JoVE Logo

Accedi

È necessario avere un abbonamento a JoVE per visualizzare questo. Accedi o inizia la tua prova gratuita.

In questo articolo

  • Overview
  • Protocollo
  • Divulgazioni
  • Materiali
  • Riferimenti

Overview

This video shows an ex vivo technique for isolated lung perfusion. It is a tool for pulmonary research that will aid studies of various physiological and pathological mechanisms involved in lung transplantation procedures.

Protocollo

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Cannulation:

  1. Place the freshly isolated rabbit's lungs along with heart over a sterile gauze on a petri dish.
  2. To prevent atelectasis, ventilate the lungs using positive-pressure ventilation with positive end-expiratory pressure (PEEP) set at 2 cmH2O.
  3. Remove the ventricles by cutting them off the heart at the level of the atrioventricular groove.
  4. After opening the two ventricles, introduce the OD 4.6 mm pulmonary artery cannula for the rabbit with a basket through the pulmonary artery and introduce the OD 5.9 mm left atrium cannula for the rabbit with the basket through the mitral valve into the left atrium.
  5. Use a 4-0 silk suture in the pulmonary artery and left atrium to fix the cannulae. Include the surrounding tissues in the ligatures of the pulmonary artery and left atrium to avoid the distension of these structures.
  6. Inject 250 mL of saline isotonic solution through the arterial cannulae to flush the remaining blood from the vascular bed.

2. Perfusion technique:

  1. Setup:
    1. Place the isolated lungs carefully into the lung chamber.
    2. Attach the trachea to the transductor on the cover of the chamber.
    3. Connect the cannulated vessels to the perfusion system.
    4. Close the chamber and secure it with the rotary lock.
      NOTE: The recirculating perfusion circuit consists of an open venous reservoir, a peristaltic pump, a heat exchanger, and a bubble trap.
    5. At this point, attach the chamber lid and switch over a stopcock to switch from positive to negative pressure ventilation. To check the negative pressure ventilation of the lungs and airtight closure of the chamber, inspect the respiratory excursion of the lung and chamber pressure on the pressure gauge.
    6. Perfuse the lungs with 200 mL of artificial blood-free perfusate (a Krebs-Ringer bicarbonate buffer containing 2.5% of bovine albumin).
    7. Start the perfusate flow at 3 mL/min/kg, then slowly step up the flow over a 5-min period to 5 mL/min/kg. Reach a flow of 8 mL/min/kg over the next 5 min and then after another 5-min period reach a maximum flux of 10 mL/min/kg. Take care of avoiding air from getting into the circuit.
      NOTE: Maintain the pH and the temperature of the perfusate within physiological ranges (pH 7.4-7.5; temperature, 37 °C-38 °C). To adjust the pH, add NaHCO3 (1N) or increase the flow of carbon dioxide. Alternatively, use HCl (0.1N) to acidify.
  2. Parameters:
    1. Check whether the predetermined perfusion and ventilation parameters are set as required.
    2. Ventilate the lungs with humidified air at a frequency of 30 bpm, a tidal volume of 10 mL/kg, and an end-expiratory pressure (Pe) of 2 cmH2O.
      NOTE: The pulmonary arterial pressure (0-20 mmHg) corresponds to the height of the liquid level in the oxygenator or reservoir in centimeters above the pulmonary trunk, while the pulmonary venous pressure corresponds to the height of the pressure equilibration chamber above the left atrium. Both values can be modified. Note that left atrium pressure is also 0-20 mmHg.
  3. Achieving zone 3 conditions:
    1. Use the two catheters connected to side ports of the cannulae secured in the pulmonary artery, left atrium, and pressure transducers to measure the arterial (Pa) and venous (Pv) pressures.
    2. Set the baseline pressures at the level of the lung hilum (Zero-reference).
    3. Conduct the experiments under zone 3 ventilation conditions. To achieve this, wait for 10-15 min to obtain an equilibrium characterized by an isogravimetric state.
    4. Ensure that the venous pressure is higher than the alveolar pressure (Palv) and the arterial pressure remains higher than both (Pa > Pv > Palv) for Zone 3 conditions to occur.
    5. Ensure that the lungs' weight remains constant and arterial and left atrial pressures are stable to achieve zone 3 conditions to open up a maximum number of pulmonary vessels and maintain the microvascular bed content during the experiment. 
      NOTE: The measurement of Kfc as an indicator of pulmonary edema has no variation between a manual and an automatic perfusion system.
  4. Electronic control and signal processing: Ensure that the respiratory flow, weight changes, microvascular pressure, tidal volume, vascular resistance, among others, are registered on a multiple central electronics unit that integrates signals coming from the transducers and displays them on the evaluation system.

Divulgazioni

No conflicts of interest declared.

Materiali

NameCompanyCatalog NumberComments
2-Stop Tygon E-Lab Tubing, 3.17 mm ID, 12/pack, Black/WhiteHugo Sachs Elektronik (HSE)73-1864
Adapter for Positive Pressure Ventilation on IPL-4Hugo Sachs Elektronik (HSE)73-4312
Adapter for Positive Pressure Ventilation on IPL-4Hugo Sachs Elektronik (HSE)73-4312
Alternative Pressure-Free Gas Supply for IPL-4: To supply the trachea with gas mixture different from room air during negative ventilationHugo Sachs Elektronik (HSE)73-4309
Base Unit for the Rabbit to Fetal Pig Isolated Perfused LungHugo Sachs Elektronik (HSE)73-4138
Bovine serum A2:D41albumin lyophilized powdersigma3912500 g
Calcium chloride, CaCl2·2H2O.JT Baker10035-04-8
Cryogenic vialsCorning4306592 mL
D-glucose, C6H12O6.sigmaG5767
Differential Low Pressure Transducer DLP2.5, Range +- 2.5 cmH2O, HSE ConnectorHugo Sachs Elektronik (HSE)73-3882
Differential Pressure Transducer MPX, Range +- 100 cmH2O, HSE ConnectorHugo Sachs Elektronik (HSE)73-0064
Eppendorf tubes
Ethanol absolute HPLC gradeCaledon
Falcon tubes14 mL
Harvard Peristaltic Pump P-230 (Complete with Control Box and P-230 Motor Drive)Hugo Sachs Elektronik (HSE)70-7001
Heated Linear Pneumotachometer 0 to 10 L/min flow rangeHugo Sachs Elektronik (HSE)59-9349
Heater Controller for Single Pneumotachometer 230 VAC, 50 HzHugo Sachs Elektronik (HSE)59-9703
HeparinPISA5000 UI
HPLC Column (C18 100A 5U)Alltech98121213150 mm x 4.6 mm
Hydrophilic Syringe FilterMillexSLLGR04NL4 mm
IPL-4 Core System for Isolated Rabbit to Fetal Pig Lung, 230Hugo Sachs Elektronik (HSE)73-4296
IPL-4 Core System for Isolated Rabbit to Fetal Pig Lung, 230 VHugo Sachs Elektronik (HSE)73-4296
Jacketed Glass Reservoir for Buffer Solution, with Frit and Tubing, 6.0 LHugo Sachs Elektronik (HSE)73-0322
Lauda Thermostatic Circulator, Type E-103, 230 V/50 Hz, 3 L Bath Volume, Temperature Range 20 to 150°CHugo Sachs Elektronik (HSE)73-0125
Left Atrium Cannula for Rabbit with Basket, OD 5.9 mmHugo Sachs Elektronik (HSE)73-4162
Low Range Blood Pressure Transducer P75 for PLUGSYS ModuleHugo Sachs Elektronik (HSE)73-0020
Magnesium sulfate heptahydrate, MgSO4·7H2OJT Baker10034-99-8
Microcentrifuge TubeCorning430909
Negative Pressure Ventilation Control Option with Pressure Regulator for IPL-4Hugo Sachs Elektronik (HSE)73-4298
New Zeland rabbits
PISABENTAL (Pentobarbital sodium)PISAQ-7833-215
PLUGSYS Case, Type 603* 7Hugo Sachs Elektronik (HSE)73-0045
PLUGSYS TCM Time Counter ModuleHugo Sachs Elektronik (HSE)73-1750
PLUGSYS Transducer Amplifier Module (TAM-A)Hugo Sachs Elektronik (HSE)73-0065
PLUGSYS Transducer Amplifier Module (TAM-D)Hugo Sachs Elektronik (HSE)73-1793
PLUGSYS VCM-4R Ventilation Control Module with Pressure RegulatorHugo Sachs Elektronik (HSE)73-1755
Potassium chloride, KCl.JT Baker3040-01
Potassium dihydrogen phosphate, KH2PO4JT Baker7778-77-0
Pulmonary Artery Cannula for Rabbit with Basket, OD 4.6 mmHugo Sachs Elektronik (HSE)73-4161
Servo Controller for Perfusion (SCPHugo Sachs Elektronik (HSE)73-2806
Snap Cap Microcentrifuge TubeCostar36201.7 mL
Sodium bicarbonate, NaHCO3sigmaS6014
Sodium chloride, NaCl.sigmaS9888
Surgical gloves No. 7 1/2
Surgical gloves No. 8
Taygon tubesMasterflex
Tracheal Cannula for Rabbit, OD 5.0 mmHugo Sachs Elektronik (HSE)73-4163

Riferimenti

This article has been published

Video Coming Soon

Source: Pacheco-Baltazar, A., et al., Isolated Lung Perfusion System in the Rabbit Model. J. Vis. Exp. (2021).

JoVE Logo

Riservatezza

Condizioni di utilizzo

Politiche

Ricerca

Didattica

CHI SIAMO

Copyright © 2025 MyJoVE Corporation. Tutti i diritti riservati