A subscription to JoVE is required to view this content. Sign in or start your free trial.
The protocol describes the methodology of extracellular recording in the motor cortex (MC) to reveal extracellular electrophysiological properties in freely moving conscious mice, as well as the data analysis of local field potentials (LFPs) and spikes, which is useful for evaluating the network neural activity underlying behaviors of interest.
The protocol aims to uncover the properties of neuronal firing and network local field potentials (LFPs) in behaving mice carrying out specific tasks by correlating the electrophysiological signals with spontaneous and/or specific behavior. This technique represents a valuable tool in studying the neuronal network activity underlying these behaviors. The article provides a detailed and complete procedure for electrode implantation and consequent extracellular recording in free-moving conscious mice. The study includes a detailed method for implanting the microelectrode arrays, capturing the LFP and neuronal spiking signals in the motor cortex (MC) using a multichannel system, and the subsequent offline data analysis. The advantage of multichannel recording in conscious animals is that a greater number of spiking neurons and neuronal subtypes can be obtained and compared, which allows the evaluation of the relationship between a specific behavior and the associated electrophysiological signals. Notably, the multichannel extracellular recording technique and the data analysis procedure described in the present study can be applied to other brain areas when conducting experiments in behaving mice.
The local field potential (LFP), an important component of extracellular signals, reflects the synaptic activity of large populations of neurons, which form the neural code for multiple behaviors1. Spikes generated by neuronal activity are considered to contribute to the LFP and are important for neural coding2. Alterations in spikes and LFPs have been proven to mediate several brain diseases, such as Alzheimer's disease, as well as emotions such as fear, etc.3,4. It is worth noting that many studies have highlighted that spike activity significantly differs ....
All the mice were obtained commercially and maintained in a 12 h light/12 h dark cycle (light on at 08:00 A.M. local time) at a room temperature of 22-25 °C and a relative humidity of 50%-60%. The mice had access to a continuous supply of food and water. All the experiments were carried out in accordance with the Guidelines for Care and Use of Laboratory Animals of South China Normal University and approved by the Institutional Animal Ethics Committee. Male C57BL/6J mice aged 3-5 months old were used for the experim.......
A high-pass (250 Hz) filter was applied to extract the multi-unit spikes from the raw signals (Figure 6A). Further, the recorded units from the MC of a normal mouse sorted by PCA were verified (Figure 7A-D), and the valley width and waveform duration of the units in the MC of the mouse were recorded. The results showed that both the valley width and waveform duration of the MC putative pyramidal neurons (Pyn) in mice are higher .......
Multichannel recording in free-moving mice has been deemed to be a useful technology in neuroscience studies, but it is still quite challenging for beginners to record and analyze the signals. In the present study, we provide simplified guidelines for making micro-drive systems and performing electrode implantation, as well as simplified procedures for capturing and analyzing the electrical signals via spike sorting software and software for neurophysiological data analysis.
Given tha.......
This work was supported by grants from the National Natural Science Foundation of China (31871170, 32170950, and 31970915), the Natural Science Foundation of Guangdong Province (2021A1515010804 and 2023A1515010899), the Guangdong Natural Science Foundation for Major Cultivation Project (2018B030336001), and the Guangdong Grant: Key Technologies for Treatment of Brain Disorders(2018B030332001).
....Name | Company | Catalog Number | Comments |
2.54 mm pin header | YOUXIN Electronic Co., Ltd. | 1 x 5 | Applying for the movable micro-drive which can slide on its stulls. |
Adobe Illustrator CC 2017 | Adobe | N/A | To optimize images from GraphPad. |
BlackRock Microsystems | Blackrock Neurotech | Cerebus | This systems includes headsatge, DA convert, amplifier and computer. |
Brass nut | Dongguan Gaosi Technology Co., Ltd. | M0.8 brass nut | The nut fixes the position of screw. |
Brass screw | Dongguan Gaosi Technology Co., Ltd. | M0.8 x 11 mm brass screw | A screw that hold the movable micro-drive. |
C57BL/6J | Guangdong Zhiyuan Biomedical Technology Co., LTD. | N/A | 12 weeks of age. |
Centrifuge tube | Biosharp | 15 mL; BS-150-M | To store mice brain with sucrose sulutions. |
Conducting paint | Structure Probe, Inc. | 7440-22-4 | To improve the lead-connecting quality between connector pins and Ni-wires. |
Conductive copper foil tape | 3M | 1181 | To reduce interferenc. |
Connector | YOUXIN Electronic Co., Ltd. | 2 x 10P | To connect the headtage to micro-drive system. |
DC Power supply | Maisheng | MS-305D | A power device for electrolytic lesion. |
Dental cement | Shanghai New Century Dental Materials Co., Ltd. | N/A | To fix the electrode arrays on mouse's skull after finishing the implantation. |
Digital analog converter | Blackrock | 128-Channel | A device that converts digital data into analog signals. |
Epoxy resin | Alteco | N/A | To cover pins. |
Excel | Microsoft | N/A | To summarize data after analysis. |
Eye scissors | JiangXi YuYuan Medical Equipment Co.,Ltd. | N/A | For surgery or cutting the Ni-chrome wire. |
Fine forceps | JiangXi YuYuan Medical Equipment Co.,Ltd. | N/A | For surgery. |
Forceps | JiangXi YuYuan Medical Equipment Co.,Ltd. | N/A | For surgery or assembling the mirco-drive system. |
Freezing microtome | Leica | CM3050 S |  Cut the mouse’s brain into slices |
Fused silica capillary tubing | Zhengzhou INNOSEP Scientific Co., Ltd. | TSP050125 | To serve as the guide tubes for Ni-chrome wires. |
Glass microelectrode | Sutter Instrument Company | BF100-50-10 | To mark the desired locations for implantation using the filled ink. |
GraphPad Prism 7 | GraphPad Software | N/A | To analyze and visualize the results. |
Guide-tube | Polymicro technologies | 1068150020 | To load Ni-chrome wires. |
Headstage | Blackrock | N/A | A tool of transmitting signals. |
Helium balloon | Yili Festive products Co., Ltd. | 24 inch | To offset the weight of headstage and micro-drive system. |
Ink | Sailor Pen Co.,LTD. | 13-2001 | To mark the desired locations for implantation. |
Iodine tincture | Guangdong Hengjian Pharmaceutical Co., Ltd. | N/A | To disinfect mouse's scalp. |
Lincomycin in Hydrochloride and Lidocaine hydrochloride gel | Hubei kangzheng pharmaceutical co., ltd. | 10g | A drug used to reduce inflammation. |
Meloxicam | Vicki Biotechnology Co., Ltd. | 71125-38-7 | To reduce postoperative pain in mice. |
Micromanipulators | Scientifica | Scientifica IVM Triple | For electrode arrays implantation. |
Microscope | Nikon | ECLIPSE Ni-E |  Capture the images of brain sections |
nanoZ impedance tester | Plexon | nanoZ | To measure impedance or performing electrode impedance spectroscopy (EIS) for multichannel microelectrode arrays. |
NeuroExplorer | Plexon | NeuroExplorer | A tool for analyzing the electrophysiological data. |
NeuroExplorer | Plexon, USA | N/A | A software. |
Ni-chrome wire | California Fine Wire Co. | M472490 | 35 μm Ni-chrome wire. |
Offline Sorter | Plexon | Offline Sorter | A tool for sorting the recorded multi-units. |
PCB board | Hangzhou Jiepei Information Technology Co., Ltd. | N/A | Computer designed board. |
Pentobarbital | Sigma | P3761 | To anesthetize mice. |
Pentobarbital sodium | Sigma | 57-33-0 | To anesthetize the mouse. |
Peristaltic pump | Longer | BT100-1F | A device used for perfusion |
Polyformaldehyde | Sangon Biotech | A500684-0500 | The main component of fixative solution for fixation of mouse brains |
PtCl4 | Tianjin Jinbolan Fine Chemical Co., Ltd. | 13454-96-1 | Preparation for gold plating liquid. |
Saline | Guangdong Hengjian Pharmaceutical Co., Ltd. | N/A | To clean the mouse's skull. |
Silver wire | Suzhou Xinye Electronics Co., Ltd. | 2 mm diameter | Applying for ground and reference electrodes. |
Skull drill | RWD Life Science | 78001 | To drill carefully two small holes on mouse's skull. |
Stainless steel screws | YOUXIN Electronic Co., Ltd. | M0.8 x 2 | To protect the micro-drive system and link the ground and reference electrodes. |
Stereotaxic apparatus | RWD Life Science | 68513 | To perform the stereotaxic coordinates of bilateral motor cortex. |
Sucrose | Damao | 57-50-1 | To dehydrate the mouse brains after perfusion. |
Super glue | Henkel AG & Co. | PSK5C | To fix the guide tube and Ni-chrome wire. |
Temperature controller | Harvard Apparatus | TCAT-2 | To maintain mouse's rectal temperature at 37°C |
Tetracycline eye ointment | Guangdong Hengjian Pharmaceutical Co., Ltd. | N/A | To protect the mouse's eyes during surgery. |
Thread | Rapala | N/A | To link ballon and headstage. |
Vaseline | Unilever plc | N/A | To cover the gap between electrode arrays and mouse's skull. |
This article has been published
Video Coming Soon
ABOUT JoVE
Copyright © 2024 MyJoVE Corporation. All rights reserved