JoVE Logo

Entrar

The design of residential plumbing systems requires carefully evaluating water demand, flow rates, and pressure dynamics to ensure both efficiency and reliability. The nature of water flow within pipes is defined by its Reynolds number, which classifies flow as either laminar (smooth) or turbulent.

Equation 1

This dimensionless value depends on factors such as water velocity and pipe. Residential plumbing systems are designed to meet specific water demand and flow rate requirements based on occupancy and fixture needs.

Determining the nature of water flow — laminar or turbulent — requires calculating the Reynolds number, which depends on variables like pipe diameter and water velocity. In residential settings, flow is often turbulent, leading to higher energy loss due to friction, which impacts system efficiency. Energy losses, or head losses, arise as water moves through pipes. These losses are classified as either major or minor. Major losses from friction along pipe walls are calculated using the Darcy-Weisbach equation.

Equation 2

The Darcy-Weisbach equation requires a friction factor, which is obtained from the Moody chart. This chart accounts for pipe roughness and flow characteristics, which significantly affect turbulent flow friction levels. Minor losses, in contrast, are caused by fittings, bends, and valves, each of which contributes resistance to flow. Each fitting is assigned a loss coefficient that quantifies its resistance and is factored into the total head loss.

Equation 3

By adding major and minor losses, the overall head loss can be determined and managed so as to maintain adequate pressure, avoiding potential leaks or damage. Flow measurement devices like Venturi or orifice meters ensure the plumbing system provides the necessary flow rates. These meters measure flow rates by detecting pressure differences across constrictions in the pipe, confirming that water flow meets design specifications and household needs.

Tags

Residential Plumbing SystemWater DemandFlow RatesPressure DynamicsReynolds NumberLaminar FlowTurbulent FlowEnergy LossHead LossDarcy Weisbach EquationFriction FactorMoody ChartPipe RoughnessMinor LossesFlow Measurement DevicesVenturi Meter

Do Capítulo 21:

article

Now Playing

21.13 : Design Example: Designing a Residential Plumbing System

Flow in Pipes

74 Visualizações

article

21.1 : General Characteristics of Pipe Flow I

Flow in Pipes

459 Visualizações

article

21.2 : General Characteristics of Pipe Flow II

Flow in Pipes

437 Visualizações

article

21.3 : Laminar Flow

Flow in Pipes

367 Visualizações

article

21.4 : Laminar Flow: Problem Solving

Flow in Pipes

62 Visualizações

article

21.5 : Turbulent Flow

Flow in Pipes

66 Visualizações

article

21.6 : Turbulent Flow: Problem Solving

Flow in Pipes

46 Visualizações

article

21.7 : Major Losses in Pipes

Flow in Pipes

318 Visualizações

article

21.8 : Minor Losses in Pipes

Flow in Pipes

301 Visualizações

article

21.9 : Single Pipe Systems

Flow in Pipes

54 Visualizações

article

21.10 : Multiple Pipe Systems

Flow in Pipes

78 Visualizações

article

21.11 : Pipe Flowrate Measurement

Flow in Pipes

71 Visualizações

article

21.12 : Pipe Flowrate Measurement: Problem Solving

Flow in Pipes

73 Visualizações