AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The two-phase supply system is less common, and the three-wire system incorporates two voltage sources out of phase with each other by 90 degrees.

The three-phase, four-wire system is most prevalent in industrial applications. This system comprises three AC sources that are identical in amplitude and frequency but have a phase difference of 120 degrees between each other. The loads in such a system can be connected in either a Y (star) configuration or a delta (Δ) configuration.

The advantage of three-phase circuits lies in their efficiency and stability. They deliver power with lower pulsation than single-phase systems, resulting in smoother power transmission and minimizing vibrations—a crucial factor for industrial machinery like induction motors. Another benefit is the reduced amount of conductor material required to transmit a given amount of power, which renders three-phase systems more cost-effective than their single-phase counterparts.

The relationship between the line and phase voltages and currents in Y-connected three-phase systems is given by:

Equation 1

Equation 2

And for Δ-connected systems:

Equation 3

Equation 4

These equations show the relationship between line-to-line voltages and currents with those across each phase, which is essential when calculating the total power in three-phase systems. The total power for both Y and Δ connections can be found using:

Equation 5

where ϕ is the power factor angle, which affects power transmission efficiency.

Tags

Three phase CircuitsAC Power DistributionSingle phaseTwo phaseThree phase SystemsVoltage SourcesY ConfigurationDelta ConfigurationPower EfficiencyPower TransmissionIndustrial ApplicationsInduction MotorsConductor MaterialLine to line VoltagesPower Factor Angle

Do Capítulo 8:

article

Now Playing

8.1 : Three-Phase Circuits

Three-Phase Circuits

341 Visualizações

article

8.2 : Generation of Three-Phase Voltage

Three-Phase Circuits

295 Visualizações

article

8.3 : Three-Phase Voltages

Three-Phase Circuits

194 Visualizações

article

8.4 : The Y-to-Y Circuit

Three-Phase Circuits

347 Visualizações

article

8.5 : The Y-to-Delta Circuit

Three-Phase Circuits

358 Visualizações

article

8.6 : The Delta-to-Delta Circuit

Three-Phase Circuits

442 Visualizações

article

8.7 : The Delta-to-Y Circuit

Three-Phase Circuits

269 Visualizações

article

8.8 : Power in a Three-Phase Circuit

Three-Phase Circuits

247 Visualizações

article

8.9 : Power Distribution in Three-phase and Single Phase Circuits

Three-Phase Circuits

245 Visualizações

article

8.10 : Line Loss

Three-Phase Circuits

214 Visualizações

article

8.11 : Reducing Line Loss

Three-Phase Circuits

127 Visualizações

JoVE Logo

Privacidade

Termos de uso

Políticas

Pesquisa

Educação

SOBRE A JoVE

Copyright © 2025 MyJoVE Corporation. Todos os direitos reservados