Overview

In this video, we show a procedure to surgically harvest a functional cardiopulmonary block from a rabbit model. The harvested block can be used for further physiological, pharmacological or biochemical studies.

Protokół

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Equipment and preparation of apparatus.

  1. Equipment arrangement:
    1. Set up an operating table with size according to the weight of the rabbit.
    2. Mount the cover of the artificial thorax on the steel column with the glass chamber underneath and the ventilator with a roller pump by the sides.
    3. Ensure that the cover is easily inclined to have the tracheal cannula in line with the trachea to allow a faster connection.

Access restricted. Please log in or start a trial to view this content.

Ujawnienia

No conflicts of interest declared.

Materiały

NameCompanyCatalog NumberComments
2-Stop Tygon E-Lab Tubing, 3.17 mm ID, 12/pack, Black/WhiteHugo Sachs Elektronik (HSE)73-1864
Adapter for Positive Pressure Ventilation on IPL-4Hugo Sachs Elektronik (HSE)73-4312
Alternative Pressure-Free Gas Supply for IPL-4: To supply the trachea with gas mixture different from room air during negative ventilationHugo Sachs Elektronik (HSE)73-4309
Base Unit for the Rabbit to Fetal Pig Isolated Perfused LungHugo Sachs Elektronik (HSE)73-4138
Bovine serum A2:D41albumin lyophilized powdersigma3912500 g
Differential Low Pressure Transducer DLP2.5, Range +- 2.5 cmH2O, HSE ConnectorHugo Sachs Elektronik (HSE)73-3882
Differential Pressure Transducer MPX, Range +- 100 cmH2O, HSE ConnectorHugo Sachs Elektronik (HSE)73-0064
Ethanol absolute HPLC gradeCaledon
Harvard Peristaltic Pump P-230 (Complete with Control Box and P-230 Motor Drive)Hugo Sachs Elektronik (HSE)70-7001
Heated Linear Pneumotachometer 0 to 10 L/min flow rangeHugo Sachs Elektronik (HSE)59-9349
Heater Controller for Single Pneumotachometer 230 VAC, 50 HzHugo Sachs Elektronik (HSE)59-9703
HeparinPISA5000 UI
IPL-4 Core System for Isolated Rabbit to Fetal Pig Lung, 230 VHugo Sachs Elektronik (HSE)73-4296
Lauda Thermostatic Circulator, Type E-103, 230 V/50 Hz, 3 L Bath Volume, Temperature Range 20 to 150°CHugo Sachs Elektronik (HSE)73-0125
Negative Pressure Ventilation Control Option with Pressure Regulator for IPL-4Hugo Sachs Elektronik (HSE)73-4298
New Zeland rabbits
PISABENTAL (Pentobarbital sodium)PISAQ-7833-215
PLUGSYS Case, Type 603* 7Hugo Sachs Elektronik (HSE)73-0045
PLUGSYS TCM Time Counter ModuleHugo Sachs Elektronik (HSE)73-1750
PLUGSYS Transducer Amplifier Module (TAM-A)Hugo Sachs Elektronik (HSE)73-0065
PLUGSYS Transducer Amplifier Module (TAM-D)Hugo Sachs Elektronik (HSE)73-1793
PLUGSYS VCM-4R Ventilation Control Module with Pressure RegulatorHugo Sachs Elektronik (HSE)73-1755
PROCIN (Xylacine clorhydrate)PISAQ-7833-099
Pulmonary Artery Cannula for Rabbit with Basket, OD 4.6 mmHugo Sachs Elektronik (HSE)73-4161
Scalpel knife
Servo Controller for Perfusion (SCP)Hugo Sachs Elektronik (HSE)73-2806
Surgical gloves No. 7 1/2
Surgical gloves No. 8
Tracheal Cannula for Rabbit, OD 5.0 mmHugo Sachs Elektronik (HSE)73-4163

Odniesienia

....

Access restricted. Please log in or start a trial to view this content.

This article has been published

Video Coming Soon

Source: Pacheco-Baltazar, A., et al. Isolated Lung Perfusion System in the Rabbit Model. J. Vis. Exp. (2021)

JoVE Logo

Prywatność

Warunki Korzystania

Zasady

Badania

Edukacja

O JoVE

Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone