To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:

18094_Equation_1_1_.svg

Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by dividing the area by the perimeter. Select an appropriate Manning’s roughness coefficient based on the surface material of the channel. Apply Manning’s equation by substituting the hydraulic radius, channel slope, and roughness coefficient to find the flow velocity. Finally, calculate the flow rate by multiplying the flow velocity with the cross-sectional area. Always use consistent units throughout the process.

Do Capítulo 23:

article

Now Playing

23.3 : Uniform Depth Channel Flow: Problem Solving

Open Channel Flow

30 Visualizações

article

23.1 : Energy Considerations in Open Channel Flow

Open Channel Flow

33 Visualizações

article

23.2 : Uniform Depth Channel Flow

Open Channel Flow

31 Visualizações

article

23.4 : Gradually Varying Flow

Open Channel Flow

15 Visualizações

article

23.5 : Rapidly Varying Flow

Open Channel Flow

22 Visualizações

article

23.6 : Hydraulic Jump

Open Channel Flow

19 Visualizações

article

23.7 : Hydraulic Jump: Problem Solving

Open Channel Flow

15 Visualizações

article

23.8 : Weir

Open Channel Flow

9 Visualizações

article

23.9 : Weir: Problem Solving

Open Channel Flow

17 Visualizações

article

23.10 : Underflow Gates

Open Channel Flow

18 Visualizações

article

23.11 : Design Example: Design of an Irrigation Channel

Open Channel Flow

25 Visualizações

JoVE Logo

Privacidade

Termos de uso

Políticas

Pesquisa

Educação

SOBRE A JoVE

Copyright © 2025 MyJoVE Corporation. Todos os direitos reservados