A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
Herein we report a tailored HPLC purification protocol that yields high-purity amyloid beta 42 (Aβ42) and amyloid beta 40 (Aβ40) peptides, capable of oligomer formation. Amyloid beta is a highly aggregation prone, hydrophobic peptide implicated in Alzheimer's disease. The amyloidogenic nature of the peptide makes its purification a challenge.
Amyloidogenic peptides such as the Alzheimer's disease-implicated Amyloid beta (Aβ), can present a significant challenge when trying to obtain high purity material. Here we present a tailored HPLC purification protocol to produce high-purity amyloid beta 42 (Aβ42) and amyloid beta 40 (Aβ40) peptides. We have found that the combination of commercially available hydrophobic poly(styrene/divinylbenzene) stationary phase, polymer laboratory reverse phase - styrenedivinylbenzene (PLRP-S) under high pH conditions, enables the attainment of high purity (>95%) Aβ42 in a single chromatographic run. The purification is highly reproducible and can be amended to both semi-preparative and analytical conditions depending upon the amount of material wished to be purified. The protocol can also be applied to the Aβ40 peptide with identical success and without the need to alter the method.
مرض الزهايمر هو اضطراب الاعصاب الذي آثار أكثر من 35 مليون شخص في جميع أنحاء العالم. 1 متورط بشدة في بداية وتطور هذا المرض، هو غاية تجميع عرضة، الببتيد مسعور اميلويد بيتا (Aβ). يتراوح 2 Aβ 36-43 الأحماض الأمينية في الطول، ولكن يعتقد أن 42 الأحماض الأمينية البديل، اميلويد بيتا 42 (Aβ42)، هو الشكل الأكثر سمية من البروتين. 3 ويرجع في معظم جزئيا إلى قدرة Aβ42 لتشكيل بسهولة قابل للانتشار، والأنواع بلازميدة قليلة القسيمات التي يعتقد أن تكون الكيانات السمية العصبية بشكل خاص. 4 من أجل تعزيز فهمنا للالببتيد Aβ، فمن الضروري الحصول بشكل روتيني المواد عالية النقاء. وقد تبين وجود شوائب التتبع إلى تغيير كبير في خصائص تجميع ميل الببتيد. 5
تيraditionally، وقد تم ذلك السائل اللوني (HPLC) فصل عالية الأداء من الببتيدات مسعور مثل Aβ من خلال استخدام مزيج من C 4 أو C 8 الأطوار الثابتة القائمة على السيليكا والطور المتحرك الحمضية. 6 ومع ذلك، يمكن لمثل هذه الظروف تحديا لتنقية الببتيد. نقطة تساوي الكهربية منخفضة من الببتيد Aβ (PI ما يقرب من 5.5) 7 يعني أنه في ظل الظروف الحمضية، يتم زيادة الببتيد تجميع ونتيجة لذلك يتم إنتاج واسعة، غير حلها، قمم HPLC التي غالبا ما تكون صعبة لعزل (الشكل 2A). وعلاوة على ذلك، فإن مثل هذه القمم واسعة غالبا ما تحتوي على الشوائب التي قد تؤثر على الشخصية تجميع الببتيد، وعادة تتطلب الجولات اللاحقة من تنقية والتي يمكن أن تؤثر بشكل كبير على كمية من الببتيد المنتجة.
بولي (الستايرين / divinylbenzene) مرحلة ثابتة، PLRP-S، يمثل وسيلة بديلة لpurifيينغ الببتيدات مسعور. وقد استخدمت في مرحلة ثابتة في تنقية عدد من البروتينات المختلفة ورسوله الأحماض النووي الريبي (مرنا). 8، 9 مرحلة ثابتة PLRP-S يتطلب أي يجند ألكيل إضافي للفصل المرحلة العكسي، والأهم من ذلك هو مستقر كيميائيا عند درجة الحموضة العالية الأمر الذي يؤدي إلى deaggregation من الببتيد. 7 هنا، نحن الإبلاغ عن مصممة بروتوكول تنقية HPLC أن ينتج عالية النقاء اميلويد بيتا 42 (Aβ42) وبيتا 40 الببتيدات (Aβ40) اميلويد.
1. Preparative HPLC Purification of the Aβ40 or Aβ42 Peptide
Figure 1: Experimental setup of the HPLC instrument used for purification of the amyloid beta peptides. (A) The quaternary HPLC pump fitted with a degasser and variable wavelength detector set to 214 nm and 280 nm; (B) HPLC columns used for purification of the amyloid beta peptides, from left to right, 25 x 300 mm2 preparative column, 7.5 x 300 mm2 semi preparative column and 4.6 x 250 mm2 analytical column; (C) Manual injector with 20 µL stainless steel injection loop used for analytical HPLC; (D) Manual injector with 10 mL stainless steel injection loop used for preparative and semi preparative purification. Please click here to view a larger version of this figure.
Time / min | % of Buffer Aa | % of Buffer Bb | Flow Rated / mL min-1 |
0 | 80 | 20 | 6 |
45 | 75.5 | 24.5 | 6 |
45.01 | 80 | 20 | 6 |
52.01 | 80 | 20 | 6 |
52.02 | 73 | 27 | 6 |
85 | 73 | 27 | 6 |
92 | 5 | 95c | 6 |
Table 1: Timetable for the purification of the Aβ42 and Aβ40 peptides using the 25 × 300 mm polymer column. aBuffer A - H2O with 20 mM NH4OH; b80% MeCN / 20% H2O with 20 mM NH4OH; cRan for 15 min to wash the column prior to the next injection of sample; dIn order to run a flow rate of 6 mL/min on the HPLC instrumentation, the pressure limit needs to be reduced to 200 bar.
2. Analytical HPLC Analysis of the Purified Aβ Protein
Time / min | % of Buffer Aa | % of Buffer Bb | Flow Rate / mL min-1 |
0 | 95 | 5 | 1 |
30 | 50 | 50 | 1 |
Table 2: Timetable for the HPLC purity analysis of the Aβ peptide. aBuffer A - H2O with 20 mM NH4OH; b80% MeCN / 20% H2O with 20 mM NH4OH.
Figure 2: Representative HPLC traces of Aβ42. (A) Traditional C4 silica purification, conditions: Buffer A: H2O with 0.1% trifluoroacetic acid (TFA), buffer B: MeCN (acetonitrile) with 0.1% TFA, gradient: 20 to 27% buffer B over 40 min followed by isocratic 27% buffer B; (B) Preparative purification using the 25 x 300 mm2 polymer column, conditions: Buffer A: H2O with 20 mM NH4OH, buffer B: 80% MeCN / 20% H2O with 20 mM NH4OH, gradient: 20 to 27% buffer B over 70 min followed by isocratic 27% buffer B; (C) Optimized preparative purification using the 25 x 300 mm2 polymer column, conditions are described in Table 1 located in sub-section 1.3 of the protocol description text; (D) Analytical HPLC using the 4.6 x 250 mm2 polymer column, conditions: Buffer A: H2O with 20 mM NH4OH, buffer B: 80% MeCN / 20% H2O with 20 mM NH4OH, gradient-5 to 50% buffer B over 30 min. For parts A, B and C the peak corresponding to Aβ42 is marked by an asterisk. Collection of the marked Aβ42 peak in part C reveals a purity of >95% as shown in part D. Mass spectrometry was used to determine the identity of the Aβ42 peak. Please click here to view a larger version of this figure.
The purification of the Aβ42 peptide using a combination of the PLRP-S stationary phase and a high pH mobile phase results in the formation of a sharp, resolved peak for the Aβ peptide at a retention time between 72 and 74 min (Figure 2C). Confirmation of the identity of the peak is done through direct injection mass spectrometry of the collected eluent. The eluent can be stored at -20 °C in solution for up to 12 h. Longer periods of storage may result in o...
The HPLC purification of the Aβ peptide is highly dependent upon the choice of both the stationary phase employed in the purification and the mobile phase chosen to elute the peptide. The low isoelectric point of the peptide and high propensity for aggregation render traditional chromatographic conditions for the separation of hydrophobic proteins (C4 or C8 stationary phase coupled with an acidic mobile eluent) challenging, with the Aβ peptide eluting as a prolonged broad, non-resolved peak (Figure 2A
The authors have nothing to disclose.
The authors would like to thank Agilent for their technical assistance. Kate Markham and Rafael Palomino are credited for their initial help in the synthesis and purification of the Aβ peptide and Dr Hsiau-Wei Lee is thanked for his help in preparing Figure 1 of the manuscript.
Name | Company | Catalog Number | Comments |
Agilent 1260 Infinity II quarternary pump | Agilent | G7111B | http://www.agilent.com/en-us/products/liquid-chromatography/lc-pumps-vacuum-degassers/1260-infinity-ii-quaternary-pump |
Agilent 1260 Infinity II Dual variable wavelength detector | Agilent | G7114A | http://www.agilent.com/en-us/products/liquid-chromatography/lc-detectors/1260-infinity-ii-variable-wavelength-detector |
Agilent 1260 Infinity II Manual Injector fitted with 10 mL stainless steel sample loop | Agilent | 0101-1232 | http://www.agilent.com/en-us/products/liquid-chromatography/lc-injection-systems/1260-infinity-ii-manual-injector |
Agilent 1260 Infinity II Manual Injector fitted with 20 µL stainless steel sample loop | Agilent | G1328C | http://www.agilent.com/en-us/products/liquid-chromatography/lc-injection-systems/1260-infinity-ii-manual-injector |
Ring Stand Mounting Bracket | Agilent | 1400-3166 | |
Agilent PLRP-S 300 Å 5 µm 4.6 x 250 mm (Analytical) | Agilent | PL1512-5501 | http://www.agilent.com/en-us/products/liquid-chromatography/lc-columns/biomolecule-separations/plrp-s-for-biomolecules#features |
Aβ42 or Aβ40 peptide | Synthesized in-house using a CEM liberty automated peptide synthesizer. | ||
Ammonium Hydroxide (NH4OH, 28% solution) | Fisher Scientific | A669-500 | |
Acetonitrile | Fisher Scientific | A998-4 | |
HPLC grade water | Fisher Scientific | W5-4 | |
Falcon 50 mL conical centrifuge tube | Fisher Scientific | 14-954-49A | |
Supelco PEEK Fitting One-piece fingertight, pkg of 5 ea | Sigma-Aldrich | Z227250 | |
Normject 5 cc sterile syringe | Fisher Scientific | 1481729 | |
16 Gauge SS Needle | Rheodyne | 3725-086 |
Request permission to reuse the text or figures of this JoVE article
Request PermissionThis article has been published
Video Coming Soon
Copyright © 2025 MyJoVE Corporation. All rights reserved