There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The monochromator consists of a rapidly rotating beam chopper that alternates the sample and reference beams before they reach a diffraction grating. Next, the radiation passes through the thermocouple detector that measures the ratio between the two beams' intensities. The signal from the detector is amplified, and the resulting spectrum is drawn using the recorder. Dispersive IR spectrometers record the spectrum in the frequency domain, meaning the spectrum is captured as the frequency of the radiation changes with the rotation of the diffraction grating.
In an FTIR spectrometer, the radiation produced by the source is passed through a beam splitter. A beam splitter is a mirror placed at an angle of 45° to the incoming radiation and separates the beam into deflected and undeflected radiations. These radiations are later allowed to fall on fixed and moving mirrors. It is important to note that the motion of the two mirrors changes the path length of the beams, and the radiation reflected by the mirrors is combined in the beam splitter. Thus, the produced combined beam contains both constructive and destructive interference patterns due to differences in the path length of the radiations.
The resulting combined beam, called an interferogram, is passed through the detector. The detector detects the interferogram modified by the sample, and the FT process separates the individual absorption frequency from the interferogram.
FTIR spectrometers are preferred over dispersive IR spectrometers due to their faster operation and greater sensitivity.
From Chapter 13:
Now Playing
Molecular Vibrational Spectroscopy
824 Views
Molecular Vibrational Spectroscopy
1.0K Views
Molecular Vibrational Spectroscopy
1.5K Views
Molecular Vibrational Spectroscopy
841 Views
Molecular Vibrational Spectroscopy
681 Views
Molecular Vibrational Spectroscopy
498 Views
Molecular Vibrational Spectroscopy
576 Views
Molecular Vibrational Spectroscopy
795 Views
Molecular Vibrational Spectroscopy
629 Views
Molecular Vibrational Spectroscopy
552 Views
Molecular Vibrational Spectroscopy
560 Views
Molecular Vibrational Spectroscopy
519 Views
Molecular Vibrational Spectroscopy
531 Views
Molecular Vibrational Spectroscopy
635 Views
Molecular Vibrational Spectroscopy
692 Views
See More
Copyright © 2025 MyJoVE Corporation. All rights reserved