Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always connected to the ground, is one of the sides of the line. The ground is a real electrode driven into the Earth's surface in houses.

The power supply is constantly connected in parallel with the numerous bulbs, motors, and other devices that need to be powered. If appliances were wired in series, turning off one would turn off the others.

The resistance of the wires limits the maximum current available from an individual circuit. Fuses and circuit breakers protect against overheating and overloading of circuits. A fuse has a link made of a lead-tin alloy with an extremely low melting temperature; when the current exceeds the rated current, the link melts and breaks the circuit. An electromechanical device known as a circuit breaker serves the same purpose by tripping the breaker and cutting off the circuit when the current exceeds a specific limit. The advantage of circuit breakers over blown fuses is that they can be reset after being triggered.

A short circuit results from contact between the line's hot and neutral sides. Such a situation, which can be brought on by faulty insulation or mechanical malfunctions, offers a very low-resistance current path, allowing a huge current. If this current is not cut off by a fuse or circuit breaker, it would quickly melt the wires and ignite their insulation. A damaged wire obstructing the current route and causing an open circuit is similarly risky. The possibility of sparking at the site of sporadic contact makes this dangerous. According to accepted wiring practices, only the hot side of the line should have a fuse or breaker, as hot/live wires supply the current to operate the appliances.

Теги

Household WiringElectrical SafetyThree wire LineNeutral ConductorHot Wires240 V AppliancesCircuit ProtectionFusesCircuit BreakersShort CircuitOpen CircuitWiring PracticesCurrent LimitResistance Of Wires

Из главы 27:

article

Now Playing

27.18 : Household Wiring And Electrical Safety

Direct-Current Circuits

1.0K Просмотры

article

27.1 : Электродвижущая сила

Direct-Current Circuits

3.9K Просмотры

article

27.2 : Резисторы в последовательности

Direct-Current Circuits

4.4K Просмотры

article

27.3 : Параллельные резисторы

Direct-Current Circuits

4.3K Просмотры

article

27.4 : Комбинация резисторов

Direct-Current Circuits

2.3K Просмотры

article

27.5 : Правила Кирхгофа

Direct-Current Circuits

4.2K Просмотры

article

27.6 : Правила Кирхгофа: применение

Direct-Current Circuits

1.3K Просмотры

article

27.7 : Батарея постоянного тока

Direct-Current Circuits

697 Просмотры

article

27.8 : Несколько источников напряжения

Direct-Current Circuits

999 Просмотры

article

27.9 : Гальванометр

Direct-Current Circuits

2.0K Просмотры

article

27.10 : Амперметр

Direct-Current Circuits

1.9K Просмотры

article

27.11 : Вольтметр

Direct-Current Circuits

1.1K Просмотры

article

27.12 : Потенциометр

Direct-Current Circuits

429 Просмотры

article

27.13 : Мост Уитстона

Direct-Current Circuits

382 Просмотры

article

27.14 : Рассеиваемая мощность в цепи: решение проблемы

Direct-Current Circuits

943 Просмотры

See More

JoVE Logo

Исследования

Образование

О JoVE

Авторские права © 2025 MyJoVE Corporation. Все права защищены