JoVE Logo
Faculty Resource Center

Sign In

Becton Dickinson Medical Devices (Shanghai) Co Ltd

2 ARTICLES PUBLISHED IN JoVE

image

Immunology and Infection

Detection of Polyfunctional T Cells in Children Vaccinated with Japanese Encephalitis Vaccine via the Flow Cytometry Technique
Linlin Zhang *1,2, Meng Zhang *1,2,3, Mengjia Liu 1,2, Junhong Ai 1,2, Jiao Tian 1,2, Huizheng Ge 4, Ran Wang 1,2, Zhengde Xie 1,2
1Beijing Key Laboratory of Pediatric Respiratory Infectious Diseases, Key Laboratory of Major Diseases in Children, Ministry of Education, National Clinical Research Center for Respiratory Diseases, Laboratory of Infection and Virology, Beijing Pediatric Research Institute, Beijing Children’s Hospital, Capital Medical University, National Center for Children’s Health, 2Research Unit of Critical Infection in Children, 2019RU016, Chinese Academy of Medical Sciences, 3Department of Pediatric Rehabilitation, Beijing Boai Hospital, School of Rehabilitation Medicine, Capital Medical University, China Rehabilitation Research Center, 4Center of Excellence (Beijing), Becton Dickinson Medical Devices (Shanghai) Co Ltd

The present protocol combines ex vivo stimulation and flow cytometry to analyze polyfunctional T cell (TPF) profiles in peripheral blood mononuclear cells (PBMCs) within Japanese encephalitis virus (JEV)-vaccinated children. The detection method and flow cytometry color scheme of JEV-specific TPFs were tested to provide a reference for similar studies.

image

Immunology and Infection

Standardization of Transfer across Labs between Flow Cytometers for Detection of Lymphocytes in Japanese Encephalitis Vaccinated Children
Huizheng Ge *1, Linlin Zhang *2,3, Mengjia Liu *2,3, Xi Yang 1, Xu Wu 1, Ran Wang 2,3, Zhengde Xie 2,3
1Center of Excellence (Beijing), Becton Dickinson Medical Devices (Shanghai) Co Ltd, 2Beijing Key Laboratory of Pediatric Respiratory Infectious Diseases, Key Laboratory of Major Diseases in Children, Ministry of Education, National Clinical Research Center for Respiratory Diseases, Laboratory of Infection and Virology, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, 3Research Unit of Critical Infection in Children, 2019RU016, Chinese Academy of Medical Sciences

In this study, a method was developed to facilitate the transfer of experimental settings and analysis templates between two flow cytometers in two laboratories for the detection of lymphocytes in Japanese encephalitis-vaccinated children. The standardization method for the flow cytometer experiments will allow research projects to be effectively conducted in multiple centers.

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved