Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.

A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating material features a high boiling point, low viscosity, and low polarity and functions as the stationary phase of the chromatograph. The analyte is injected into one end of the column and flushed through the column using an inert gas flow as the mobile phase. The boiling point of each compound and its interaction with the stationary phase determines the speed of movement through the column. Consequently, each compound in the mixture reaches the other end of the column at a different time. Eventually, the mass spectrometer connected to the column's end analyzes each compound separately.

Tags
Gas ChromatographyMass SpectrometryGC MSAnalytical TechniquesCapillary ColumnPolysiloxane CoatingStationary PhaseMobile PhaseMolecular MassesMolecular StructuresAnalyte InjectionInert Gas FlowCompound Separation

Del capítulo 6:

article

Now Playing

6.12 : Gas Chromatography–Mass Spectrometry (GC–MS)

Principles of Mass Spectrometry

3.6K Vistas

article

6.1 : Mass Spectrometry: Overview

Principles of Mass Spectrometry

3.4K Vistas

article

6.2 : Mass Spectrometry: Isotope Effect

Principles of Mass Spectrometry

1.7K Vistas

article

6.3 : Mass Spectrometry: Molecular Fragmentation Overview

Principles of Mass Spectrometry

2.7K Vistas

article

6.4 : Mass Spectrometers

Principles of Mass Spectrometry

4.6K Vistas

article

6.5 : Mass Spectrum

Principles of Mass Spectrometry

1.5K Vistas

article

6.6 : Mass Spectrum: Interpretation

Principles of Mass Spectrometry

1.0K Vistas

article

6.7 : Mass Analyzers: Overview

Principles of Mass Spectrometry

515 Vistas

article

6.8 : Mass Analyzers: Common Types

Principles of Mass Spectrometry

510 Vistas

article

6.9 : High-Resolution Mass Spectrometry (HRMS)

Principles of Mass Spectrometry

1.1K Vistas

article

6.10 : Mass Spectrometry: Complex Analysis

Principles of Mass Spectrometry

637 Vistas

article

6.11 : Tandem Mass Spectrometry

Principles of Mass Spectrometry

730 Vistas

article

6.13 : Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

Principles of Mass Spectrometry

536 Vistas

article

6.14 : Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Principles of Mass Spectrometry

302 Vistas

JoVE Logo

Privacidad

Condiciones de uso

Políticas

Investigación

Educación

ACERCA DE JoVE

Copyright © 2025 MyJoVE Corporation. Todos los derechos reservados