A subscription to JoVE is required to view this content. Sign in or start your free trial.
* These authors contributed equally
Here, we describe a protocol to use in vivo four-dimensional ultrasound imaging and ex vivo mass spectrometry imaging to assess biomechanical and biomolecular alterations in the murine cardiovascular system. This technique is applied to analyze cardiac remodeling in surgically induced myocardial infarction and vascular changes in aging animals.
Cardiovascular disease (CVD) is the leading cause of death in the United States. Damage in the cardiovascular system can be due to environmental exposure, trauma, drug toxicity, or numerous other factors. As a result, cardiac tissue and vasculature undergo structural changes and display diminished function. The damage and the resulting remodeling can be detected and quantified with ultrasound (US) imaging at the organ level and mass spectrometry imaging (MSI) at the molecular level. This manuscript describes an innovative methodology for studying murine cardiac pathophysiology, coupling in vivo four-dimensional (4D) ultrasound imaging and analysis with ex vivo matrix-assisted laser desorption/ionization (MADLI) MSI of the heart. 4D ultrasound can provide dynamic volumetric measurements, including radial displacement, surface area strain, and longitudinal strain throughout an entire cardiac cycle. In the vasculature, MSI and ultrasound are used to assess vessel wall compositions, hemodynamics, and vessel wall dynamics. The methodology can be tailored to study a myriad of CV diseases by adjusting functional metrics of interest and/or varying MALDI MSI protocol to target specific molecules. MALDI MSI can be used to study lipids, small metabolites, peptides, and glycans. This protocol outlines the use of MALDI MSI for untargeted lipidomic analysis and the use of ultrasound imaging for cardiovascular hemodynamics and biomechanics.
Cardiovascular disease (CVD) is a leading cause of mortality worldwide1. Prevention and treatment of CVD require an in-depth understanding of molecular adaptations to biomechanical forces and the resulting changes in mechanical properties. Throughout the entire cardiovascular system, biomechanical forces play an important role in the function and structure of the tissue2. The mechanical properties of cardiovascular (CV) tissue are influenced by these forces, making them indicators of health and disease3,4,5....
The described animal experiments are carried out with the University of Tennessee, Knoxville Institutional Animal Care and Use Committee approval.
1. Ultrasound imaging13
The imaging protocols described above were used for two preliminary studies: myocardial infarction (MI) remodeling and vascular aging. For the cardiac experiments, a permanent coronary artery ligation surgery was done in order to induce acute myocardial infarction18,19. 4D ultrasound and MALDI MSI were performed progressively on the same tissue, unveiling physiological and molecular changes. Representative molecular ion images in an infarcted heart are shown in <.......
US imaging can be operator-dependent, but the use of anatomical landmarks and adequate training can limit user bias. 2D ultrasound is particularly susceptible to inter-user variability because views are angle-dependent, whereas 4DUS is less susceptible as acquisition encompasses the entire volume and is angle-independent. It was also determined that image reproducibility is easier to achieve because of the adjustable animal platform and transducer holder. US data collection should ideally be conducted by the same researc.......
Allison Jones is supported by the University of Tennessee, Mechanical, Aerospace & Biomedical Engineering Department Graduate Fellowship. Research reported in this publication (Conner Earl) was supported by the National Heart, Lung, and Blood Institute of the National Institutes of Health F30HL162452. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
....Name | Company | Catalog Number | Comments |
2,5-dihydroxybenzoic acid (DHB) | Supelco, >99.0% (HPLC) | 85707-10MG-F | DHB matrix substance for MALDI-MS; https://www.sigmaaldrich.com/US/en/product/sigma/85707?cm_sp=Insite-_-wimsShippingEmailRecs_wims EmailAPI_wimsGruCrossEntropy-_-wimsEmailAPI10-3 |
9-aminoacridine (9AA) | Supelco, ≥99.5% (HPLC) | 92817-1G | 9-Aminoacridine matrix substance for MALDI-MS; https://www.sigmaaldrich.com/US/en/product/sial/92817?srsltid=AfmBOooiQjQ4pWv_XxITkU 4Lkm0UnHXKekGS_ dFl7V40V9QLWoPpNLoc |
Aquasonic Ultrasound Gel | Parker Laboratories | Parker 01-02 | Ultrasound Gel; https://www.parkerlabs.com/products/aquasonic-100-ultrasound-transmission-gel/ |
Benchtop Dewar Flasks | ThermoScientific | 4150-2000 | Container for liquid nitrogen; https://www.thermofisher.com/order/catalog/product/4150-4000?gclid=Cj0KCQjwpvK4BhDUARIsA DHt9sQVc2f-NxN04Nb5Mv F6TZ7GLHWWDEeqDYmEvtKJSQ YHDeVgZ9qylvYaAs27EALw_wcB &source=google_shopping&ISO_ CODE=us&LANG_CODE=en&ef_id =Cj0KCQjwpvK4BhDUARIsADHt9 sQVc2f-NxN04Nb5MvF6TZ7GLHWWDE eqDYmEvtKJSQYHDeVgZ9qylvYa As27EALw_wcB:G:s&s_kwcid=AL!3652 !3!716188292869!!!g!2366243726129 !!21787513085!171591181194&ev_chn =shop&cid=0se_gaw_30092024_ PBYTXL&source=google_shopping &ISO_CODE=us&LANG_CODE= en&gad_source=1 |
Cryostat | Leica Biosystems | CM Series | https://www.leicabiosystems.com/us/histology-equipment/cryostats/ |
Dessicator | VWR | 89054-052 | https://us.vwr.com/store/product/9104882/desiccator-plastic-ace-glass-incorporated |
Epredia MX35 Premier Disposable Low-profile Microtome Blades | Fisher Scientific | 3052835 | Cryostat blade; https://www.fishersci.com/shop/products/mx35-premier-disposable-low-profile-microtome-blades/3052835 |
Falcon 15 mL Conical Centrifuge Tubes | Fisher Scientific | 14-959-53A | Conical Tubes; https://www.fishersci.com/shop/products/falcon-15ml-conical-centrifuge-tubes-5/1495953A?gclid=Cj0KCQjwpvK4BhDUARIsA DHt9sSBcy5n-lhShligJUOX5KKVGn0bt87 8AB2_muOD2PPTue1phpZgeqwa AqgiEALw_wcB&ef_id=Cj0KCQjw pvK4BhDUARIsADHt9sSBcy5n-lhS hligJUOX5KKVGn0bt878AB2_muO D2PPTue1phpZgeqwaAqgiEALw_ wcB:G:s&ppc_id=PLA_goog_20861 45674_81843405034_1495953A__ 386247001345_165426395473886 37329&ev_chn=shop&s_kwcid=AL!4428!3 !386247001345!!!g!856907751004!& gad_source=1 |
Flex-Tubes Microcentrifuge Tubes | Eppendorf | EP022364120 | Centrifuge tubes; https://www.sigmaaldrich.com/US/en/product/sigma/ep022364120?utm_source=google%2Cgoogle&utm _medium=organicshopping%2Ccpc&utm _campaign=21043330280&utm_ content=&gclid=Cj0KCQjwpv K4BhDUARIsADHt9sTHRD35k CHPtfI2A41axodnMVr6a1eBKk zM4bSUYQAyfEKo3UgTAEQa Ap7wEALw_wcB |
Gas Nitrogen | Airgas | N/A | |
Glass microscope slides | Electron Microscopy Sciences | 71873-02 | https://www.emsdiasum.com/positive-charge-microscope-slides |
Liquid Nitrogen | Airgas | N/A | |
Mass Spectrometer | Waters | Synapt G2-Si | https://www.waters.com/waters/en_US/SYNAPT-G2-Si-Mass-Spectrometry/nav.htm?locale=en_mkcid=1000251Foodety%3C/a%3E&cid=134740653&bcid= 134528734 |
Matrix Sprayer | HTX Technologies | M3+ | https://www.htximaging.com/htx-m3-sprayer |
Methanol (HPLC), >99.9% | Fisher Chemical | A4524 | Methanol; https://www.fishersci.com/shop/products/methanol-hplc-fisher-chemical-9/A4524?crossRef=A4524#?keyword=A4524 |
Preclinical Ultrasound System | FUJIFILM VisualSonics | Vevo 3100 | https://www.visualsonics.com/product/imaging-systems/vevo-3100; Vevo F2 has replaced the Vevo 3100 in production. System includes isoflurane vaporizer and induction box. |
Reynolds Wrap | N/A | N/A | Aluminum foil |
Signagel Electrode Gel | Parker Laboratories | Parker 15-60 | Electrode Conducting Gel; https://www.parkerlabs.com/products/signagel-electrode-gel/ |
Sterile Lubricating Jelly | Medline | MDS032273Z | Lubricating Gel; https://www.medline.com/ce/product/Sterile-Lubricating-Jelly/Lubricating-Jelly/Z05-PF03664?sku=MDPMDS032273H |
Surgical instruments: scissors, forceps/tweezers, sutures | Fine Science Tools | 11252-00, 11050-10, 14016-14, 14084-08, 15000-08 | info@finescience.com |
Surgical Sponges 200 Pack –Gauze Pads Non sterile -First Aid Wound Care Dressing Sponge –Woven Medical Nonstick, Non Adherent Mesh Scrubbing | Medpride | B08RZGQ5GW | Gauze; https://www.amazon.com/Medpride-Surgical-Sponges-200-Pack/dp/B08RZGQ5GW/ref=asc_df_B08RZGQ5GW/?tag=hyprod-20&linkCode=df0&h vadid=693270340506&hvpos= &hvnetw=g&hvrand=960915122 2290977669&hvpone=&hvptwo= &hvqmt=&hvdev=c&hvdvcmdl=& hvlocint=&hvlocphy=9192978&hv targid=pla-1245491514869&psc= 1&mcid=33f4d647c88630c79116 888d565a63b0 |
Tissue-Plus O.C.T. Compound | Fisher Scientific | 23-730-571 | OCT; https://www.fishersci.com/shop/products/tissue-plus-o-c-t-compound-2/23730571 |
Wood Handled Cotton Swabs and Applicators | Fisherbrand | 22-363-160 | Cotton swab; https://www.fishersci.com/shop/products/wood-handled-cotton-swabs-applicators-8/p-7146852 |
This article has been published
Video Coming Soon
ABOUT JoVE
Copyright © 2025 MyJoVE Corporation. All rights reserved