessarily limits the ability to experimentally monitor juvenile brain function in a freely behaving model of a human disorder25,26,27,28,29,30.
This manuscript describes novel implant housing, a surgical implantation procedure, and a post-surgery recovery strategy to chronically study the long-term (up to 4 or more weeks) in vivo brain function of juvenile mice across a developmentally critical time window (p20 to p60 and beyond). The implantation procedure allows for the reliable, permanent affixation of the electrodes to the skulls of juvenile mice. Furthermore, the micro-drive design is lightweight, as this micro-drive weighs ~4-6 g when fully assembled, and due to the minimal counterbalancing required to offset the weight of the implant, it does not impact the behavioral performance of juvenile mice during typical behavioral paradigms.
The present study was approved by the University of Texas Southwestern Medical Center Institutional Animal Care and Use Committee (protocol 2015-100867) and performed in compliance with both institutional and National Institute of Health guidelines. The C57/Bl6 male and female mice used in the present study were implanted at p20 (weight 8.3-11.1 g at the time of implantation).
1. Micro-drive design and construction
2. Surgical implantation
3. Post-surgery recovery
The above-described protocol was used to record local field potential signals and single units from multiple brain areas simultaneously in mice, with daily recordings conducted in the same mice from p20 to p60. Reported here are representative electrophysiological recordings from two mice and post-experiment histology demonstrating the final recording locations.
Surgical implantation of the micro-drive into p20 mice
A micro-drive (Figure 1) was constructed (Figure 2) and surgically implanted into a p20 mouse, as described above. Immediately following the surgery, the mouse was attached to the counterbalance system (Figure 2G-I) and allowed to recover. Once the mouse was fully mobile, the micro-drive was plugged into an in vivo electrophysiology recording system. The cables connecting the micro-drive to the recording equipment were suspended above the mouse. Electrophysiological recordings (32 kHz) were obtained across all the channels for 1 h while the mouse behaved naturally in its home cage. Following the recording, the mouse was unplugged from the recording system, reattached to the counterbalance system, and returned to the vivarium with free access to water and chow.
Daily recording of neural activity
Electrophysiological recordings were obtained daily for several weeks to enable the chronic monitoring of the same brain region across the critical developmental windows of p20-p60. Sample raw local field potentials (LFP) from across the chronic recordings are shown in Figure 3A,C. Isolated single units were simultaneously obtained from multiple tetrodes (Figure 3B). Units with similar waveforms were identified across multiple days (Figure 3B, middle and right), but due to the potential drift of the recording electrode, it was not possible to definitively claim that the same unit was being identified across days. In a separate mouse implanted at p20 and recorded daily for several weeks, neural activity was examined on a tetrode targeting dorsal area CA1. Large-amplitude ripples and well-isolated single units were identified on each day of the recording (Figure 4).These data indicate that stable, high-quality in vivo electrophysiological recordings could be from the same mouse across early development.
Histological confirmation of the recording sites and the developmental impact of chronic implantation
Following the final recording day, the mouse was thoroughly anesthetized via isoflurane anesthesia followed by a lethal injection of pentobarbital sodium, and a current was passed through the electrode tips to produce small lesions at the recording sites. Post-experiment histological sectioning of the mouse brain allowed the visualization of the final recording sites (Figure 5A,B). In a separate cohort, three male and three female mice were surgically implanted at p20 as described above. Equal numbers of littermates were left unimplanted and maintained in identical housing conditions. The mice were sacrificed at p62 (6 weeks post-surgery for the implanted cohort). The skulls were carefully cleaned, and external measurements were taken of the bregma-to-lambda distance (Figure 5C, top left) and external maximal skull width at lambda (Figure 5C, top right). An incision was made along the midline of the skull, and one-half of the skull was removed to excise the brain for mass measurement (Figure 5C, bottom right). The height of the skull cavity at bregma was measured from the intact skull half (Figure 5C, bottom left). No measure was significantly different between the implanted and unimplanted cohorts (Wilcoxon rank-sum test), indicating that long-term implantation, starting at p20, has no gross impact on the natural development of the skull or brain volume.
Figure 1: Micro-drive components. Three-dimensional renderings of the (A) micro-drive body, (B) cannula, (C) cone, (D) lid, (E) screw attachments, and (F) tetrode-advancing screw. The critical features of each component are indicated. Measurement details can be extracted from the model files available at https://github.com/Brad-E-Pfeiffer/JuvenileMouseMicroDrive/. Please click here to view a larger version of this figure.
Figure 2: Micro-drive construction. (A) Side and (B) top view of the tetrode-advancing screw with the top and bottom screw attachments connected. (C) Side and (D) top view of the micro-drive with the body and cannula attached and the large polyimide tubing running through each cannula hole and trimmed to the bottom of the cannula. (E) Side view of the micro-drive with the screws and small polyimide tubing in place. The tops of the small polyimide tubes are trimmed immediately prior to tetrode loading. (F) Completed micro-drive attached to the stereotaxic apparatus. The protective cone that would normally surround the micro-drive has been removed for visualization purposes. Note that some of the screw attachments were printed in a black resin for this micro-drive. (G) Counterbalance support system. (H)Side and (I) top view of a mouse cage with the counterbalance support system attached. Please click here to view a larger version of this figure.
Figure 3: Representative electrophysiological recordings. A p20 mouse was implanted with a micro-drive as described above. Starting on p21 and every day thereafter for 2 weeks, the mouse was attached to the recording apparatus, and neural activity was recorded for at least 1 h. (A) Raw local field potential (LFP) recordings from the bilateral (L = left; R = right) anterior cingulate cortex (ACC), hippocampal area CA3 (CA3), and hippocampal area CA1 (CA1). The data were collected every day; for clarity, only data from odd days are displayed. All traces were taken during periods of immobility in the home cage. Scale bar: 1 mV, 2 s. (B) Representative single units isolated from hippocampal area CA3 (left) and CA1 (right) for the recordings in panel A. All the raw waveforms on each electrode are shown in black; the average is in red. Scale bar: 50 µV, 0.2 ms. (C) Representative raw LFP traces for every 10th day until the final recording day at p60 for a second mouse implanted at p20. The data were collected every day; for clarity, only data from every 10th day are displayed. All the traces were taken during periods of immobility in the home cage. Scale bar: 1 mV, 2 s. Please click here to view a larger version of this figure.
Figure 4. Stability of the chronic recordings. A p20 mouse was implanted with a micro-drive, as described above. Starting on p21 and thereafter for 4 weeks, the mouse was attached to the recording apparatus, and neural activity was recorded for at least 1 h. Shown are data from the tetrodes targeting dorsal hippocampal CA1. (A) Raw (top) and ripple-filtered (bottom) LFP for identified ripple events at p21, p30, and p40. To identify ripple events, the raw LFP was band-pass filtered between 125 Hz and 300 Hz, and the ripple events were identified as transient increases in the ripple-band power greater than 3 standard deviations above the mean. The start and end of each ripple were defined as the point when the ripple band power returned to the mean. The identified ripples are shown in red. Scale bar: 100 ms, top-to-bottom: 1,000 µV, 140 µV, 1,800 µV, 180 µV, 9,000 µV, 1,200 µV, 10,000 µV, 1,000 µV. (B) A representative single unit from each day from the CA1-targeted tetrode for the recordings in panel A. All raw waveforms on each electrode are shown in black; the average is in red. Scale bar 0.2 ms, top-to-bottom: 50 µV, 100 µV, 100 µV. (C) Autocorrelogram of all spikes for single units in panel B. These data demonstrate stable electrode placement within the hippocampal pyramidal layer across several weeks. Please click here to view a larger version of this figure.
Figure 5: Representative histology and impact on skull development. A p20 mouse was implanted with a micro-drive, as described above. Following the final recording day on p60, electrolytic lesions were produced at the recording sites, and the brain was perfused with 4% paraformaldehyde. To identify the recording sites, 50 µm sections were produced. (A) Lesions in CA1 and CA3 of the hippocampus. The arrowhead denotes the CA3 recording site; the double-arrowhead denotes the CA1 recording site. Scale bar: 0.5 mm. (B) Lesions in the bilateral ACC. The arrowheads denote the ACC recording sites. Scale bar: 0.5 mm. (C) Skull size and brain mass measurements of p62 mice implanted with a micro-drive at p20 (gray) and unimplanted littermates (white). The p-value of the Wilcoxon rank-sum test is reported for each measurement. Please click here to view a larger version of this figure.
Modern experiments exploring in vivo neural circuit function in rodents often utilize extracellular electrophysiology via permanently implanted electrodes to monitor the activity of individual neurons (i.e., single units) or local populations (via local field potentials, LFP), but such methods are rarely applied to juvenile mice due to technical challenges. This manuscript describes a method for obtaining in vivo electrophysiological recordings in mice across the developmentally critical windows of p20 to p60 and beyond. This methodology involves a manufacturing process for the printing and construction of a micro-drive implant, a surgical implantation procedure, and a post-surgery recovery strategy, all of which are specifically tailored for use in juvenile mice. Several considerations were influential in the development of this protocol, including the small size and relative weakness of juvenile mice compared to their adult counterparts, as well as the reduced ossification of the juvenile mouse skull onto which the micro-drive needed to be attached.
Two primary methods commonly used to perform in vivo electrophysiology are arrays of electrodes (e.g., tetrodes) and silicon probes. Silicon probes are lightweight, can provide a large number of recording sites per unit weight, and have been previously utilized in juvenile rats25. However, silicon probes are relatively expensive per unit. In contrast, the micro-drive described in this manuscript can be constructed using less than $50 USD in raw materials, making it a cost-effective option for in vivo recording. In addition, silicon probes must often be implanted in fixed lines, which prohibits the recording of spatially diverse brain regions. In contrast, the micro-drive design described in this manuscript utilizes independently adjustable tetrodes to accommodate simultaneous recordings in up to 16 different locations with virtually no restriction on the spatial relationship between those locations. This micro-drive design can be easily modified to allow for targeting different locations than those described here by moving the cannula hole extrusions to any desired anterior/posterior and medial/distal location. When targeting alternate brain areas, it is important to note that while the tetrodes will often travel straight, it is possible for these thin wires to deflect slightly as they exit the micro-drive cannula. Thus, the smaller or more ventral a brain region is, the more challenging it will be to successfully target the area with tetrodes.
The micro-drive implant described in this manuscript is foundationally similar to several prior tetrode-based micro-drive designs23,32,33,34,35 in that the individual tetrodes are affixed to screws, which allow for the fine control of the recording depth of each tetrode. While several features of the current micro-drive design are unique, including the ease of targeting spatially distributed brain areas, the primary novelty of the current manuscript is the description of surgical implantation and post-surgery recovery strategies, which allow for chronic studies of network activity in still-developing juvenile mice. Indeed, the surgery and recovery methodologies described here could be adapted to support other implants in juvenile mice.
To maintain a consistent recording across multiple days, the wires or probes must be rigidly affixed to the skull. While the overall structure of the mouse skull undergoes only minor changes after p20, the skull thickens considerably between ages p20 and p4536. Indeed, the skull at p20 is insufficiently rigid to support an attached implant without being damaged. To overcome this biological limitation, this protocol artificially thickens the skull via cyanoacrylate during the implantation surgery. Implantation in mice younger than p20 is likely possible using this strategy, but the mouse skull undergoes considerable size and shape changes until roughly p2036. Thus, implantation for extended periods in mice younger than p20 is not recommended as the cyanoacrylate and fixed bone screws in the still-developing skull may significantly impact the natural growth of the skull and the underlying brain tissue development. Importantly, in this study, no impact on the gross measurements of the skull or brain size was observed following chronic implantation starting at p20 (Figure 5C).
A critical step in the method described in this manuscript is the post-surgery recovery strategy; according to this strategy, the weight of the implant should be continuously counterbalanced as the mouse matures and undergoes muscular and musculoskeletal system development. Early after implantation, mice are unable to successfully bear the weight of the implant without the counterbalance, leading to malnourishment and dehydration as the mouse cannot adequately reach the food and water sources in its cage. The counterbalance system is easy and inexpensive to construct, trivial to implement, and allows mice of any implantable age to freely explore the entirety of their home cage, thus ensuring adequate nutrition and hydration. As mice age, the amount of counterbalance can be lessened until it can be entirely removed in adult mice; however, the continued use of the counterbalance system is recommended for the duration of the experiment with at least a nominal counterweight attached at all times. While an adult mouse may be able to bear the size and weight of the micro-drive over time, continued natural movement during free behavior with no ameliorating counterweight produces torque and shearing force on the bone screws that anchor the micro-drive onto the skull, making it increasingly likely to become detached, especially during longer chronic experiments.
Two important limitations are of note for the current study. First, to assess the impact of implantation at p20 on skull and brain development, several cohorts of mice were sacrificed after prolonged implantation (Figure 5C). While these analyses revealed no significant impact of implantation on the skull cavity size or brain mass (Figure 5C), the current study did not examine the skull size or brain mass at multiple time points throughout the early developmental period of p20-p60. While prior work demonstrates that the development of the brain cavity is completed by p2036, it is possible that implantation at this early window may produce unanticipated changes that are corrected or compensated for by the adult ages that were evaluated here. Second, the experiments that produced the electrophysiological data shown in Figure 3 and Figure 4 were not designed to maximize the cell yield. Thus, while the data presented here demonstrate stable, chronic recordings and well-isolated single units, they should not be taken as representative of the maximal potential yield for this device.
Many human neurological and psychiatric disorders manifest during periods of early development or across adolescence, including autism and schizophrenia. However, little is known regarding the circuit-level dysfunction that may underlie these diseases, despite the plethora of mouse models available. The identification of these initial network changes is critical for creating early detection strategies and treatment paradigms. Yet, due to technical challenges, it remains unclear how network function is disrupted across development in mouse models of neuropsychiatric diseases. The micro-drive and recovery strategy described here is designed to support investigations into multi-regional brain network development in the mouse brain and, thus, allow researchers to measure healthy brain development as well as identify alterations to that development in mouse models of disease.
This work was supported by National Institutes of Health R01 NS104829 (B.E.P.), R01 MH117149 (L.J.V.), and F99NS12053 (L.D.Q.) and the UT Southwestern GSO Endowment Award (R.J.P. and L.D.Q.). The authors thank Jenny Scaria (Texas Tech University Health Sciences Center School of Pharmacy) for technical assistance and Dr. Brendon Watson (University of Michigan) for methodological suggestions.
Name | Company | Catalog Number | Comments |
10 V video tracking LEDs | Neuralynx | HS-LED-Red/Green-omni-10V | For use with headstage pre-amplifiers that contain LED sockets for movement tracking purposes |
16TT EIB Board | Neuralynx | EIB-36-16TT | Electronic interface board- omnetics connector |
16TT headstage pre-amplifier | Neuralynx | HS-36-LED | Omnetics 44 socket signal amplifier between EIB board and tether cable for recording applications; includes connectors for headstage LEDs for movement tracking purposes |
Baby-Mixter hemostat | FST | 13013-14 | Fine curved hemostat |
Bone anchor screw | Stoelting | 51457 | Used to attach EIB board to main drive body |
Burpenorphine | ZooPharm | Lot #BERLAB0.5-221207 | Burpenorphine (0.5 mg/mL) 5mL quantity |
Cable tether | Neuralynx | HS-36 Litz Tether | Lightweight shielded wire tether for omnetics headstages; length options of 1 m/2 m/3 m/5 m |
Carprofen/Rimadyl | Bio-Serve | MD150-2 | Post-operative anti-inflammatory agent |
Clear resin v4 | Formlabs | FLGPGR04 | Liquid resin that is photopolymerized by 3D printer during the 3D printing process |
Custom (shuttle) screw | Advanced Machining and Tooling, Inc. | Custom | Machined and threaded custom screws |
Dental acrylic liquid component | Teets denture material | Lot# 329801 | liquid component of denture material (see above) |
Dental acrylic powder component | Teets denture material | Lot# 583987 | "cold cure" denture material, methyl methacrylate; mixed with liquid component for application to secure recording device in place |
DietGel Boost | ClearH2O | 72-04-5022 | High calorie dietary supplement for young/recovering mice |
Digital Lynx 16SX | Neuralynx | DigitalLynx 16SX Base | Main recording apparatus with 16 combo board slots for up to 512 recording channels |
Dissector scissors- heavy blades | FST | 14082-09 | Various |
Dumont #5 ceramic coated forceps | FST | 11252-50 | Tetrode handling/threading/pinning |
Dumont #5SF forceps | FST | 11252-00 | Multipurpose assembly use |
Dumont #5SF forceps | FST | 11252-00 | Multipurpose surgical use |
Dumont #7 fine forceps (curved) | FST | 11274-20 | Various |
Dumont #7 fine forceps (curved) | FST | 11274-20 | Multipurpose surgical use |
EIB-36 plating adapter | Neuralynx | EIB-36 plating adapter | Plating/assembly use |
EIB-36 plating adapter | Neuralynx | EIB-36 plating adapter | Stereotactic accessory for lowering drive onto skull during surgery |
Euthasol | Virbac | 710101 | Pentobarbital sodium for euthanasia |
Extra fine Bonn scissors | FST | 14083-38 | Various |
Extra fine graefe forceps | FST | 11150-10 | Small straight serrated forceps |
Extra fine graefe forceps | FST | 11150-10 | Small straight serrated forceps |
Fine hemostats | FST | 13006-12 | Fine hemostats |
Fine scissors- CeramaCut | FST | 14958-09 | Tetrode cutting |
Fine scissors- ToughCut | FST | 14058-09 | Various |
Form 3+ | Formlabs | PKG-F3-P-WS-SVC-BASIC | 3D printer for fabrication of all printed parts/materials; low-force stereolithography 3D printer (LFS) |
Gel super glue | Loctite | 1363589 | Various steps |
Graefe forceps | FST | 11049-10 | Small angled serrated forceps |
Ground wire | A-M Systems | Lot# 582335 | Stainless steel bare wire, .005" diameter, annealed, 100 feet |
Hair removal gel | Generic | Commercially available | For pre-op removal of hair from top of mouse head |
Heat gun | Dewalt | D26960K | Tetrode fusion following spinning |
High temperature cautery kit | FST | 18010-00 | For use with bone wax if applicable |
Hot bead sterilizer | FST | 18000-45 | Electrical sterilization apparatus for ad hoc instrument sterilization during surgical procedures |
Isoflurane | Covetrus | 11695067771 | Standard isoflurane liquid anesthsia for use in isoflurane vaporizer to max 5% |
Isopropyl alcohol 91% | Generic | Commercially available | For standard pre-operative sterilization procedure |
Jewelry screw (bone screws for juvenile mice) | Component supply co. | MX-000120-02SFL | S/S machine screw #000-120 x 1/8'' filister head, slotted drive |
LaGrange scissors | FST | 14173-12 | Various |
Large polyimide tubing | Nordson medical | Lot # 13564 | Polyimide tubing- inner diameter 0.0071"; outer diameter 0.0115"; length 36" |
Liquid super glue | Loctite | 1365882 | Various steps |
Micro drill | Foredom | K.1070 | K.1070 high speed rotary micromotor kit; with control box, 3/32" collet, variable speed foot control, handpiece cradle; stereotactically fittable; 100–115 V use |
Micro drill burr (0.5 mm+) | FST | 19007-05/07/09 | Craniotomy |
Mineral oil | Sigma | Pcode 1002076577; M5904-500mL | Various steps |
Mineral oil | Sigma | Pcode 1002076577; M5904-500mL | For use keeping craniotomy holes open |
Miniature flathead screwdriver | FST | 30051-10 | Insertion/tightening of bone screws |
Neosporin Triple Antibiotic Ointment | Johnson & Johnson | 512373700 | Antibiotic ointment |
Omnetics 44 socket nano connector | Neuralynx | Neuralynx part #A70427-801 | NONSTANDARD ITEM- omnetics 44 socket (female) dual row straight leg nano connector with 2 guide pins (male) for use with custom-made counterbalance apparatus |
Platinum 10% iridium wire | California fine wire | MO# M374710 | Fine recording wire spun into tetrodes for use during recording by use of the terode assembly station and spinner 2.0 (see below); HML NATRL VG BOND COAT; SIZE .0007 X 200FT |
Platinum black plating solution | Neuralynx | Platinum black plating solution | Plating |
Polycarbonate cage bottom | Thomas Scientific/Maryland plastics | 1113M35; mfr. No. E0270 | Standard cage bottom; can be fitted with wire mesh apparatus over top that contains chow+water bottle for unimplanted mice |
Polycarbonate cage top with N10 micro filter | Ancare | N/A | Standard cage top to be modified with PVC pipe for counterbalance apparatus |
Povidone iodine 10% | Generic | Commercially available | For standard pre-operative sterilization procedure |
PVC pipe | Charlotte pipe | N/A | 1/2" x 600 PSI schedule 40 white PVC pipe; for use/assembly into counterbalance apparatus during mouse recovery |
Scalpel blades- #4 | FST | 10060-00 | Incision use |
Scalpel handle- #4 gross anatomy | FST | 10060-13 | Incision use |
Self-holding pin and bone screw forceps | FST | 26100-00 | Holder for bone and ground screws while inserting into skull |
Small EIB pins | Neuralynx | Small EIB pins | Attachment of tetrode wires to EIB board |
Small polyimide tubing | Nordson medical | Lot # 19102423 | Polyimide tubing- inner diameter 0.004''; outer diameter 0.0044''; length 36" |
SolidWorks | Dassault Systemes | SolidWorks | 3D CAD program for micro-drive design |
Spatula and probe | FST | 1090-13 | Applicator for petroleum jelly/mineral oil + optional use for ad hoc tetrode straightening |
Spring scissors- 8 mm | FST | 15024-10 | Scissors for cranial tissue incisions |
Spring scissors- 8 mm | FST | 15024-10 | Initial incisions |
Standard pattern forceps | FST | 11000-12 | Large serrated forceps |
Surgical scissors- sharp-blunt | FST | 14001-12 | Various |
Surgical scissors- ToughCut | FST | 14054-13 | Various |
Tetrode assembly station | Neuralynx | Tetrode assembly station | Tetrode Assembly |
Tetrode spinner 2.0 | Neuralynx | Tetrode spinner 2.0 | Tetrode Assembly |
Two-part epoxy | Gorilla brand | 4200102 | Various steps |
This article has been published
Video Coming Soon
ABOUT JoVE
Copyright © 2024 MyJoVE Corporation. All rights reserved