Aby wyświetlić tę treść, wymagana jest subskrypcja JoVE. Zaloguj się lub rozpocznij bezpłatny okres próbny.
This video demonstrates the procedure for concurrent recordings of co-localized electroencephalography (EEG) and local field potentials (LFPs) in an anesthetized rat. The process involves preparing the rat and attaching stimulating electrodes to its whisker pads. An EEG spider electrode is placed on the rat's skull for surface EEG measurements. At the same time, a multi-channel microelectrode is inserted into a specific brain region through a burr hole in the skull to record neural activity from a localized brain area.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Co-localized EEG/LFP Setup
Figure 1: General setup for concurrent EEG/LFP recording. (A) The setup consists of a modified nose cone for ease of whisker pad stimulation under isoflurane anesthesia, two stimulating electrodes inserted into the whisker pad, a spider electrode positioned on the skull above the barrel cortex contra-lateral to the stimulating electrodes, a multi-channel microelectrode inserted i...
Name | Company | Catalog Number | Comments |
Female Lister Hood rats | Charles Rivers | ||
Spider electrode | Unimed Electrode Supplies Ltd | SCS24-426 | |
EEG paste: Ten20 | Unimed Electrode Supplies Ltd | 10-20-S | |
Stereotaxic holder with dual micromanipulator arms: Dual Manipulator Stereotaxic Frame with 18° Ear Bars | WPI (World Precision Instruments) | 502603 | |
Stainless steel stimulating electrodes | PlasticsOne | E363/1/SPC | |
Isolated current stimulator | Made in House | ||
16-channel micro-electrode, 100 μm spacing, area of each site 177 μm2 | NeuroNexus | A1x16-10mm-100-177-A16 | |
16-channel acute headstage | Tucker David Technologies Inc., TDT | RA16AC-Z | |
Pre-Amplifier: Z-Series 64-Channel Neuro-Digitizing Preamp | TDT | PZ5-64 | |
Passive signal splitter: 32-Channel Splitter Box for PZ5 | TDT | S-BOX_PZ5 | |
Data acquisition unit: RZ2 BioAmp Processor. Z-Series 4-DSP ultra high performance processor | TDT | RZ2-4 | |
Isoflurane | National Vet Services Limited | 50878 | |
Small animal isoflurane anaesthetic system | WPI | EZ-B800A | |
Thermostatic heating pad: Rat Blanket System 230V | Harvard Apparatus UK | 50-7221-F | |
Ophthalmic ointment: Optixcare eye lube | Viovet | 203865 | |
Faraday cage | Newport Corporation | VIS-FDC-3600 | |
Vibration isolation workstation: Vision IsoStation | Newport Corporation | M-VIS3660-RG4-325A | |
Oximeter Control Unit and sensor: MouseOxPlus, Starr Life Sciences Corp. | WPI | O15001 | |
Transparent soft nose cone: Microflex Non-Rebreathing Unit with a Rat Nosecone | WPI | EZ-103A |
This article has been published
Video Coming Soon
Source: Kang, S., et al. Concurrent Recording of Co-localized Electroencephalography and Local Field Potential in Rodent. J. Vis. Exp. (2017).
Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone