Mechanisms of sudden unexpected death in epilepsy (SUDEP) are poorly understood and challenging to translate from current models. Transgenic rabbits may offer insights into these mechanisms. We describe a method for long-term, continuous electroencephalography and electrocardiography recordings in transgenic rabbit kits to evaluate serious events that may lead to death.
Pathogenic variants in ion channel genes are associated with a high rate of sudden unexpected death in epilepsy (SUDEP). Mechanisms of SUDEP are poorly understood but may involve autonomic dysfunction and cardiac arrhythmias in addition to seizures. Some ion-channel genes are expressed in both the brain and the heart, potentially increasing the risk of SUDEP in patients with ion-channelopathies associated with epilepsy and cardiac arrhythmias. Transgenic rabbits expressing epilepsy variants provide a whole organism to study the complex physiology of SUDEP. Importantly, rabbits more closely replicate human cardiac physiology than do mouse models. However, rabbit models have additional health and anesthesia considerations when undergoing invasive monitoring procedures. We have developed a novel method to surgically implant a telemetry device for long-term simultaneous electroencephalogram (EEG) and electrocardiogram (ECG) monitoring in neonatal rabbit kits. Here, we demonstrate surgical methods to implant a telemetry device in P14 (weight range 175-250 g) kits with detailed attention to surgical approach, appropriate anesthesia and monitoring, and postoperative care, resulting in a low complication rate. This method allows for continuous monitoring of neural and cardiac electrophysiology during critical points in the development of cardiac arrhythmias, seizures, and potential SUDEP in rabbit models of genetic or acquired epilepsies.
Sudden unexpected death in epilepsy (SUDEP) is a leading cause of death in patients with epilepsy. Mechanisms of SUDEP are poorly understood but potentially involve autonomic dysfunction, apnea, and cardiac arrhythmias in addition to seizures1,2,3,4,5,6,7. Patients with channelopathy-linked genetic epilepsies have among the highest rates of SUDEP. For example, SUDEP occurs in up to 20% of patients with variants in the voltage-gated sodium....
All work described was reviewed and approved by the University of Michigan Institutional Animal Care and Use Committee as part of an approved animal use protocol and is in line with relevant federal laws and guidelines, including the USDA Animal Welfare Act and NIH Public Health Service Policy. The University of Michigan is an AAALACi-accredited institution.
1. Animal preparation
The successful outcome of this project required the development of multiple parameters in the implant procedure and recording protocol. Implant surgery was attempted or performed on 16 rabbit kits, with 14 successfully surviving the procedure. Of those, 12 survived to the experimental endpoint. Reasons for intraoperative or postoperative death are highlighted in Table 1, along with procedure modifications that allowed for future success in achieving the experimental endpoint. The most common operative co.......
The protocol described for anesthetic induction, monitoring, and support balances research needs for surgical approach and ease with gold standards of veterinary care. Prior to the laboratory adopting the described protocol as standard procedure, several other potential refinements were trialed, including dorsal subcutaneous implant placement, the use of an endotracheal tube or laryngeal mask airway, and the use of an esophageal stethoscope attachment for heart rate monitoring. However, all were ultimately abandoned for .......
The authors have nothing to disclose.
The authors are grateful for funding by NIH R61NS130070 to LLI.
....Name | Company | Catalog Number | Comments |
1 inch elastic wrap - Coban or Vetwrap | 3M | https://www.3m.com/3M/en_US/p/d/b00003186/ | |
4-0 PDS monofilament suture | Ethicon | https://www.jnjmedtech.com/en-US/company/ethicon/all-products | |
5-0 Ethilon nylon suture | Ethicon | https://www.jnjmedtech.com/en-US/company/ethicon/all-products | |
Acquisition computer | Dell | https://www.dell.com/en-us | |
Adhesive surgical towels | N/A | N/A | |
Anesthesia circuit - Jackson-Reevs with 0.5 L rebreathing bag | JorVet | J0248GA | |
Betadine scrub | N/A | N/A | |
Bupivicaine (0.5%) | N/A | N/A | Diluted to 2.5 mg/mL prior to administration |
Buprenorphine (0.3 mg/mL) | N/A | N/A | Diluted to 0.03 mg/mL prior to administration |
Burr - 1.00 mm | Cell Point Scientific | 60-1000 | to drill skull |
Cafazolin (1 g lypholized) | N/A | N/A | Diluted to 50 mg/mL |
Carprofen (50 mg/mL) | MWI Veterinary | Diluted to 25 mg/mL prior to administration | |
Cotton tipped applicators | N/A | N/A | |
Custom 3-D printed face mask | N/A | https://www.thingiverse.com/thing:923725 | |
Dental acrylic | N/A | N/A | |
Diet Gel Criticare | Clear H2O | 72-05-5042 | Nutritional support |
Dopper Gel - Aquasonic | Patterson | 07-890-5542 | |
Doppler - Vet-Dop2 | Patterson | 07-888-8986 | |
Doxapram (20 mg/mL) | MWI Veterinary | N/A | Emergency only |
Dumont #5 Fine Forceps | Fine Science Tools | 11254-20 | For holding screws |
Duraprep | 3M | 8630 | Final skin prep |
ecgAuto data analysis software | emka technologies | N/A | |
Epinephrine (1:1000) | MWI Veterinary | N/A | Emergency only |
Gauze | N/A | N/A | |
Glucometer ipet Pro | MWI Veterinary | 63867 | Monitor if poor recovery |
Glycopyrrolate (0.2 mg/mL) | MWI Veterinary | N/A | Emergency only |
Gram scale | N/A | N/A | |
Hemostats | Fine Science Tools | 13008-12 | Hold wire loops while tying the loop in place |
Ideal Micro-drill | Cell Point Scientific | 67-1204 | To drill skull |
Incubator | DRE-veterinary (Infantia - NB1) | N/A | |
Induction box | VetEquip | 941444 | |
Infared heating pad - RightTemp Jr | Kent Scientific Corporation | RT-0502 | |
IOX2 data acquisition software | emka technologies | N/A | |
IV Catheter - Covidein Monoject 26 G, 3/4 inch PTFE | Patterson | 07-836-8494 | |
ketamine (100 mg/mL) | MWI Veterinary | N/A | |
Medical tape | N/A | N/A | |
Narrow Pattern Forceps - Straight/12 cm | Fine Science Tools | 11002-12 | |
Neonatal stethescope | Ultrascope | N/A | |
Olsen-Hegar Needle holder with scissors - 12 cm | Fine Science Tools | 12002-12 | For suturing |
Ophthalmic ointment Puralube | MWI Veterinary | N/A | Administered to both eyes during anesthesia |
Opthalmic Lubricant - Paralube Vet | Patterson | 07-888-2572 | |
Pulse oximeter (AccuWave Portable ) | Patterson | 07-892-9128 | For prep and recovery; reads HR up to 400 |
Pulse oximeter (SDI - Vet/Ox plus 4700) | Heska | N/A | Intra-operative; no longer producted |
Receiver | emka technologies | N/A | 1 receiver for every 4 telemetry implants |
Rectal thermometer | N/A | N/A | |
Scalpel | Fine Science Tools | 10003-12 | |
Scissors | Fine Science Tools | 14002-12 | To cut drape |
Screw driver - 1.0 mm | N/A | N/A | From mini-screwdriver set for electronics |
Screws 00-96 x 3/32 (2.4 mm) | Protech International | 8L0X3905202F | |
Sevoflurane | MWI Veterinary | Maintenance anesthesia | |
Sevoflurane vaporizer and anesthesia machine | N/A | N/A | |
Skin glue, Gluture | MWI Veterinary | 34207 | Apply sparingly with syringe |
Small scissors | Fine Science Tools | 14084-08 | |
Sterile aluminum foil | N/A | N/A | To wrap wires prior to rotating animal |
Sterile paint brush | N/A | N/A | To apply dental acrylic |
Sterile Saline | N/A | N/A | |
Sterile surgical gloves | N/A | N/A | |
Sterile ultrasound cover | N/A | N/A | To cover the drill |
Sterile Water | N/A | N/A | For cefazolin reconstitution |
Surgical blade no. 15 | N/A | N/A | |
Surgical drape | N/A | N/A | |
Surgical gown | N/A | N/A | |
Swivel connector - Jorgensen Labs | Patterson | 07-802-2349 | To connect anesthesia circuit to face mask |
Telemetry implant | emka technologies | easyTEL+_M1_EETA_B_35 | |
Trocar | SAI | TRO-10-6 | To tunnel wires |