Laminar flow occurs when a fluid moves smoothly in parallel layers with minimal mixing and turbulence. In fluid mechanics, ensuring laminar flow within a pipe is essential for precise control of flow characteristics, especially in engineering applications. The key factor in determining whether flow remains laminar is the Reynolds number, a dimensionless quantity that depends on the fluid's velocity, density, viscosity, and the pipe's diameter. A Reynolds number of 2100 or lower indicates laminar flow, while higher values lead to turbulence.
For air flowing through a pipe at standard atmospheric conditions and a given mass flow rate, the velocity of the fluid must be controlled to maintain laminar conditions. Since velocity depends on the flow rate and the cross-sectional area of the pipe, the pipe diameter plays a crucial role. By substituting the velocity expression into the Reynolds number formula and solving for the diameter, it is possible to determine the minimum required pipe size.
Using standard values for air density and viscosity at 300 Kelvin, the volumetric flow rate can be computed. This, in turn, allows for the calculation of the necessary pipe diameter. To ensure a Reynolds number of 2100 or lower, the minimum allowable diameter for the pipe is found to be approximately 0.46 meters. This calculation ensures that the flow remains smooth and predictable, avoiding turbulence that could disrupt performance.
From Chapter 21:
Now Playing
Flow in Pipes
28 Views
Flow in Pipes
55 Views
Flow in Pipes
63 Views
Flow in Pipes
45 Views
Flow in Pipes
33 Views
Flow in Pipes
16 Views
Flow in Pipes
53 Views
Flow in Pipes
48 Views
Flow in Pipes
23 Views
Flow in Pipes
29 Views
Flow in Pipes
34 Views
Flow in Pipes
31 Views
Flow in Pipes
44 Views
Copyright © 2025 MyJoVE Corporation. All rights reserved