Overview

In this video, we demonstrate an anion-exchange chromatography technique to purify human calcium-binding protein S100A12 based on the net surface charge of the protein from an Escherichia coli culture.

Protokół

1. Protein Purification

  1. Anion-exchange chromatography
    1. Dialysis
      1. Prepare anion-exchange chromatography (AIEX) buffer A by dissolving 20 mM Tris, 1 mM EDTA and 1 mM ethylene glycol-bis(2-aminoethylether)-N, N, N', N'-tetraacetic acid (EGTA) in deionized water and adjust the pH to 8.5 with HCl. For dialysis prepare 2 x5 L and for chromatography 2x 1 L of AIEX buffer A.
        NOTE: The dialysate volume should be at about 100 times the sample volume. All buffers used for chromatography should be filtered (0.45 μm or smaller) and degassed (e.g., by ultrasonic bath or vacuum degassing).
      2. Cut dialysis tubing (molecular weight cut-off [MWCO]: 3.5 kDa) into an appropriate length with additional space for air to ensure sample buoyancy above the rotating stir bar.
        NOTE: Glycerol preserves the membrane and must be removed before use.
      3. To reduce the viscosity of the cleared protein solution, dilute the solution with 25 mL of AIEX buffer A to facilitate subsequent application to the chromatography column. Attach the first closure onto the tubing, load the sample into the membrane and attach the second closure at least 1 cm from the top end of the tubing.
      4. Place the 5 L container with AIEX buffer A on a stir plate, add a stir bar and the membrane filled with protein solution. Adjust the speed to rotate the sample by avoiding interference with the rotating stir-bar. Dialyze for 12−24 h at 4 °C, then replace the dialysate buffer (AIEX buffer A) by a fresh pre-cooled preparation and continue for at least 4 additional hours. Transfer the dialyzed protein solution to a 50 mL tube and filter through a 0.45 μm filter unit.
        NOTE: Storage possible.
    2. Chromatography
      1. Start the liquid chromatography system (FPLC) with general maintenance, connect column buffers AIEX A and AIEX B (AIEX buffer A with 1 M NaCl) and the anion-exchange resin containing column. Refer to Table 1 for general chromatographic parameters.
        NOTE: Buffers, column and FPLC equipment should be equilibrated to the same temperature before starting the run (refer to chromatographic parameters in Table 1, Table 2).
      2. Equilibrate the column with AIEX buffer A, subsequently load the sample onto the column and elute the proteins with a linear gradient from 0% to 100% high-salt buffer (AIEX B). Refer to Table 2 for a detailed method protocol.
      3. Collect 2 mL fractions during elution and analyze 10 μL of each fraction on a Coomassie-stained 15% sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Pool the fractions containing S100A12 protein for dialysis.
        NOTE: The molecular weight of S100A12 is 10,575 Da.

Wyniki

Table 1: Detailed information on the applied parameters of anion-exchange chromatography.

Bed Volume (CV)75 mL
MonitorAbsorbance at 280 nM
Pressure Max3 bar
Column buffer A20 mM Tris-HCl, 1 mM EDTA, 1 mM EGTA, pH 8.5
Column buffer ...

Ujawnienia

No conflicts of interest declared.

Materiały

NameCompanyCatalog NumberComments
25% HCl Carl Roth X897.1
4−20% Mini-PROTEAN TGX Protein Gels BioRad 4561093
Coomassie Briliant Blue R250 Destaining Solution BioRad 1610438
Coomassie Briliant Blue R250 Staining Solution BioRad 1610436
EDTA disodium salt dihydrate Carl Roth 8043.1
EGTA Carl Roth 3054.3
Q Sepharose Fast Flow GE Healthcare 17-0510-01 Resin for anion-exchange chromatography
Sodium chloride (NaCl) Carl Roth 3957.2
Sodium hydroxide Carl Roth P031.1
Tris Base Carl Roth 4855.3
0.45 µm syringe filter Merck SLHA033SS
5 L measuring beaker Carl Roth CKN3.1
50 mL conical centrifuge tubes Corning 430829
Dialysis Tubing Closures Spectrum 132738
Fraction collector tubes 5 mL Greiner 115101
Spectra/Por Dialysis Membrane (3.5 kDa)Spectrum 132724
Steritop filter unit Merck SCGPT01RE
ÄKTA purifier UPC 10 GE Healthcare FPLC System
Fraction collector GE Healthcare Frac-920
Mini Protean Tetra Cell BioRad 1658000EDU
NanoPhotometer Implen P330
pH meter Knick 765

This article has been published

Video Coming Soon

JoVE Logo

Prywatność

Warunki Korzystania

Zasady

Badania

Edukacja

O JoVE

Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone