Summary

The success of a time-resolved serial femtosecond crystallography experiment is dependent on efficient sample delivery. Here, we describe protocols to optimize the extrusion of bacteriorhodopsin microcrystals from a high viscosity micro-extrusion injector. The methodology relies on sample homogenization with a novel three-way coupler and visualization with a high-speed camera.

Abstract

High-viscosity micro-extrusion injectors have dramatically reduced sample consumption in serial femtosecond crystallographic experiments (SFX) at X-ray free electron lasers (XFELs). A series of experiments using the light-driven proton pump bacteriorhodopsin have further established these injectors as a preferred option to deliver crystals for time-resolved serial femtosecond crystallography (TR-SFX) to resolve structural changes of proteins after photoactivation. To obtain multiple structural snapshots of high quality, it is essential to collect large amounts of data and ensure clearance of crystals between every pump laser pulse. Here, we describe in detail how we optimized the extrusion of bacteriorhodopsin microcrystals for our recent TR-SFX experiments at the Linac Coherent Light Source (LCLS). The goal of the method is to optimize extrusion for a stable and continuous flow while maintaining a high density of crystals to increase the rate at which data can be collected in a TR-SFX experiment. We achieve this goal by preparing lipidic cubic phase with a homogenous distribution of crystals using a novel three-way syringe coupling device followed by adjusting the sample composition based on measurements of the extrusion stability taken with a high-speed camera setup. The methodology can be adapted to optimize the flow of other microcrystals. The setup will be available for users of the new Swiss Free Electron Laser facility.

Introduction

Serial femtosecond crystallography (SFX) is a structural biology technique that exploits the unique properties of X-ray free electron lasers (XFEL) to determine room temperature structures from thousands of micrometer-sized crystals while outrunning most of the radiation damage by the "diffraction before destruction" principle1,2,3.

In a time-resolved extension of SFX (TR-SFX), the femtosecond pulses from the XFEL are used to study structural changes in proteins4,5. The protein of i....

Protocol

1. Protein Crystal Sample Preparation

  1. About 30 min before the sample is to be injected, load 50 µL of crystal-laden monoolein based LCP in a 100 µL syringe.
  2. For injection at atmospheric pressure: Load 10 µL of liquid paraffin into the back of a second syringe. Holding the syringe vertically, expel the air bubbles from the syringe.
    1. For injection into vacuum environment: Load 5 µL of MAG 7.9 and 5 µL of liquid paraffin into the back of a second syringe. Holding the.......

Representative Results

The ideal starting material for the procedures described here (Figure 3) are high densities of microcrystals incorporated into viscous carrier medium for the injector. The procedure calls for about 50 µL of crystal laden carrier for each preparation. These can be grown directly in LCP as with the bR9,10 used here, as an example (Figure 4), or prepared using crystals .......

Discussion

The TR-SFX method with the viscous extrusion injector has proven to be a viable technique for structural dynamics studies of bacteriorhodopsin9,10 and photosystem II13 and now seems ready to study proteins driving other photo biological processes such as light-driven ion transport or sensory perception5,50. The protocols described above were designed to maximize the success of TR-S.......

Acknowledgements

We acknowledge Gebhard Schertler, Rafael Abela and Chris Milne for supporting the use of high viscosity injectors at the PSI. Richard Neutze and his team are acknowledged for discussions on time-resolved crystallography and sample delivery using high viscosity injectors. For financial support, we acknowledge the Swiss National Science Foundation for grants 31003A_141235, 31003A_159558 (to J.S.) and PZ00P3_174169 (to P.N.). This project has received funding from the European Union's Horizon 2020 research and innovation program under the Marie-Sklodowska-Curie grant agreement No 701646.

....

Materials

NameCompanyCatalog NumberComments
Mosquito LCP Syringe CouplingTTP labtech store3072-01050
Hamilton Syringe 1710 RNR, 100 µlHamiltonHA-81065
Hamilton Syringe 1750 RNR, 500 µlHamiltonHA-81265
MonooleinNu-Chek Prep, Inc.M-239
7.9 MAGAvanti Polar Lipids Inc.850534O
50% w/v PEG 2000Molecular DimensionsMD2-250-7
Paraffin (liquid)Sigma-Aldrich1.07162
High speed cameraPhotronPhotron Mini AX
High magnification lensNavitar12X Zoom Lens System
Three axis stageThorLabsPT3/M
Fiber lightThorlabsOSL2
Fused silica fiberMolex/PolymicroTSP-505375
Lite touch ferruleIDEXLT-100
ASU high viscosity injectorArizona State UniversityPurchasable from Uwe Weierstall (weier@asu.edu)
HPLC pumpShimadzuLC-20AD
Electronic gas regulatorProportion AirGP1

References

  1. Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., Hajdu, J. Potential for biomolecular imaging with femtosecond X-ray pulses. Nature. 406 (6797), 752-757 (2000).
  2. Chapman, H. N., et al. Femtosecond X-ray protein nanocrystallography. <....

Explore More Articles

High Viscosity ExtrusionMicrocrystalsTime resolved Serial Femtosecond CrystallographyX ray LasersLCPMonooleinMAG 7 9Liquid ParaffinSyringeCubic PhaseExtrusion TestingHPLC Pump

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved