To begin, take the isolated pig's heart and cut the branches of the aortic arch to form a single outflow tract. Insert the aortic cannula through this tract and secure it using a zip tie and 4-0 silk suture. Then place a bipolar pacing wire on the posterior wall of the right ventricle.
Create two per string 4-0 prolene sutures around the perimeter of the left atrium tract. Secure the sutures with tourniquet snares, but do not tie them until loading. Lastly, close the left atrium appendage with a simple continuous 4-0 prolene suture.
Then record the initial heart weight.