In this video, the effects of transcranial direct-current stimulation (tDCS) on brain slices containing the anterior cingulate cortex (ACC) and thalamus regions are investigated, using a multi-electrode array (MEA) to measure electric signals. By delivering electric pulses and infusing seizure-inducing drugs, the study investigates the ACC response to seizures.
All procedures involving animal samples have been reviewed and approved by the appropriate animal ethical review committee.
1. Preparing Experimental Solution and Equipment for MEA (Multielectrode Array) Recording
2. Brain Slice Preparation
3. Preparation of Perfusion Chamber for Multielectrode Array Recording
4. Generation of Electric Fields by DCS
Note: The definition of the electric field orientation was based on the direction of the axodendritic axis in the ACC. The orientations of dendrite and soma compartments were confirmed using Golgi staining12.
5. Electrically-induced Cortical Synaptic Responses
Note: Induce synaptic responses in the ACC by electrical stimulation in the MT, in which a programmable electrical stimulus generator produces rectangular biphasic current pulses.
6. Electrically-induced Seizure-like Activity
Note: Seizure-like activity was induced by the application of 4-aminopyridine (4-AP; 250 µM) and bicuculline (5 µM). Previous time-control studies showed that maximal and stable responses appeared 2-3 hr after drug application14.
Figure 1: Preparation of the Thalamocingulate Slice and MEA Recording System Setup. (A) MT-ACC slice procedure (a) Remove the brain and (b) transfer to cool oxygenated aCSF. (c) Make two parasagittal cuts from the midline. (d) Side view of the medial part of the brain block. (e) Make two angled ventral cuts of the brain block. (f) Glue the brain block onto an angled plastic plate. (g) Make a dors...
Name | Company | Catalog Number | Comments |
Isoflurane | Halocarbon Products Corporation | NDC 12164-002-25 | 4% |
aCSF (total:1 L): | |||
D(+)-Glucose | MERCK | 1.08337.1000 | 10 mM |
Sodium hydrogen carbonate | MERCK | 1.06329.0500 | 25 mM |
Sodium chloride | MERCK | 1.06404.1000 | 124 mM |
(+)-Sodium L-ascorbate, >=98% | SIGMA | A4034-100G | 0.15 g/2 c.c |
Magnesium sulfate, anhydrous, ReagentPlus | SIGMA | M7506-500G | 2 mM |
Calcium chloride dihydrate | MERCK | 1.02382.1000 | 2 mM |
Sodium dihydrogen phosphate monohydrate | MERCK | 1.06346.1000 | 1 mM |
Potassium chloride | May & Baker LTD Dagenham England | MS 7616 | 4.4 mM |
(+)-Bicuculline | TOCRIS | 130 | 5 µM in aCSF |
4-Aminopyridine | TOCRIS | 940 | 250 µM in aCSF |
Vibratome | Vibratome | Series 1000 | Block slicing into 500 µm thick slices |
Multielectrode array (MEA) probes: 6 x 10 planar MEA | Multi Channel Systems | 60MEA500/30iR-Ti-pr MEAS 6x10 | electrode diameter, 30 µm; electrode spacing, 500 µm; impedance, 50 kΩ at 200 Hz |
Multielectrode array (MEA) probes: 8 x 8 MEA | Ayanda Biosystems | 60MEA200/10iR-Ti-pr MEAS 8x8 | pyramidal-shaped electrode; diameter, 40 µm; tip height, 50 µm; electrode spacing, 200 µm; impedance, 1,000 kΩ at 200 Hz |
A 60-channel amplifier was used with a band-pass filter set between 0.1 Hz and 3 KHz at 1,200X amplification | Multi-Channel Systems | MEA-1060-BC | |
MC Rack software at a 10 KHz sampling rate | Multi-Channel Systems | Software for data collect and recordings | |
control of a pulse generator | Multi-Channel Systems | STG 1002 | |
slice anchor kits and hold-downs | Warner Instruments | SHD-26H/10; WI64-0250 | |
Peristaltic Pump-minipuls3 | Gilsom | MINIPULS3 | perfusion rate : 8 ml/min |
Isolated stimulator | A-M Systems | Model 2100 | intensity of ±350 μA , duration of 200 μsec |
Tungsten electrode | A-M Systems | 575300 | placed in thalamus |