In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to the mass spectrometer and analyzed by their m/z values. Since an ICP source operates at atmospheric pressure and a mass spectrometer requires a vacuum, the plasma is passed through an interfacial region, reducing the pressure from 1 bar to around 10−9 bar. The interfacial region consists of two metallic cones (a sampler cone and a skimmer cone), an extraction lens, and a collision cell. The sampler cone and skimmer cone have narrow orifices allowing only a small amount of plasma to pass through. The high negative voltage of the extraction lens allows only the positive ions to enter the collision cell. The collision cell reduces the range of kinetic energies of the ions and directs the ion beam into the quadrupole mass analyzer. ICP–MS is a useful technique in elemental analysis due to its low detection limits, high selectivity, and excellent sensitivity.

タグ

Inductively Coupled PlasmaMass SpectrometryICP MSAtomizerIonizerAnalytesPositive IonsMass SpectrometerInterfacial RegionSampler ConeSkimmer ConeExtraction LensCollision CellQuadrupole Mass AnalyzerElemental AnalysisDetection LimitsSelectivitySensitivity

章から 6:

article

Now Playing

6.13 : Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

Principles of Mass Spectrometry

536 閲覧数

article

6.1 : Mass Spectrometry: Overview

Principles of Mass Spectrometry

3.4K 閲覧数

article

6.2 : Mass Spectrometry: Isotope Effect

Principles of Mass Spectrometry

1.7K 閲覧数

article

6.3 : Mass Spectrometry: Molecular Fragmentation Overview

Principles of Mass Spectrometry

2.7K 閲覧数

article

6.4 : Mass Spectrometers

Principles of Mass Spectrometry

4.6K 閲覧数

article

6.5 : Mass Spectrum

Principles of Mass Spectrometry

1.5K 閲覧数

article

6.6 : Mass Spectrum: Interpretation

Principles of Mass Spectrometry

1.0K 閲覧数

article

6.7 : Mass Analyzers: Overview

Principles of Mass Spectrometry

515 閲覧数

article

6.8 : Mass Analyzers: Common Types

Principles of Mass Spectrometry

510 閲覧数

article

6.9 : High-Resolution Mass Spectrometry (HRMS)

Principles of Mass Spectrometry

1.1K 閲覧数

article

6.10 : Mass Spectrometry: Complex Analysis

Principles of Mass Spectrometry

637 閲覧数

article

6.11 : Tandem Mass Spectrometry

Principles of Mass Spectrometry

730 閲覧数

article

6.12 : Gas Chromatography–Mass Spectrometry (GC–MS)

Principles of Mass Spectrometry

3.6K 閲覧数

article

6.14 : Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Principles of Mass Spectrometry

302 閲覧数

JoVE Logo

個人情報保護方針

利用規約

一般データ保護規則

研究

教育

JoVEについて

Copyright © 2023 MyJoVE Corporation. All rights reserved