Summary

We describe the procedure for real-time monitoring of blood flow in vascular grafts using indocyanine green (ICG), a near-infrared (NIR) dye, and a portable near-infrared navigation (NAVI) detectible camera system. The flow of dye in vascular grafts and the camera efficiency have been compared with Doppler and cine-angiography procedures.

Abstract

Vascular grafting failures are often attributed to inadequate anastomotic perfusion assessments. If successful, vascular anastomosis can be rapidly confirmed through the visualization of continuous blood flow upon completion of the grafting process. Surgeons can then minimize graft failures, thus decreasing morbidity in a cost-effective manner. Fluorescence image-guided surgery using near-infrared (NIR) dye is one of the methods that can be performed to monitor grafting success. To address the current logistical challenges and costs of these systems, a compact camera system was used for intraoperative fluorescence real-time NIR imaging. Combined with benchtop experiments, a swine model was used to demonstrate the procedure of using a near-infrared navigation system (NAVI) to visualize grafted vessels in vivo. This was done by performing bilateral arteriovenous grafts and imaging intravenously injected ICG as it circulated through the grafted vessels. The fluorescent images obtained by NAVI were corroborated with Doppler flow measurements and cine-angiography, the current gold standard for the evaluation of vascular grafts.

Introduction

Intraoperative assessments of blood flow following arterial or venous grafting, as well as direct visualization methods evaluating anastomosis, allow surgeons to make immediate decisions on the likelihood of success or failure, allowing for repair, if needed1,2. Techniques frequently employed are fluoroscopic angiography3, direct visualization, palpation of pulsatile flow, pulse oximetry2, Doppler ultrasound4, transit time flowmetry5,6,7, computed....

Protocol

Animal studies were performed following approval from the University of Missouri Animal Care and Use Committee. The University of Missouri is USDA-licensed and AAALAC-International accredited.

1. Pre-operation procedure

  1. Obtain a domestic Yorkshire/large white pig (4 months old; 57 kg) one day prior to the study and provide water ad libitum.
  2. Sedate the pig with 5 mg/kg Telazol and 2.2 mg/kg xylazine. Provide 3-4% isoflurane by nose cone until the pig can be intuba.......

Representative Results

Optimization of the Concentration of ICG

The concentration of ICG required to produce optimal fluorescent images was determined using the following procedure. Different concentrations of ICG solutions ranging from 1.29 to 258 µM were prepared in microcentrifuge tubes and placed on a stand. The NIR light source and the camera were placed at a constant distance from the dye (i.e., 18 and 31 in, respectively, from the st.......

Discussion

Development of NAVI for ICG Imaging Applications

NIR-based fluorescence imaging is emerging as a simple alternative procedure for intraoperative imaging, demonstrating significant benefits by: (1) eliminating the radiation exposure required by fluoroscopy and computed tomography and (2) reducing the surgical time, thus decreasing per-patient costs while maintaining efficacy and increasing safety. In this paper, we demonstrated the procedure for using NAVI to perform fluorescence imaging (using IC.......

Acknowledgements

The authors acknowledge Neff Sherri and Jan Ivey for their help during the study. Kannan, Tharakan, and Upendran acknowledge the Mizzou Advantage Grant, Ellis Fischel Cancer Center Grant, and Coulter Foundation for providing financial support.

....

Materials

NameCompanyCatalog NumberComments
TelazolZoetisReconstitute with sterile water prior to use
Xylazine (AnaSed)AKORN Animal Health
0.9% NaClAbbott
Indocyanine greenAKRON
HeparinBaxter
Visipaque (iodixanol)GE Healthcare564v
Guide catheterBoston Scientific
LED 770-03AU, 18 mWRoithner Laser Technik GmbH, Wiedner Hauptstrasse, Austria
Short pass filterEdmund optics, Barrington, NJ, USA
NIR imaging  camera (Igen NV20/20-IC)B&H optics, New york, NY, USA
Micropac USB-AVCPT interfaceSabrent, USA
CT instrumentVarian Medical System manufactured by Omega Medical Imaging
TS420 Perivascular Flow Module Transonic Systems Inc., Ithaca, NYTS420 & T402
PR Series Flow Probes Transonic Systems Inc., Ithaca, NY3PSB
Digital Board to Flow moduleADInstruments Inc., Colorado Springs, CO
Lab ChartADInstruments Inc., Colorado Springs, CO

References

  1. Detter, C., et al. Fluorescent cardiac imaging: a novel intraoperative method for quantitative assessment of myocardial perfusion during graded coronary artery stenosis. Circulation. 116, 1007-1014 (2007).
  2. Urbanavicius, L., Pattyn, P., de Putte, D. V., Venskutonis, D.

Explore More Articles

near infrared dyefluorescent imagingvascular graftscarotidnavigation systemcine angiographyindocyanine green

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved