Building separation joints divide large or complex building structures into smaller, discrete units that can move independently. These joints are categorized into three types: volume-change joints, settlement joints, and seismic separation joints.

Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200 feet apart in elongated structures, with spacing tailored to the material properties and the extent of dimensional changes expected.

Settlement joints are used to prevent structural distress that can occur from differential settlement rates in different parts of a building. This situation can arise in structures with varying foundation types or those built on different soil conditions.

Seismic separation joints are specifically designed for buildings in earthquake-prone areas. These joints divide the building into smaller segments to ensure that each part can move independently during seismic events, minimizing the risk of damage.

Overall, building separation joints are implemented by constructing independent structures on either side of the joint, sometimes with completely separate foundations and structural elements, ensuring manageable movement in response to various forces.

Tags

Building Separation JointsVolume change JointsSettlement JointsSeismic Separation JointsIndependent StructuresStructural DistressDifferential SettlementEarthquake prone AreasDimensional ChangesFoundation TypesSoil ConditionsConstruction Design

Del capítulo 2:

article

Now Playing

2.10 : Types of Building Separation Joints

Masonry

153 Vistas

article

2.1 : Composite Masonry Walls

Masonry

412 Vistas

article

2.2 : Masonry Cavity Walls

Masonry

326 Vistas

article

2.3 : Masonry Loadbearing Walls

Masonry

80 Vistas

article

2.4 : Masonry Curtain Walls

Masonry

372 Vistas

article

2.5 : Posttensioned Masonry Walls

Masonry

92 Vistas

article

2.6 : Cavity Drainage and Flashings in Masonry walls

Masonry

56 Vistas

article

2.7 : Thermal Insulation in Masonry Walls

Masonry

92 Vistas

article

2.8 : Expansion and Contraction in Masonry Walls

Masonry

283 Vistas

article

2.9 : Movement Joints in Buildings

Masonry

87 Vistas

article

2.11 : Efflorescence in Masonry

Masonry

55 Vistas

article

2.12 : Mortar Joint Deterioration in Masonry

Masonry

88 Vistas

article

2.13 : Masonry in Cold and Hot Weather Conditions

Masonry

63 Vistas

article

2.14 : Masonry Paving

Masonry

228 Vistas

JoVE Logo

Privacidad

Condiciones de uso

Políticas

Investigación

Educación

ACERCA DE JoVE

Copyright © 2025 MyJoVE Corporation. Todos los derechos reservados