Free jets describe the flow of liquid exiting a reservoir through an opening into the atmosphere without resistance. The velocity (v) of the liquid jet is derived using Bernoulli's principle and expressed as:
Where h is the height of the liquid above the opening. This relationship assumes atmospheric pressure at both the reservoir surface and the jet exit. The fluid column's height governs the fluid's velocity at the nozzle in a reservoir, where the fluid's potential energy converts into kinetic energy during flow.
The phenomenon of vena contracta occurs when the liquid exits through a sharp-edged orifice, causing the jet diameter dj to be smaller than the nozzle diameter do. This occurs because the fluid streamlines cannot follow the abrupt edges, creating a contracted flow region. The contraction coefficient is the ratio of the jet's cross-sectional area at the vena contracta to the nozzle's cross-sectional area, quantifying the degree of jet contraction. This parameter is influenced by the nozzle's geometry, with various designs such as knife-edge, sharp-edge, well-rounded, and re-entrant nozzles producing distinct flow patterns and contraction characteristics. For a well-rounded nozzle, Cc = 1.0, while sharp or knife-edged orifices reduce Cc to approximately 0.61. Re-entrant nozzles exhibit even lower values.
These flow characteristics and contraction effects are critical in engineering applications involving liquid discharge, from reservoirs to industrial nozzles.
From Chapter 16:
Now Playing
Fluid Dynamics
61 Views
Fluid Dynamics
481 Views
Fluid Dynamics
426 Views
Fluid Dynamics
461 Views
Fluid Dynamics
116 Views
Fluid Dynamics
689 Views
Fluid Dynamics
472 Views
Fluid Dynamics
68 Views
Copyright © 2025 MyJoVE Corporation. All rights reserved
We use cookies to enhance your experience on our website.
By continuing to use our website or clicking “Continue”, you are agreeing to accept our cookies.