The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.

In 1967, Kamentsky and Melamed achieved the diversion of cells away from the flow, allowing cell sorting. But it was not until 1973 that a refined electrostatic sorter, known as a fluorescence assisted cell sorter or FACS, was developed. Typically, the cell suspension passes through a laser beam, and the light scatter, or fluorescence, is detected. The changes in scatter patterns or fluorescence determine how the cells should be sorted.

Applications of Flow Cytometry

Apart from cell counting and sorting, flow cytometry is also used to estimate the DNA and RNA content of cells. When a cell suspension is incubated with fluorochromes, viable cells take up the stains to different degrees based on cell type and growth phase. These differences are detected by the FACS software, which then estimates the relative proportions of the cell types in different growth phases. Since flow cytometry estimates cell parameters such as shape, size, and granularity, it can also be used to differentiate necrotic and apoptotic cells. For example, apoptotic cells are typically more granular and therefore tend to have a higher side scatter of light than the less granular necrotic cells.

Limitations of Flow Cytometry

An obvious limitation of flow cytometry is that it cannot analyze cells that are not suspended in culture, such as those growing on an adherent medium or organized in a tissue. All samples must be dissociated into cell suspensions to generate single-cell droplets; therefore, cell-cell interactions cannot be analyzed. Another constraint stems from the limit on the number of simultaneous detectors. Despite many fluorophores being available, a flow cytometer usually does not have more than 12 detectors to efficiently and consistently detect the different cell subpopulations. While flow cytometry is a powerful technique, it can also generate an overwhelming quantity of data that requires a human expert to analyze and process. And finally, given the high sensitivity of this technique, standard protocols for sample preparation, data recording, and analysis are essentia. However, a lack of standardization of these aspects makes it difficult to compare results from different studies.

Tags
Flow CytometryCell SortingAndrew MoldavanMultiparameter Flow CytometerFluorescence Assisted Cell Sorter FACSCell CountingDNA Content EstimationRNA Content EstimationFluorochromesApoptotic CellsNecrotic CellsData Analysis Limitations

来自章节 32:

article

Now Playing

32.7 : Flow Cytometry

Analyzing Cells and Proteins

11.4K Views

article

32.1 : 细胞分离和分离概述

Analyzing Cells and Proteins

5.3K Views

article

32.2 : 细胞培养

Analyzing Cells and Proteins

15.8K Views

article

32.3 : 细胞系

Analyzing Cells and Proteins

6.8K Views

article

32.4 : 杂交瘤技术

Analyzing Cells and Proteins

13.2K Views

article

32.5 : 组织匀浆和细胞裂解

Analyzing Cells and Proteins

7.0K Views

article

32.6 : 亚细胞组分分离

Analyzing Cells and Proteins

6.4K Views

article

32.8 : 柱色谱原理

Analyzing Cells and Proteins

6.4K Views

article

32.9 : 柱色谱的类型

Analyzing Cells and Proteins

10.6K Views

article

32.10 : 免疫沉淀

Analyzing Cells and Proteins

5.1K Views

article

32.11 : 标记和融合蛋白

Analyzing Cells and Proteins

6.5K Views

article

32.12 : SDS 页面

Analyzing Cells and Proteins

26.0K Views

article

32.13 : 蛋白质印迹

Analyzing Cells and Proteins

14.0K Views

article

32.14 : 二维凝胶电泳

Analyzing Cells and Proteins

5.5K Views

article

32.15 : 酶联免疫吸附测定

Analyzing Cells and Proteins

11.8K Views

See More

JoVE Logo

政策

使用条款

隐私

科研

教育

关于 JoVE

版权所属 © 2025 MyJoVE 公司版权所有,本公司不涉及任何医疗业务和医疗服务。