JoVE Logo

Zaloguj się

Aby wyświetlić tę treść, wymagana jest subskrypcja JoVE. Zaloguj się lub rozpocznij bezpłatny okres próbny.

W tym Artykule

  • Streszczenie
  • Protokół
  • Ujawnienia
  • Materiały
  • Odniesienia
  • Przedruki i uprawnienia

Streszczenie

Protokół

NIH3T3 cells preparation:

A. Cells for Ejection

  1. Trypsinize cells, then dilute 1:1 with cell media, and transfer from a T75 flask to a 15 mL Falcon tube
  2. Spin down cells into a pellet by centrifuging, aspirate supernatant and wash cells with DPBS
  3. Spin down cells into a pellet again, and aspirate supernatant
  4. Resuspend cells in media
  5. Determine cell density with hemocytometer (~200 X 104 cells/mL per T75 flask)
  6. Centrifuge cell solution, aspirate supernatant, and resuspend in appropriate amount of media for varying cell concentrations

B. Cell ejection

  1. Vortex cells before using for ejection
  2. Transfer 200 µL of cell solution into syringe
  3. Set appropriate mode on pulse generator
    1. For ejecting single droplets and multiple droplets (bursts), set pulse generator to "E. BUR" mode
    2. For continuous droplet ejection, set pulse generator to "NORM" mode
  4. Change signal settings
    1. Set high level and low level output voltage: HIL to 5 V and LOL to 0 V and make sure the"LIM"LED is on
    2. Set signal as a square pulse
    3. Change the amount of time the solenoid valve is open for droplet ejection by changing the value for "WID" or changing duty cycle ("DUTY")
    4. Change the frequency of ejection by changing the value for "PER"
    5. Change the number of droplets ejected in a burst by changing the value for "BUR"
  5. Eject cell solution onto prepared substrate for imaging with microscope

C. Staining

  1. Make up dye solution with 0.5 µL calcein-AM and 2 µL ethidium homodimer per mL of DPBS
  2. Immerse prepared substrate in dye solution
  3. Allow sample to incubate for 10 minutes at 37°C before imaging

Experiment Validation

  1. On a Nikon Eclipse TE-2000 U Fluorescent Microscope
    1. Spot advanced software (Diagnostics, Inc.)
    2. Live/Dead Assay

Access restricted. Please log in or start a trial to view this content.

Ujawnienia

The authors have nothing to disclose.

Materiały

NameCompanyCatalog NumberComments
Fluorescent MicroscopeNikon InstrumentsEclipse TE-2000 U
Solenoid valve cell ejectorOperation frequency: 1 KHz, 30psi, 50nl~0.5ul. 12V Valve Driver: 2.5 Amp drive current
5-Gallon Portable air tankColemanPowermate CT5Pressurized air: 30 PSI
Pressure regulatorsMarsh Bellofram
Pulse GeneratorHP8112AActuation frequency generation: 50 MHz
XYZ-stageNewmark SystemsWith Stepping motor: 6inch travel xy-stage(NLS4-6-25), 2.5inch travel z-stage(NLS4-2.5-25), 3axis controller(NSC-G3), 0.1um resolution
NIH 3T3Cell-linefibroblasts
Trypsin0.05% solution
NIH 3T3 cell medium
DPBSBuffer
T75Tissue culture flasks
Plastic conical tubes15 ml, for tissue culture

Odniesienia

Access restricted. Please log in or start a trial to view this content.

Przedruki i uprawnienia

Zapytaj o uprawnienia na użycie tekstu lub obrazów z tego artykułu JoVE

Zapytaj o uprawnienia

Przeglądaj więcej artyków

Cell EncapsulationDroplet EncapsulationDroplet based Encapsulation

This article has been published

Video Coming Soon

JoVE Logo

Prywatność

Warunki Korzystania

Zasady

Badania

Edukacja

O JoVE

Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone