Aby wyświetlić tę treść, wymagana jest subskrypcja JoVE. Zaloguj się lub rozpocznij bezpłatny okres próbny.
This video demonstrates a method to record CA3-CA1 synaptic responses in a rat hippocampal slice. It outlines the steps involved in placing the stimulating and recording electrodes on the hippocampal slice and measuring the field excitatory postsynaptic potential (fEPSP) to assess synaptic response strength.
All procedures involving animal samples have been reviewed and approved by the appropriate animal ethical review committee.
1. Recording of CA3-CA1 Synaptic Responses
NOTE: The electrophysiology set-up used for field potential recording is shown in Figure 1A. A Faraday cage is strongly recommended if the electrical interference is beyond the control after the proper grounding of the electrical settings. Many different types of submerged and interface chambers are commercially available. However, interface chambers are preferred as slices exhibit more robust synaptic responses in them.
Figure 1. Electrophysiology set-up for field-potential recordings consisting of (A) stimulators (b) a differential amplifier (c) an analog-to-digital converter (d) Oscilloscope (e) computer with acquisition software (f) Vibration-resistant table-top (g) microscope with >4x magnification (h) interface brain-slice chamber (i) a perfusion system for ACSF and carbo...
Name | Company | Catalog Number | Comments |
I. ACSF component chemicals | |||
1. Sodium chloride (NaCl) | Sigma-Aldrich | S5886 | |
2. Potassium chloride (KCl) | Sigma-Aldrich | P9541 | |
3. Magnesium sulphate heptahydrate (MgSO4.7H20) | Sigma-Aldrich | M1880 | |
4. Calcium chloride dihydrate (CaCl2.2H2O) | Sigma-Aldrich | C3881 | |
5. Potassium phosphate monobasic (KH2PO4) | Sigma-Aldrich | P9791 | |
6. Sodium bicarbonate (NaHCO3) | Sigma-Aldrich | S5761 | |
7. D-Glucose anhydrous (C6H12O6) | Sigma-Aldrich | G7021 | |
II. Electrophysiology Instruments | |||
1. Microscope | Olympus, Japan | Model SZ61 | |
2. Temperature Controller | Scientific Systems Design Inc. Canada | PTC03 | |
3. Differential AC Amplifier | AM Systems, USA | Model 1700 | |
4. Isolated Pulse Stimulator | AM Systems, USA | Model 2100 | |
5. Oscilloscope | Rhode & Schwarz | HM0722 | |
6. Digital-Analog Converter | Cambridge Electronic Design Ltd. Cambridge, UK | CED-Power 1401-3 | |
7. Interface Brain Slice Chamber | Scientific Systems Design Inc. Canada | BSC01 | |
8. Tubing Pump | Ismatec, Idex Health & Science, Germany | REGLO-Analog | |
9. Carbogen Flowmeter | Cole-Parmer | 03220-44 | |
10. Fiber Light Illuminator | Dolan-Jenner Industries | Fiber Lite MI-150 | |
11. Micromanipulators | Marzhauser Wetzlar, Germany | 00-42-101-0000 (MM-33) | |
00-42-102-0000 (MM-32) | |||
12. Electrodes | AM Systems, USA | 571000 (Stainless steel; 0.010, 5MΩ, 8 degree) |
This article has been published
Video Coming Soon
Source: Shetty, M. S. et al., Investigation of Synaptic Tagging/Capture and Cross-capture using Acute Hippocampal Slices from Rodents. J. Vis. Exp. (2015).
Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone