An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous across any boundary; hence the derivative of the vector potential is discontinuous across the boundary.

Consider two linear magnetic media with permeability μ1 and μ2, separated by an interface. The magnetic field intensity in medium 1 at a point P1 has a magnitude H1, and makes an angle α1 with the normal. Similarly, the magnetic field intensity in medium 2 at a point P2 has a magnitude H2, and makes an angle α2 with the normal.

Figure1

The zero divergence of the magnetic field ensures that the normal component of the magnetic field is continuous across the boundary. The magnetic field is proportional to the magnetic field intensity for linear magnetic media. Thus, the boundary conditions for the normal component of the magnetic field intensity are obtained.

Rewriting the normal components of the magnetic field in terms of the angles α1 and α2,

Equation1

Since both media possess finite conductivities, free surface currents do not exist at the interface. Thus, the tangential component of the magnetic field intensity is continuous across the boundary. Again, the tangential components can be rewritten in terms of the angles α1 and α2:

Equation2

Taking the ratio of normal and tangential components, a new expression is derived:

Equation3

This expression is similar to the expression obtained for boundary conditions for two dielectric interfaces, except that the permittivity replaces the permeability.

If the first medium is a non-magnetic medium, like air, and the second one is a magnetic medium, the permeability of the second medium is greater than the permeability of the first medium. Thus, the angle α2 approaches ninety degrees. This implies that, for any arbitrary angle α1 that is not close to zero, the magnetic field in a ferromagnetic medium runs parallel to the interface. If the first medium is ferromagnetic and the second is non-magnetic, α2 approaches zero. This implies that if a magnetic field originates in a ferromagnetic medium, the magnetic flux lines emerge into the air medium in a direction almost normal to the interface.

Tags
Magnetostatic Boundary ConditionsElectric Field DiscontinuityMagnetic Field DiscontinuitySurface ChargeSurface CurrentMagnetic PermeabilityVector PotentialMagnetic MediaMagnetic Field IntensityNormal ComponentTangential ComponentZero DivergenceFinite ConductivitiesFree Surface CurrentsDielectric InterfacesFerromagnetic Medium

From Chapter undefined:

article

Now Playing

Magnetostatic Boundary Conditions

Related Videos

644 Views

article

Magnetic Field due to Moving Charges

Related Videos

6.6K Views

article

Biot-Savart Law

Related Videos

4.7K Views

article

Biot-Savart Law: Problem-Solving

Related Videos

1.8K Views

article

Magnetic Field Due To A Thin Straight Wire

Related Videos

4.0K Views

article

Magnetic Field Due to Two Straight Wires

Related Videos

1.7K Views

article

Magnetic Force Between Two Parallel Currents

Related Videos

2.8K Views

article

Magnetic Field Of A Current Loop

Related Videos

3.6K Views

article

Divergence and Curl of Magnetic Field

Related Videos

2.1K Views

article

Ampere's Law

Related Videos

3.1K Views

article

Ampere's Law: Problem-Solving

Related Videos

3.1K Views

article

Solenoids

Related Videos

2.1K Views

article

Magnetic Field of a Solenoid

Related Videos

3.1K Views

article

Toroids

Related Videos

2.5K Views

article

Magnetic Vector Potential

Related Videos

331 Views

See More

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved