The provided content explores the behavior of traveling waves on single-phase lossless transmission lines. It begins with a single-phase two-wire lossless transmission line of length Δx, characterized by a loop inductance LH/m and a line-to-line capacitance C F/m. These parameters result in a series inductance LΔx and a shunt capacitance CΔx.

Figure1

The voltage v(x,t) and current i(x,t) at any position x and time t on the line are expressed using Kirchhoff's Voltage Law (KVL) and Kirchhoff's Current Law (KCL).

Equation1

As Δx approaches zero, partial differential equations emerge, capturing the relationships between voltage, current, and their rates of change with respect to both time and position. Laplace transforms are applied to convert these partial differential equations into ordinary differential equations, assuming zero initial conditions.

Equation2

The solutions to these equations reveal that the velocity of the traveling waves depends on the inductance and capacitance per unit length of the transmission line.

Equation3

These solutions describe forward and backward waves; forward waves travel in the positive x-direction, and backward waves move in the negative x-direction. The solution incorporates a time shift and results in functions that describe voltage and current as sums of forward and backward traveling waves. These waves move in opposite directions along the transmission line, influenced by the line's inductance and capacitance. These expressions lead to the line's characteristic impedance, a function of the inductance and capacitance per unit length.

Equation4

This parameter is crucial for understanding how the waves propagate along the line and interact with the terminations at each end.

章から 32:

article

Now Playing

32.1 : Traveling Waves: Lossless Lines

Transmission Lines: Transient Operation

80 閲覧数

article

32.2 : 境界条件:ロスレスライン

Transmission Lines: Transient Operation

43 閲覧数

article

32.3 : ビューリー格子図

Transmission Lines: Transient Operation

234 閲覧数

article

32.4 : 損失の多いラインと過電圧

Transmission Lines: Transient Operation

46 閲覧数

article

32.5 : 絶縁調整

Transmission Lines: Transient Operation

62 閲覧数

JoVE Logo

個人情報保護方針

利用規約

一般データ保護規則

研究

教育

JoVEについて

Copyright © 2023 MyJoVE Corporation. All rights reserved