JoVE Logo
Faculty Resource Center

Sign In

Abstract

Genetics

2D-HELS MS Seq: A General LC-MS-Based Method for Direct and de novo Sequencing of RNA Mixtures with Different Nucleotide Modifications

Published: July 10th, 2020

DOI:

10.3791/61281

1Department of Biological and Chemical Sciences, New York Institute of Technology, 2Department of Chemical Engineering, Columbia University, 3Department of Chemistry, Hunter College, City University of New York, 4Department of Computer Science, New York Institute of Technology

Mass spectrometry (MS)-based sequencing approaches have been shown to be useful in direct sequencing RNA without the need for a complementary DNA (cDNA) intermediate. However, such approaches are rarely applied as a de novo RNA sequencing method, but used mainly as a tool that can assist in quality assurance for confirming known sequences of purified single-stranded RNA samples. Recently, we developed a direct RNA sequencing method by integrating a 2-dimensional mass-retention time hydrophobic end-labeling strategy into MS-based sequencing (2D-HELS MS Seq). This method is capable of accurately sequencing single RNA sequences as well as mixtures containing up to 12 distinct RNA sequences. In addition to the four canonical ribonucleotides (A, C, G, and U), the method has the capacity to sequence RNA oligonucleotides containing modified nucleotides. This is possible because the modified nucleobase either has an intrinsically unique mass that can help in its identification and its location in the RNA sequence, or can be converted into a product with a unique mass. In this study, we have used RNA, incorporating two representative modified nucleotides (pseudouridine (Ψ) and 5-methylcytosine (m5C)), to illustrate the application of the method for the de novo sequencing of a single RNA oligonucleotide as well as a mixture of RNA oligonucleotides, each with a different sequence and/or modified nucleotides. The procedures and protocols described here to sequence these model RNAs will be applicable to other short RNA samples (<35 nt) when using a standard high-resolution LC-MS system, and can also be used for sequence verification of modified therapeutic RNA oligonucleotides. In the future, with the development of more robust algorithms and with better instruments, this method could allow sequencing of more complex biological samples. 

Tags

Direct Sequencing

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved