Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.

A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating material features a high boiling point, low viscosity, and low polarity and functions as the stationary phase of the chromatograph. The analyte is injected into one end of the column and flushed through the column using an inert gas flow as the mobile phase. The boiling point of each compound and its interaction with the stationary phase determines the speed of movement through the column. Consequently, each compound in the mixture reaches the other end of the column at a different time. Eventually, the mass spectrometer connected to the column's end analyzes each compound separately.

Etiketler

Gas ChromatographyMass SpectrometryGC MSAnalytical TechniquesCapillary ColumnPolysiloxane CoatingStationary PhaseMobile PhaseMolecular MassesMolecular StructuresAnalyte InjectionInert Gas FlowCompound Separation

Bölümden 6:

article

Now Playing

6.12 : Gas Chromatography–Mass Spectrometry (GC–MS)

Principles of Mass Spectrometry

3.6K Görüntüleme Sayısı

article

6.1 : Mass Spectrometry: Overview

Principles of Mass Spectrometry

3.4K Görüntüleme Sayısı

article

6.2 : Mass Spectrometry: Isotope Effect

Principles of Mass Spectrometry

1.7K Görüntüleme Sayısı

article

6.3 : Mass Spectrometry: Molecular Fragmentation Overview

Principles of Mass Spectrometry

2.7K Görüntüleme Sayısı

article

6.4 : Mass Spectrometers

Principles of Mass Spectrometry

4.6K Görüntüleme Sayısı

article

6.5 : Mass Spectrum

Principles of Mass Spectrometry

1.5K Görüntüleme Sayısı

article

6.6 : Mass Spectrum: Interpretation

Principles of Mass Spectrometry

1.0K Görüntüleme Sayısı

article

6.7 : Mass Analyzers: Overview

Principles of Mass Spectrometry

515 Görüntüleme Sayısı

article

6.8 : Mass Analyzers: Common Types

Principles of Mass Spectrometry

510 Görüntüleme Sayısı

article

6.9 : High-Resolution Mass Spectrometry (HRMS)

Principles of Mass Spectrometry

1.1K Görüntüleme Sayısı

article

6.10 : Mass Spectrometry: Complex Analysis

Principles of Mass Spectrometry

637 Görüntüleme Sayısı

article

6.11 : Tandem Mass Spectrometry

Principles of Mass Spectrometry

730 Görüntüleme Sayısı

article

6.13 : Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

Principles of Mass Spectrometry

536 Görüntüleme Sayısı

article

6.14 : Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Principles of Mass Spectrometry

302 Görüntüleme Sayısı

JoVE Logo

Gizlilik

Kullanım Şartları

İlkeler

Araştırma

Eğitim

JoVE Hakkında

Telif Hakkı © 2020 MyJove Corporation. Tüm hakları saklıdır