JoVE Logo

Anmelden

Zum Anzeigen dieser Inhalte ist ein JoVE-Abonnement erforderlich. Melden Sie sich an oder starten Sie Ihre kostenlose Testversion.

In diesem Artikel

  • Overview
  • Protokoll
  • Offenlegungen
  • Materialien
  • Referenzen

Overview

In this video, we demonstrate the negative staining of enveloped virus samples using a processing capsule within the biocontainment environment. The negatively stained viruses can be visualized using transmission electron microscopy to investigate viral structure and morphology with nanometer resolution.

Protokoll

1. The Capsule Method for Inactivation in Biocontainment with 2% Glutaraldehyde, Followed by Negative Staining in a BSL-2 Laboratory

  1. Virus inactivation procedure. 
    1. Inside the biocontainment BSC, mix the virus suspension well with the same volume of 4% glutaraldehyde to achieve a final concentration of 2% glutaraldehyde.
      Caution: Glutaraldehyde is a hazardous chemical and requires appropriate protection. Glutaraldehyde can be used for brief periods in a normal BSC, but extended open reagent requires working in a ducted BSC or chemical fume hood.
    2. Inactivate viruses with fixative for a minimum of 24 h before packaging, decontamination, and transfer it to the BSL-2 EM facility.
  2. In the BSL-2 EM facility, aspirate the virus and fixative mixture into the capsule, containing two TEM grids, attached to a pipette.
  3. Place the pipette horizontally for 10 min with the grids oriented horizontally.
    NOTE: This is to promote an even distribution of virus particles onto the TEM grids.
  4. Pick up the pipette and depress the plunger to expel the virus to a waste container. Aspirate 40 μL of dI water into the capsules and expel it into the waste container for 3 rinse cycles.
  5. Aspirate 40 μL of either 1% uranyl acetate (UA) or 1% potassium phosphotungstic acid (PTA) into the capsules for 30 s.
    NOTE: Staining time varied from 10 s to 1 min based on virus sample.
    Caution: UA is an alpha emitter, and a cumulative toxin. Handle it with appropriate protection.
  6. Remove the capsule from the pipette and blot dry the grids by touching the edge of the grids to a piece of filter paper. Air dry the grids and store them for subsequent TEM imaging.

Offenlegungen

No conflicts of interest declared.

Materialien

NameCompanyCatalog NumberComments
Formvar/carbon coated TEM grids SPI 3420C-MB 200 mesh Cu Pk/100
mPrep/g capsules EMS 85010-01 Box
mPrep/f couplers EMS 85010-11 Standard 16/Pk
Glutaraldehdyde EMS 1632050% solution, EM grade
Uranyl Acetate EMS 22400Powder
Potassium phosphotungstic acid EMS 19500Powder
Filter paper Whatman 1450-090 Size 50
Tranmission Electron Microscope JEOL JEM-1011 TEM

Referenzen

This article has been published

Video Coming Soon

JoVE Logo

Datenschutz

Nutzungsbedingungen

Richtlinien

Forschung

Lehre

ÜBER JoVE

Copyright © 2025 MyJoVE Corporation. Alle Rechte vorbehalten