Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be analyzed using nodal analysis.
The process begins with gathering information about the input source voltage, inductance, and capacitance values. These data points can calculate the driving voltage for the catheter's shaft. Leveraging angular frequency, inductance, and capacitance values, the impedance across the inductor and capacitor is determined, mapping out a frequency domain circuit.
KCL and Ohm's law are applied at both nodes, yielding equations that describe the system's behavior. When simplified and integrated, these equations reveal that the shaft voltage precisely equals the source voltage.
This comprehensive analysis provides essential insights into the electrical operation of the angioplasty system. The voltage data can then be converted into the time domain, allowing for assessing and optimizing the system's performance for effective plaque removal in medical procedures.
From Chapter 6:
Now Playing
AC Circuit Analysis
202 Views
AC Circuit Analysis
271 Views
AC Circuit Analysis
305 Views
AC Circuit Analysis
357 Views
AC Circuit Analysis
140 Views
AC Circuit Analysis
352 Views
AC Circuit Analysis
267 Views
AC Circuit Analysis
427 Views
AC Circuit Analysis
220 Views
AC Circuit Analysis
254 Views
AC Circuit Analysis
361 Views
AC Circuit Analysis
126 Views
AC Circuit Analysis
233 Views
AC Circuit Analysis
476 Views
AC Circuit Analysis
116 Views
See More
Copyright © 2025 MyJoVE Corporation. All rights reserved