Войдите в систему

Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.

A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.

Equation1

Interestingly, this equation's solution comprises both transient and steady-state responses. The transient response gradually diminishes over time, exhibiting similarities to the source-free series RLC circuit solutions under different damping conditions. If the damping factor surpasses the resonant frequency, the response becomes overdamped.

Equation2

When these two factors match, the response is critically damped.

Equation3

The response turns underdamped if the damping factor is less than the resonant frequency.

Equation4

The steady-state response corresponds to the final inductor current, aligning with the source current. Determining the constants involved relies on the initial conditions of the circuit.

Notably, only the transient response remains when the input source current is eliminated. Parallel RLC circuits find extensive applications, particularly in communications networks and filter designs. Understanding their behavior under different damping scenarios contributes to adequate surge protection and circuit design in practical settings.

Теги
Parallel RLC CircuitsSurge ProtectorsCircuit AnalysisVoltage SpikesDC Input SourceStep ResponseKirchhoff s Current LawDifferential EquationTransient ResponseSteady state ResponseDamping FactorResonant FrequencyCritically DampedUnderdampedCommunications NetworksFilter Designs

Из главы 5:

article

Now Playing

5.11 : Parallel RLC Circuits

First and Second-Order Circuits

650 Просмотры

article

5.1 : First-Order Circuits

First and Second-Order Circuits

1.1K Просмотры

article

5.2 : RC Circuit without Source

First and Second-Order Circuits

785 Просмотры

article

5.3 : RC Circuit with Source

First and Second-Order Circuits

731 Просмотры

article

5.4 : RL Circuit without Source

First and Second-Order Circuits

720 Просмотры

article

5.5 : RL Circuit with Source

First and Second-Order Circuits

587 Просмотры

article

5.6 : Design Example: Frog Muscle Response

First and Second-Order Circuits

155 Просмотры

article

5.7 : Second-Order Circuits

First and Second-Order Circuits

1.1K Просмотры

article

5.8 : Series RLC Circuit without Source

First and Second-Order Circuits

878 Просмотры

article

5.9 : Types of Responses of Series RLC Circuits

First and Second-Order Circuits

669 Просмотры

article

5.10 : Series RLC Circuit with Source

First and Second-Order Circuits

249 Просмотры

article

5.12 : Second-order Op Amp Circuits

First and Second-Order Circuits

200 Просмотры

article

5.13 : Design Example: Underdamped Parallel RLC Circuit

First and Second-Order Circuits

186 Просмотры

JoVE Logo

Исследования

Образование

О JoVE

Авторские права © 2025 MyJoVE Corporation. Все права защищены