Method Article
Array CGH for the detection of genomic copy number variants has replaced G-banded karyotype analysis. This paper describes the technology and its application in a diagnostic service laboratory.
Array CGH for the detection of genomic copy number variants has replaced G-banded karyotype analysis. This paper describes the technology and its application in a clinical diagnostic service laboratory. DNA extracted from a patient’s sample (blood, saliva or other tissue types) is labeled with a fluorochrome (either cyanine 5 or cyanine 3). A reference DNA sample is labeled with the opposite fluorochrome. There follows a cleanup step to remove unincorporated nucleotides before the labeled DNAs are mixed and resuspended in a hybridization buffer and applied to an array comprising ~60,000 oligonucleotide probes from loci across the genome, with high probe density in clinically important areas. Following hybridization, the arrays are washed, then scanned and the resulting images are analyzed to measure the red and green fluorescence for each probe. Software is used to assess the quality of each probe measurement, calculate the ratio of red to green fluorescence and detect potential copy number variants.
It has been known for many years that deletions or extra copies of chromosomal segments cause intellectual disability, dysmorphism and congentical malformations, and in some cases cause genetic syndromes1. However, the only technology available until the mid-2000s for the genome-wide detection of these changes was G-banded chromosome analysis, which has a resolution of around 5-10Mb, depending on the region and nature of the imbalance, and which cannot detect abnormal chromosomes where material has been replaced by a region from a different chromosome with the same banding pattern. Ancillary cytogenetic techniques such as fluorescence in situ hybridization and multiplex ligation-specific probe amplification have been available for the interrogation of specific loci, in cases of suspected specific syndromic imbalance, but it was not until the introduction of array comparative genomic hybridization (array CGH) into routine clinical diagnostic service2-5 that genome-wide detection of copy number variants (CNVs) became possible at a greatly increased resolution (typically around 120kb). Clinical service work alongside research studies have shown that CNVs for some regions are widespread in the normal population6-7, whilst other CNVs, previously undetectable, are associated with neurodisabilities such as autism and epilepsy8-11.
The protocol described in this paper is used in our UK National Health Service (NHS) clinical diagnostic laboratory; we use novel hybridization strategies, batch testing and robotics to minimize cost in this state-funded service.
Prior to the protocol detailed below, high quality DNA should be extracted from the appropriate starting material, commonly blood, cultured cells or tissue samples. Spectrophotometry can be used to measure concentration (should be >50 ng/ul) and check 260:280 absorbance ratios (should be 1.8-2.0). Gel electrophoresis can be used to check that the DNA is of high molecular weight without significant degradation.
This protocol is designed for higher throughput laboratories that are labeling 96 samples per run using automated liquid handling robotics. However, it may be adapted for lower throughput labs without automation.
1. Labelling Reaction
2. Removal of Unincorporated Nucleotides
3. Combine Hyb Pairs
4. Hybridization
5. Washing and Scanning Slides
Each probe on a hybridized array is visualized as a mixture of red and green fluorochromes (see Figure 1). The ratio of red to green fluorescent signal for each probe is quantified by the scanner and the associated software plots these as log2 ratios according to their genomic position, and identifies regions falling outside preset boundaries. The resulting array traces allow interpretation of regions identified as genomically unbalanced. For instance, the trace from a child with Williams syndrome, a rec...
Array CGH will not detect balanced rearrangements or ploidy abnormalities such as triploidy. Furthermore, low level mosaic imbalances may not be detected. However, array CGH has a higher resolution for CNV detection than G-banded chromosome analysis which it has replaced in many cytogenetics laboratories. It is therefore the current gold standard for genome-wide CNV detection. It may be replaced by next-generation sequencing technologies in the future but currently, their cost and the technical complexities associated wi...
The authors have nothing to disclose.
The authors have no acknowledgements.
Name | Company | Catalog Number | Comments |
CGH microarray 8 x 60K | Agilent | G4126 | |
Array CGH wash buffers | Agilent | 5188-5226 | |
Array CGH hybridisation buffer | Agilent | 5188-5380 | |
Minelute purification kit | Qiagen | 28006 | |
Array CGH labelling kit | Enzo | ENZ-42672-0000 |
Request permission to reuse the text or figures of this JoVE article
Request PermissionThis article has been published
Video Coming Soon
Copyright © 2025 MyJoVE Corporation. All rights reserved
We use cookies to enhance your experience on our website.
By continuing to use our website or clicking “Continue”, you are agreeing to accept our cookies.