Thickness Measurement, Biaxial Tester Setup, and Fiducial Marker Placement
2:48
Preconditioning and Duration Timing
4:51
Biaxial Mechanical Testing
8:48
Results: Representative Displacement-Controlled and Stress Relaxation Protocol Analyses
10:24
Conclusion
副本
This method can provide a better understanding of heart valve biomechanics which can be extremely useful in computational modeling and in the refinement of treatment methods for heart valve disease. This protocol is advantageous compared to other
登录或开始您的免费试用以访问此内容
This protocol involves characterizations of atrioventricular valve leaflets with force-controlled, displacement-controlled, and stress-relaxation biaxial mechanical testing procedures. Results acquired with this protocol can be used for constitutive model development to simulate the mechanical behavior of functioning valves under a finite element simulation framework.