A subscription to JoVE is required to view this content. Sign in or start your free trial.
We describe a minimally invasive surgery using a full-endoscopy system for the single segmental thoracic ossification of the ligamentum flavum, combined with dural ossification, at Hebei General Hospital.
Ossification of the ligamentum flavum (OLF) can result in spinal stenosis. Thoracic spinal cord compression due to spinal stenosis is a common cause of progressive thoracic myelopathy in Asian countries. The incidence of complications is high in open decompression surgeries for thoracic OLF. With dural ossification (DO), the risk of complications is even higher in thoracic OLF. We introduce a full-endoscopic decompression surgery for thoracic OLF combined with DO under local anesthesia. Hemilaminectomy is performed using a high-speed burr under the endoscopy first, and then decompression of the contralateral spinal canal is completed using an "over the top" technique. DO resection uses the eggshell technique; after the base of the DO is cut from the lamina, forceps or lamina rongeurs are typically used for removal. The dural defect left after resection does not need repair. Neurological function was improved, and no complications such as hematoma or neck pain occurred. On imaging, no pseudodural cyst, cerebrospinal fluid leakage, or wound complications were observed after the operation. Endoscopic surgery causes less damage to the posterior ligament complex, so no cases of persistent back pain complaints or secondary internal fixation requirements were found in this study. Full-endoscopic decompression can achieve good imaging and clinical effects in the treatment of thoracic OLF with DO.
Ossification of the ligamentum flavum (OLF) is one of the most common causes of thoracic myelopathy or radiculopathy in Asian countries, especially in Japan1,2. The prevalence has been reported to vary from 3.8% to 26% in East Asia1,3,4. Posterior decompression is recommended for the treatment of thoracic OLF according to the compression location and its aetiologies5. Dural ossification (DO) is a difficult problem in surgical procedures6; when the dura mater is ossified,....
This study was approved by the Ethics Committee of Hebei General Hospital. Informed consent was obtained from all individual participants.
1. Preoperative preparation
From June 2017 to December 2020, full-endoscopic decompression surgeries were performed on four patients in our hospital, including one male and three females aged 46-72 years with an average age of 64.3 years. The average operation time was 185.3 min. The mean follow-up was 16 months. Patients experienced relief of their myelopathy symptoms. The modified Japanese Orthopedic Association (mJOA) score improved at the last follow-up. The Patient Satisfaction Index (PSI)14 at the last follow-up was 75.......
Although endoscopic thoracic surgery has achieved satisfactory clinical outcomes10,15,16, there are still debates on some operation details, such as the operation sequence, surgical instruments, and decompression skills. The operation sequence and the resection of the DO are the key steps of the surgery. Some surgeons prefer to perform contralateral decompression first and then remove the ipsilateral ossification
None.
....Name | Company | Catalog Number | Comments |
Picture Archiving and Communication System (PACS) | Neusoft Co., Ltd. | Neusoft PACS | Image requirement: DICOM; Running system: Windows 7 or Windows 10 |
Endoscope system | SPINENDOS GmbH | SP081430.030 | Inner diameter:4.3mm; Outer diameter:7.0mm; Field angle: 80 °; Visual angle: 30 °; Working length: 181 mm. |
Working sheath | SPINENDOS GmbH | SP082615.265 | Φ7.2mm×178mm |
Puncture needle | SPINENDOS GmbH | SP082016.150 | 1.6mm×150mm |
Guide rod | SPINENDOS GmbH | SP082616.300 | Φ7.0mm×225mm |
Endoscopic rongeur | SPINENDOS GmbH | SP082700.040L | Φ4.0mm×360mm |
Bipolar electrocoagulation probe | ELLIQUENCE | DTF-40 | 40cm |
Endoscopic forceps | SPINENDOS GmbH | SP082781.835 | Φ2.5mm×330mm |
Endoscopic hook | SPINENDOS GmbH | SP082628.351 | Φ2.5mm×310mm |
High-speed burr | XIYI | MQZ | Φ3.2mm×328mm |