Sign In

8.4 : The Y-to-Y Circuit

In a balanced four-wire wye-to-wye system, the arrangement involves wye-connected sinusoidal voltage sources and loads, connected through a neutral wire that links the neutral nodes of the source and load. The load impedance is connected across each phase of the load. The wye-connected source can be connected to the wye-connected load in four-wire and three-wire arrangements. A three-phase system is considered balanced when the load on each phase is equal, leading to uniform current flow and phase angle across all stages. On the other hand, in an unbalanced system, variations in load impedance or source voltages result in unequal line currents.

Analysis of the four-wire wye-wye circuit configuration is relatively straightforward. In this setup, each impedance of the three-phase load is connected directly across its respective phase voltage from the three-phase source. Assuming a positive phase sequence and balanced conditions, the phase voltages are instrumental in analyzing the system. These phase voltages directly influence the voltages across each load impedance.

Equation 1

Equation 2

Equation 3

The current in the wire connecting the neutral node of the source to the neutral node of the load is:

Equation 4

Kirchhoff's Voltage Law, when applied to each phase of a balanced three-phase circuit, confirms that the sum of the voltages around any closed loop is zero. This leads to line currents of equal magnitude but with 120-degree phase shifts between them. These currents effectively sum to zero at any point, which justifies why the neutral wire carries no current under balanced conditions.

In an unbalanced wye-to-wye system, variations in load impedance or source voltages result in unequal line currents. Each phase in the system is treated as a single-phase circuit to calculate its line current. However, the currents for the remaining phases require individual analysis rather than deduction solely based on the sequence of phases, as each phase may be influenced uniquely by its specific electrical conditions.

Tags
Y to Y CircuitBalanced SystemWye connectedNeutral WireLoad ImpedancePhase VoltageThree phase SystemUnbalanced SystemKirchhoff s Voltage LawLine CurrentsPhase AngleNeutral NodeCurrent Flow

From Chapter 8:

article

Now Playing

8.4 : The Y-to-Y Circuit

Three-Phase Circuits

67 Views

article

8.1 : Three-Phase Circuits

Three-Phase Circuits

84 Views

article

8.2 : Generation of Three-Phase Voltage

Three-Phase Circuits

74 Views

article

8.3 : Three-Phase Voltages

Three-Phase Circuits

42 Views

article

8.5 : The Y-to-Delta Circuit

Three-Phase Circuits

70 Views

article

8.6 : The Delta-to-Delta Circuit

Three-Phase Circuits

135 Views

article

8.7 : The Delta-to-Y Circuit

Three-Phase Circuits

46 Views

article

8.8 : Power in a Three-Phase Circuit

Three-Phase Circuits

48 Views

article

8.9 : Power Distribution in Three-phase and Single Phase Circuits

Three-Phase Circuits

50 Views

article

8.10 : Line Loss

Three-Phase Circuits

60 Views

article

8.11 : Reducing Line Loss

Three-Phase Circuits

34 Views

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2025 MyJoVE Corporation. All rights reserved