Entrar

Kyoto Prefectural University of Medicine

4 ARTICLES PUBLISHED IN JoVE

image

Behavior

Clinical-oriented Three-dimensional Gait Analysis Method for Evaluating Gait Disorder
Masahiko Mukaino 1, Kei Ohtsuka 2, Hiroki Tanikawa 2, Fumihiro Matsuda 2, Junya Yamada 3, Norihide Itoh 4, Eiichi Saitoh 1
1Department of Rehabilitation Medicine, School of Medicine, Fujita Health University, 2Faculty of Rehabilitation, School of Health Science, Fujita Health University, 3Department of Rehabilitation, Fujita Health University Hospital, 4Department of Advanced Rehabilitation Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine

In this study, a clinician-friendly three-dimensional gait analysis method, which was designed to be performed in the rehabilitation clinic, is presented. The method consists of a simplified measurement method and intuitive figures to facilitate clinicians' understanding of the results.

image

Medicine

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Toshiaki Numajiri 1, Daiki Morita 2, Hiroko Nakamura 3, Ryo Yamochi 1, Shoko Tsujiko 4, Yoshihiro Sowa 1
1Department of Plastic and Reconstructive Surgery, Kyoto Prefectural University of Medicine, 2Department of Plastic and Reconstructive Surgery, Showa University Fujigaoka Hospital, 3Department of Plastic and Reconstructive Surgery, Fukuchiyama City Hospital, 4Department of Plastic and Reconstructive Surgery, Saiseikai Shiga Hospital

Methods for designing a computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guide are shown. Cutting planes are separated, united, and thickened to easily visualize the necessary bone transfer. These designs can be three-dimensional printed and checked for accuracy.

image

Bioengineering

A New Ex Vivo Model for the Evaluation of Endoscopic Submucosal Injection Material Performance
Ryohei Hirose 1,2, Tomo Daidoji 2, Yuji Naito 1, Osamu Dohi 1, Naohisa Yoshida 1, Hiroaki Yasuda 1, Hideyuki Konishi 1, Takaaki Nakaya 2, Yoshito Itoh 1
1Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, 2Department of Infectious Diseases, Graduate School of Medical Science, Kyoto Prefectural University of Medicine

We developed a new ex vivo model that applies constant tension to the porcine gastric specimen. This development made it possible to evaluate the performance (the height and duration of the submucosal elevation) of various SIMs accurately.  The detailed setup methodology of this new model is explained.

image

Developmental Biology

In vitro Neuromuscular Junction Induced from Human Induced Pluripotent Stem Cells
Chuang-Yu Lin 1, Michiko Yoshida 1,2, Li-Tzu Li 3, Megumu K. Saito 1
1Department of Clinical Application, Center for iPS Cell Research and Application (CiRA), Kyoto University, 2Department of Pediatrics, Kyoto Prefectural University of Medicine, 3Graduate Institute of Clinical Medicine, Taipei Medical University

Here we provide a protocol to generate in vitro NMJs from human induced pluripotent stem cells (iPSCs). This method can induce NMJs with mature morphology and function in 1 month in a single well. The resulting NMJs could potentially be used to model related diseases, to study pathological mechanisms or to screen drug compounds for therapy.

JoVE Logo

Privacidade

Termos de uso

Políticas

Pesquisa

Educação

SOBRE A JoVE

Copyright © 2024 MyJoVE Corporation. Todos os direitos reservados