In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow path, creating additional resistance and inducing turbulence. The resulting energy dissipation depends on the valve's geometry, position, and flow path design. To quantify this effect, engineers use a loss coefficient, K, which scales with the square of the fluid velocity V as follows:
where:
For ease of calculation, engineers often represent minor losses from fittings and valves as an equivalent length of straight pipe that would produce the same head loss.
At the entry point of a pipe, sharp edges or abrupt changes in flow area can cause the fluid to separate from the wall, creating turbulence and energy dissipation through viscous effects. This entrance loss contributes to the overall energy loss, depending on the pipe geometry and the flow velocity. When fluid exits a pipe, the kinetic energy disperses into the surrounding environment, creating an exit loss characterized by a unity loss coefficient, as all the kinetic energy is lost from the system.
Sudden expansions in the pipe create high-velocity jets that decelerate as they expand, dissipating energy through viscous effects. These expansions lead to additional energy losses as the fluid experiences abrupt pressure and velocity changes. Bends in the pipe also contribute to head loss, primarily due to flow separation and swirling motions induced by centripetal forces as the fluid changes direction. The frictional resistance over the length of the bend adds further to the overall head loss, with the degree of loss depending on the bend angle and radius.
Understanding these minor losses allows engineers to design pipe systems that manage energy dissipation effectively, optimizing flow efficiency and minimizing pressure drops across the system.
章から 21:
Now Playing
Flow in Pipes
66 閲覧数
Flow in Pipes
73 閲覧数
Flow in Pipes
96 閲覧数
Flow in Pipes
58 閲覧数
Flow in Pipes
33 閲覧数
Flow in Pipes
43 閲覧数
Flow in Pipes
21 閲覧数
Flow in Pipes
69 閲覧数
Flow in Pipes
42 閲覧数
Flow in Pipes
42 閲覧数
Flow in Pipes
42 閲覧数
Flow in Pipes
45 閲覧数
Flow in Pipes
49 閲覧数
Copyright © 2023 MyJoVE Corporation. All rights reserved