Un abonnement à JoVE est nécessaire pour voir ce contenu. Connectez-vous ou commencez votre essai gratuit.
This video demonstrates a method to record the activity of colonic afferent nerves in an ex-vivo rat colon, cannulated at both ends and infused with saline to increase intraluminal pressure. As pressure increases, the nerve signal rises, indicating its stimulation.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Preparation of Perfusion Solution and Test Compounds
2. Preparation of the Recording Electrode
3. Tissue Collection
4. Dissection of the Colonic Afferent Nerves
5. Preparation of the Suction Electrode
6. Electrophysiological Recording
7. Testing the Colonic Afferent Sensitivity
Access restricted. Please log in or start a trial to view this content.
Figure 1. Electrophysiological Recording of Rat Colonic Afferent Nerves In Vitro. A. A schematic illustration of the ex vivo "tube" colon preparation of the rat. The colorectum, with the attached PG, is superfused in the recording chamber and is cannulated at both ends. Intraluminal infusion is achieved using a syringe pump and moves in the oral to anal direction. Distension of the colon is effected by closing the three-way tap (d) on the outlet cannula. A fine nerve branch from the PG is cut and recorded using a suction electrode. A branch of the LSN and three branches of the PN joining the PG are also shown. a. The proximal cut end of a fine nerve projecting to the colon. b. The distal cut end of the nerve is sucked into the electrode. c. The cut ends of two fine nerves projecting to the urinary bladder. LSN: lumbar splanchnic nerves, PN: pelvic nerves. B. The representative traces of the colonic afferent nerve signal and intraluminal pressure. C. A plot of the pressure-response curve of this nerve.
Access restricted. Please log in or start a trial to view this content.
Name | Company | Catalog Number | Comments |
Sodium Pentobarbital | Shanghai Westang Bio-Tech | B558 | |
Capsaicin | Sigma | M2028 | |
Electrode puller | MicroData Instrument Inc | PMP107 | |
Neurolog System (Bioamplifier) | Digitimer, Ltd | Neurolog System | |
A/D converter | Cambridge Electronic Design | Micro1401 | |
Data processing software | Cambridge Electronic Design | Spike2 version 6 | |
Silver wire | World Precision Instruments | EP12 | |
Glass tubes | World Precision Instruments | 1B150-4 | |
Electrode holder | World Precision Instruments | MEH3SBW | |
Heating bath | Grant | GR150 | |
Dissecting microscope | Leica | Zoom2000 | |
Dissecting microscope | World Precision Instruments | PZMIII-BS | |
Cigarette lighter | any | NA | |
Surgical tools | World Precision Instruments | NA | |
Insect pins | home-made from 0.1 mm stainless steel wire | NA | |
Three way manipulator | World Precision Instruments | KITF-R | |
Rats | Any | NA | Any strain/sex can be used. |
Access restricted. Please log in or start a trial to view this content.
This article has been published
Video Coming Soon
Source: Meng, Y. et al., In Vitro Characterization of the Electrophysiological Properties of Colonic Afferent Fibers in Rats. J. Vis. Exp. (2017)