S'identifier

When an RL (Resistor-Inductor) circuit is connected to a DC source, the complete response of the circuit can be divided into two parts: the transient response and the steady-state response.

The transient response of the circuit is its temporary reaction to the sudden application of the DC source. This response is characterized by a current that exponentially decays to zero as time approaches infinity. During this transitional period, the inductor behaves like a short circuit, causing the source voltage to drop across the resistor.

Once the transient response has decayed to zero, the circuit enters its steady-state phase. In this phase, the current in the circuit becomes stable, equaling the ratio of the source voltage to the resistance of the circuit. This is the steady-state response.

The constant term in the transient response can be determined by substituting the initial current through the inductor at the time the switch is closed (t=0). This gives us the initial condition for the transient response.

Plotting the complete step response of the circuit shows that the initial current decreases exponentially until it reaches a steady-state value. From this current response, the voltage response is derived, which also follows an exponential decay from a maximum value to zero.

If the initial current in the circuit is zero, the complete step response shows the current increasing exponentially until it reaches the steady-state value. Correspondingly, the voltage response starts at the source voltage and decreases exponentially to zero.

In conclusion, understanding the complete response of an RL circuit to a DC source provides valuable insights into how these circuits react to sudden changes in input voltage. This knowledge is essential for designing and analyzing electronic circuits, particularly in applications such as power supply filtering and signal processing, where inductors are used extensively.

Tags
RL CircuitResistor InductorTransient ResponseSteady state ResponseDC SourceCurrent DecayVoltage ResponseInitial ConditionExponential DecayStep ResponseElectronic CircuitsPower Supply FilteringSignal Processing

Du chapitre 5:

article

Now Playing

5.5 : RL Circuit with Source

First and Second-Order Circuits

587 Vues

article

5.1 : First-Order Circuits

First and Second-Order Circuits

1.1K Vues

article

5.2 : RC Circuit without Source

First and Second-Order Circuits

784 Vues

article

5.3 : RC Circuit with Source

First and Second-Order Circuits

731 Vues

article

5.4 : RL Circuit without Source

First and Second-Order Circuits

720 Vues

article

5.6 : Design Example: Frog Muscle Response

First and Second-Order Circuits

154 Vues

article

5.7 : Second-Order Circuits

First and Second-Order Circuits

1.1K Vues

article

5.8 : Series RLC Circuit without Source

First and Second-Order Circuits

877 Vues

article

5.9 : Types of Responses of Series RLC Circuits

First and Second-Order Circuits

668 Vues

article

5.10 : Series RLC Circuit with Source

First and Second-Order Circuits

248 Vues

article

5.11 : Parallel RLC Circuits

First and Second-Order Circuits

650 Vues

article

5.12 : Second-order Op Amp Circuits

First and Second-Order Circuits

198 Vues

article

5.13 : Design Example: Underdamped Parallel RLC Circuit

First and Second-Order Circuits

183 Vues

JoVE Logo

Confidentialité

Conditions d'utilisation

Politiques

Recherche

Enseignement

À PROPOS DE JoVE

Copyright © 2025 MyJoVE Corporation. Tous droits réservés.