Determination of Impingement Forces on a Flat Plate with the Control Volume Method

Visión general

Source: Ricardo Mejia-Alvarez and Hussam Hikmat Jabbar, Department of Mechanical Engineering, Michigan State University, East Lansing, MI

The purpose of this experiment is to demonstrate forces on bodies as the result of changes in the linear momentum of the flow around them using a control volume formulation [1, 2]. The control volume analysis focuses on the macroscopic effect of flow on engineering systems, rather than the detailed description that could be achieved with a differential analysis. Each one of these two techniques have a place in the toolbox of an engineering analyst, and they should be considered complementary rather than competing approaches. Broadly speaking, control volume analysis will give the engineer an idea of the dominant loads in a system. This will give her/him an initial feeling about what route to pursue when designing devices or structures, and should ideally be the initial step to take before pursuing any detailed design or analysis via differential formulation.

The main principle behind the control volume formulation is to replace the details of a system exposed to a fluid flow by a simplified free body diagram defined by an imaginary closed surface dubbed the control volume. This diagram should contain all surface and body forces, the net flux of linear momentum through the boundaries of the control volume, and the rate of change of linear momentum inside the control volume. This approach implies cleverly defining the control volume in ways that simplify the analysis at the same time that capture the dominant effects on the system. This technique will be demonstrated with a plane jet impinging on a flat plate at different angles. We will use control volume analysis to estimate the aerodynamic load on the plate, and will compare our results with actual measurements of the resulting force obtained with an aerodynamic balance.

Procedimiento

1. Setting the facility

  1. Make sure that there is no flow in the facility.
  2. Connect the positive port of the pressure transducer to the plenum pressure tap ().
  3. Leave the negative port of the pressure transducer open to the atmosphere ().
  4. Record the transducer's conversion factor from Volts to Pascals ().
  5. Record the

Log in or to access full content. Learn more about your institution’s access to JoVE content here

Resultados

Figure 3 shows a comparison between the normal load on the flat plate as measured directly from an aerodynamic balance and estimated from conservation of linear momentum. In general, the analysis of linear momentum captured the dominant tendency of direct measurements as the impingement angle changes. The discrepancies in these measurements varied non-monotonically with the impingement angle. For impingement angles in the range

Log in or to access full content. Learn more about your institution’s access to JoVE content here

Aplicación y resumen

We demonstrated the application of control volume analysis of conservation of linear momentum to determine the forces exerted by a jet impinging on a flat plate. This analysis proved simple to apply, and gave a satisfactory bulk estimation of loads without requiring detailed knowledge of the flow pattern around the plate. Though there were some discrepancies (both in magnitude as well as tendency) due to the basic assumption of inviscid transformation of momentum, this technique offers a means of obtaining a quick estima

Log in or to access full content. Learn more about your institution’s access to JoVE content here

Referencias
  1. White, F. M. Fluid Mechanics, 7th ed., McGraw-Hill, 2009.
  2. Munson, B.R., D.F. Young, T.H. Okiishi. Fundamentals of Fluid Mechanics. 5th ed., Wiley, 2006.
  3. Buckingham, E. Note on contraction coefficients of jets of gas. Journal of Research,6:765-775, 1931.
  4. Lienhard V, J.H. and J.H. Lienhard IV. Velocity coefficients for free jets from sharp-edged orifices. ASME Journal of Fluids Engineering, 106:13-17, 1984.
Tags
Control Volume MethodImpingement ForcesFlat PlateFluid EngineeringAerodynamic DesignLinear MomentumWind Turbine BladeBoat SailAirplane WingEngineering AnalystFeasibility PredictionStructure CalculationControl Volume AnalysisControl SurfaceSurface ForcesPressure ForcesFlow induced Shear Forces

Saltar a...

0:07

Overview

1:08

Principles of Control Volume Analysis

5:45

Setup and Calibration

7:01

Data Acquisition

7:57

Data Analysis

8:53

Results

10:03

Applications

11:01

Summary

Vídeos de esta colección:

article

Now Playing

Determination of Impingement Forces on a Flat Plate with the Control Volume Method

Mechanical Engineering

25.9K Vistas

article

Flotabilidad y arrastre en cuerpos sumergidos

Mechanical Engineering

29.8K Vistas

article

Estabilidad de los buques flotantes

Mechanical Engineering

22.3K Vistas

article

Propulsión y empuje

Mechanical Engineering

20.8K Vistas

article

Redes de tuberías y pérdidas de presión

Mechanical Engineering

57.8K Vistas

article

Enfriamiento y ebullición

Mechanical Engineering

7.7K Vistas

article

Saltos hidráulicos

Mechanical Engineering

40.8K Vistas

article

Análisis del intercambiador de calor

Mechanical Engineering

27.9K Vistas

article

Introducción a la refrigeración

Mechanical Engineering

24.6K Vistas

article

Anemometría de hilo caliente

Mechanical Engineering

15.5K Vistas

article

Medición de flujos turbulentos

Mechanical Engineering

13.4K Vistas

article

Visualización de flujo más allá de un cuerpo no fuselado

Mechanical Engineering

11.7K Vistas

article

Jet que inciden sobre una placa inclinada

Mechanical Engineering

10.7K Vistas

article

Enfoque de conservación de la energía para el análisis de sistemas

Mechanical Engineering

7.3K Vistas

article

Conservación de masa y mediciones de tasa de flujo

Mechanical Engineering

22.6K Vistas

JoVE Logo

Privacidad

Condiciones de uso

Políticas

Investigación

Educación

ACERCA DE JoVE

Copyright © 2025 MyJoVE Corporation. Todos los derechos reservados